Laserfiche WebLink
FIXED <br />FIXED <br />FIXED <br />FIXED <br />FIXED <br />FIXED <br />SP SP <br />SP <br />SP <br />SPSP <br />ELECTRICAL GENERAL NOTES <br />LIGHTING GENERAL NOTES <br />A. CONNECT EXIT/EMERGENCY/NIGHT FIXTURES TO UNSWITCHED HOT CONDUCTOR AHEAD OF <br />ANY LIGHTING CONTROLS. <br />B. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN AND DETAILS FOR THE LOCATION OF <br />ALL LIGHTING FIXTURES AND ALL OTHER CEILING MOUNTED EQUIPMENT. VERIFY MOUNTING <br />HEIGHTS AND FINISHES WITH ARCHITECT PRIOR TO ROUGH-IN. <br />C. REFER TO THE POWER PLANS FOR LOCATION OF ELECTRICAL EQUIPMENT. <br />D. PROVIDE INDICATED CONDUCTOR SIZE FOR ENTIRE CIRCUIT WHERE CONDUCTOR SIZES <br />ARE SHOWN ON HOMERUNS. <br />E. PROVIDE A DEDICATED NEUTRAL WITH ALL DIMMING SYSTEM CIRCUITS. NO COMMON <br />NEUTRALS SHALL BE ALLOWED. <br />F. PROVIDE (2) ADDITIONAL #12 CONDUCTORS FOR ALL 0-10V DIMMING CIRCUITS. <br />1. JUNCTION BOX ABOVE CEILING FOR HOOD LIGHTS AND EXHAUST HOOD. <br />2. PROVIDE WEATHERPROOF JUNCTION BOX AND TOGGLE TYPE 20A-1P DISCONNECT FOR <br />SIGNAGE. COORDINATE EXACT REQUIREMENTS WITH SIGN CONTRACTOR. VERIFY <br />LOCATION PRIOR TO ROUGH IN. <br />3. PROVIDE LAMP FOR HOOD LIGHT. SUBSTITUTION OF CFL OR INCANDESCENT LAMP IS <br />PROHIBITED. <br />4. LOCATION OF LIGHTING SWITCH BANK. REFER TO SWITCH AND HOOD SUPPRESSION <br />ELEVATION ON SHEET E5.1 FOR ADDITIONAL INFORMATION. <br />5. PROVIDE RECEPTACLE FOR DINING ROOM SIGNAGE. REFER TO ARCHITECTURAL <br />ELEVATIONS FOR EXACT MOUNTING LOCATION <br />6. LED TAPE LIGHTING DRIVER MUST BE INSTALLED INSIDE OF BUILDING DUE TO <br />TEMPERATURE RATING OF DRIVER. REFER TO LED DRIVER MOUNTING DETAIL, SHEET E5.2 <br />7. LIGHTS IN CANOPY PROVIDED BY CANOPY MANUFACTURER. <br />8. EXTERIOR LED TAPE LIGHTING 'TL1'. REFER TO ARCHITECTURAL SHEETS FOR MORE <br />INFORMATION. VERIFY LENGTHS AND DRIVER REQUIREMENTS PRIOR TO INSTALLATION. <br />REFER TO WALL PENETRATION DETAIL, SHEET E5.2. <br />CODED NOTES: <br />A. COORDINATE WORK WITH MECHANICAL, REFRIGERATION AND EQUIPMENT CONTRACTORS, <br />INCLUDING COOLER/FREEZER WORK AND ICE MACHINE CONDENSING UNITS. <br />B. VERIFY ROUGH-IN DIMENSIONS AND POWER REQUIREMENTS WITH KITCHEN EQUIPMENT <br />DISTRIBUTOR PRIOR TO ROUGH-IN. <br />C. PROVIDE FINAL CONNECTIONS WITHIN FRONT COUNTER, COOKCENTER PANEL, REMOTE <br />REFRIGERATION UNITS, AND ICE MACHINE REMOTE UNIT WHEN INSTALLED BY VENDOR. <br />D. VERIFY AVAILABLE FAULT CURRENT AT PRIMARY SERVICE AND COMPATIBILITY WITH <br />MODULAR PANEL SYSTEM. <br />E. ENSURE ADEQUATE CONDUIT SIZE FOR ELECTRICAL AND COMMUNICATION WIRING ON SITE <br />AND INTO BUILDING. <br />F. CIRCUITS MAY BE GROUPED WITHIN COMMON CONDUITS PER NEC REQUIREMENTS UNLESS <br />NOTED OTHERWISE. <br />G. PROVIDE WALL BOX WITH 1/2" CONDUIT WITH PULLSTRING AND NYLON BUSHING STUBBED <br />ABOVE NEAREST ACCESSIBLE CEILING FOR THERMOSTATS, TEMPERATURE SENSORS, <br />CARBON DIOXIDE SENSOR, AND HUMIDISTATS UNLESS OTHERWISE NOTED. <br />H. WIRE ROOF TOP UNIT CONTROL CIRCUIT THROUGH AUXILIARY CONTACTS IN SMOKE <br />DETECTOR AND MAKE ALL FINAL CONNECTIONS. (TYPICAL OF ALL ROOF TOP UNITS) <br />I. COOKCENTER IS ASSEMBLED AND PREWIRED AT THE FACTORY. WIRING IS PROVIDED IN THE <br />PRE- INSTALLED SPLICE BOX, COILED AND TAGGED. A LENGTH OF CONDUIT WITH WIRES IS <br />PROVIDED FOR THE REMOTE CONDENSING ROOFTOP UNIT. RUN POWER FROM THE SPLICE <br />BOX TO THE COOKCENTER PANEL. <br />J. ROOFTOP UNIT IS FACTORY PROVIDED WITH DISCONNECT AND UNPOWERED SERVICE <br />RECEPTACLE. <br />K. IN AREAS WITHOUT CEILINGS OR WHERE ANY CONDUITS, CONDUCTORS, FEEDERS, OR LOW- <br />VOLTAGE WALL EMT CONDUIT CABLING IS VISIBLE, ALL WIRING SHALL BE IN RIGID <br />GALVANIZED STEEL (RGSC) OR THIN WALL EMT CONDUIT. BX, AC, AND MC CABLE ARE NOT <br />PERMITTED. CONDUITS ARE TO BE RUN TIGHT TO DECK EITHER PARALLEL OR <br />PERPENDICULAR TO BUILDING LINES AND ONLY DROP AT POINT OF CONNECTION. JUNCTION <br />BOXES SHALL HAVE CIRCUIT NUMBERS WRITTEN ON THE INSIDE OF THE JUNCTION BOX <br />COVER. <br />L. SEAL ROOF PENETRATIONS PER ROOFING MANUFACTURER'S INSTRUCTIONS. <br />M. COORDINATE WORK ABOVE THE CEILING WITH OTHER TRADES TO PROVIDE THE GREATEST <br />POSSIBLE CLEARANCE.CONDUITS SHALL BE ROUTED IN THE DIRECTION OF THE TRUSSES. <br />N. ONLY EMT CONDUITS ARE ALLOWED IN RECEIVING/DRY STORAGE. <br />O. DEFINITIONS:FURNISH MEANS TO SUPPLY AND DELIVER TO PROJECT SITE, READY FOR <br />INSTALLATION.INSTALL MEANS TO PLAN IN POSITION AND MAKE CONNECTIONS FOR SERVICE <br />OR USE.PROVIDE MEANS TO FURNISH AND INSTALL, COMPLETE AND READY FOR INTENDED <br />USE. <br />A-2 <br />B1 <br />RECESSED CAN LIGHT FIXTURE <br />RECESSED CAN NIGHT LIGHT FIXTURE <br />LED LIGHT FIXTURE <br />LED NIGHT LIGHT FIXTURE <br />CEILING MOUNTED CYLINDER <br />MONO POINT LIGHT FIXTURE <br />EMERGENCY REMOTE EGRESS HEAD <br />CIRCUIT NUMBER <br />FIXTURE SYMBOL <br />OCCUPANCY SENSOR (WALL MOUNTED OR <br />CEILING MOUNTED) <br />SINGLE POLE WALL SWITCH AT 4'-6" A.F.F. <br />EMERGENCY FLOOD LIGHT (WALL MOUNTED OR <br />CEILING SURFACE MOUNTED) <br />DIMMER SWITCH, (LEVITON #IP710-DLZ-WH) <br />LIGHTING LEGEND <br />LED TAPE LIGHT <br />GLOBE PENDANT LIGHT <br />PENDANT LIGHT <br />TRACK HEAD <br />BUILDING MOUNTED DECORATIVE LIGHT <br />LIGHTING TRACK <br />LIGHT FIXTURE SCHEDULE <br />CONTACT WENDY'S APPROVED LIGHTING SUPPLIER <br />UPDATED: 8.26.2022 <br />FIXTURE DESCRIPTION MANUFACTURER FIXTURE NUMBER FIXTURE <br />WATTAGE VOLTAGE <br />A1 LED - RECESSED DOWNLIGHT, T-GRID MOUNTED. 3000K. <br />DIRECT CONNECT LED. WHITE <br />BOLT BEBRK-LED56-BW-3-ECO 12 120 <br />B4 2x4 LED FLAT PANEL LED. 4000K. WHITE <br />BACK OF HOUSE ONLY <br />BOLT BELEDPNL2X4-40W-4K 50 120 <br />EM2B EMERGENCY LIGHT. BLACK. HIGH LUMEN OUTPUT <br />BOLT BELEDR-1B-HL 1.8 120 <br />BEST LIGHTING LEDR-1B-HL 1.8 120 <br />EMERGENSEE SEELEDR-1B-HL 1.8 120 <br />EM2W EMERGENCY LIGHT. WHITE. HIGH LUMEN OUTPUT <br />BOLT BELEDR-1W-HL 1.8 120 <br />BEST LIGHTING LEDR-1W-HL 1.8 120 <br />EMERGENSEE SEELEDR-1W-HL 1.8 120 <br />EX1B <br />EXIT/EMERGENCY LIGHT COMBO, HIGH LUMEN, BLACK, RED <br />LETTERS. REMOTE CAPACITY. FRONT OF HOUSE ONLY. <br />BOLT BELEDCXTEU2RBRCHL 3.7 120 <br />BEST LIGHTING LEDCXTEU2RBRCHL 3.7 120 <br />EX1W EXIT/EMERGENCY LIGHT COMBO, HIGH LUMEN, WHITE, RED <br />LETTERS. REMOTE CAPACITY <br />BOLT BELEDCXTEU2RWRCHL 3.7 120 <br />BEST LIGHTING LEDCXTEU2RWRCHL 3.7 120 <br />EMERGI-LITE ELXN400-R-2LEDR 3.6 120 <br />EX1RB <br />EXTERIOR EMERGENCY LIGHT. BLACK. TWIN LAMP. <br />WEATHER PROOF. <br />BOLT BERHLED2-PWP-MVB 4 120 <br />BEST LIGHTING RHLED2-PWP-MVB 4 120 <br />OS2 WALK IN COOLER / FREEZER MOTION SENSOR KASON 1901A-5 <br />BUILDING LIGHTING - EXTERIOR <br />WP4 EXTERIOR SECURITY LIGHT, INTEGRAL LED WITH PHOTOCELL <br />5000K <br />RAB WPLED26N/PC 26 120 <br />ABB WL-26501PC 26 120 <br />A6 LED - DOWNLIGHT - EXTERIOR . 3000K. DIRECT CONNECT. <br />NICKEL NICOR DLR56-3012-120-3K-NK 19 120 <br />36 120 <br />WITH MINIMUM 90 MIN BATTERY BACKUP <br />WITH MINIMUM 90 MIN BATTERY BACKUP <br />WITH MINIMUM 90 MIN BATTERY BACKUP <br />WITH MINIMUM 90 MIN BATTERY BACKUP <br />WITH MINIMUM 90 MIN BATTERY BACKUP <br />EL-1 LINEAR LED LIGHT BAR- 3" X 48"VICEROY WENS-VCYW48-FLO-L36.0-ZE-UNIV 120 <br />T2 THEATRICAL VERTICAL LED TRACK HEAD, TRACK MOUNT, <br />ART PACK LIGHTS, BLACK, 3500K, THEATRICAL SHADES. 18" <br />EXTENSION ROD <br />CONTECH LIGHTING CTL8061VS35D-B-BD16A <br />18" EXTENSION 10 120 <br />T2T TRACK SYSTEM 2', 4', 6' LENGTH CONTECH LIGHTING LT-2B, LT-4B, LT-6B <br />WB1 WALK-IN COOLER/ FREEZER LIGHT. INTEGRAL LED, NSF <br />RATED, 4000K, WHITE <br />MAXLITE LSV4U23WCSCR 34.2 120 <br />TL1 EXTERIOR LED TAPE LIGHTING SYSTEM. 3500K CONTECH LIGHTING TLT24V35K PACKAGE. CONTACT WENDY'S LIGHTING SUPPLIER <br />P5 UM BRIGHT GLOBE PENDANT. INTEGRAL LED 3500K ARKANSAS LIGHTING 4240P-LED 20 120 <br />P1 FMLWL-LNK-48-ALO4-8SWW2 <br />LED DRIVER <br />4000K, 2000 LUMEN 25 120LITHONIA LIGHTING <br />RT ELA QM T WP 3 120HOLOPHANE LIGHTING <br />MAXLITE RR6119CSW 11 120 <br />B2 2x2 LED FLAT PANEL LED. 4000K. WHITE <br />BACK OF HOUSE ONLY <br />BOLT BELEDPNL2X2-40W-4K 40 120 <br />MAXLITE MLFP22G418WCSCR 30 120 <br />BARRON LPA22-30-4K 30 120 <br />A7 LED - 5" CYLINDER LIGHT, 3000K, INTEGRAL LED, BLACK PROGRESS P5774-31/30K 17 120 <br />01 LIGHTING PLAN <br />SCALE: 1/4" = 1'-0" <br />A1 <br />13 <br />A1 <br />11 <br />A1 <br />11 <br />A1 <br />11 <br />A1 <br />11 <br />A1 <br />11 <br />A1 <br />11 <br />A1 <br />11 <br />A-11 <br />A1 <br />13 <br />A1 <br />13 <br />A1 <br />13 <br />A1 <br />13 <br />A1 <br />13 <br />A1 <br />13 <br />A1 <br />13 <br />A1 <br />13 <br />A7 <br />24 <br />A7 <br />24 <br />24 <br />A7 <br />24 24 24 24 <br />21 <br />A7 <br />24 <br />A7 <br />24 <br />24 <br />A7 <br />24 <br />A7 <br />24 <br />24 <br />24 <br />A-24 <br />A-13 <br />24 <br />A-33 <br />B4 <br />33 <br />B4 <br />33 <br />B4 <br />33 <br />B4 B2 B4 B4 <br />B4 <br />A-12 <br />12 <br />12 <br />12 12 <br />12 <br />12 <br />EX1B <br />EX1B <br />33 <br />EL-1 EL-1 <br />EL-1 EL-1 <br />WP4 <br />WP4 <br />A6 A6 <br />A6 A6 A6 <br />A6 A6 A6 <br />A6 <br />A6 <br />A6 A6 A6 <br />A6 <br />A-2 <br />2 2 <br />2 <br />22 <br />2 <br />2 2 <br />2 2 2 <br />2 2 2 <br />2 <br />2 <br />2 <br />222 <br />33 <br />EM2B <br />EM2B <br />EM2B <br />EM2B <br />EM2B <br />EM2B <br />EM2B <br />EM2B <br />33 <br />33 <br />12 <br />11 <br />11 <br />24 <br />24 <br />24 <br />SWITCH e <br />A7 A7 <br />P1 <br />WB1WB1 <br />A-38 <br />#10 <br />#10 <br />A-38 <br />TL1 <br />#10 <br />A-38 <br />TL1 TL1 <br />OS2 OS2 <br />P5 <br />24 <br />RT <br />EX1B <br />RT <br />RT <br />B4 <br />33 <br />B4 <br />A2 <br />21 <br />21 <br />T2 <br />21 <br />21 <br />T2 <br />21 <br />A-21 <br />SWITCH d <br />24 <br />ROOF <br />ACCESS <br />B4 <br />33 <br />T2 <br />A7 <br />A7 <br />A7 A7 <br />A7 <br />A7 <br />A7 A7 A7 <br />A7 <br />A7 <br />A7 <br />A1 <br />24 <br />21 <br />24 <br />24 24 <br />A7 <br />24 <br />24 <br />24 <br />B2 <br />33 <br />B4 <br />33 <br />SWITCH a <br />SWITCH b <br />SWITCH c <br />A-28 <br />(TYP) <br />(TYP) <br />SHEET NAME <br />SHEET NUMBER <br />SEAL <br />DESCRIPTIONDATEREV. <br />ISSUE DATE: **/**/**** <br />PROJECT NUMBER: ***** <br />DRAWN BY: <br />CHECKED BY: <br />SITE NUMBER: <br />BUILDING TYPE: <br />OWNER: <br />BASE VERSION: <br />DRAWING RELEASE: <br />PROJECT YEAR: <br />ASSET TYPE: <br />CLASSIFICATION: <br />UPGRADE CLASSIFICATION: <br />DESIGN TYPE: <br />2600 <br />S <br />BRISTOL <br />ST <br />SANTA <br />ANA, <br />CA <br />92704 <br />PROJECT TYPE: <br />00000 <br />GLOBAL NEXT GEN 30 <br />FREESTANDING <br />NEW <br />COMPANY/FRANCHISE <br />2022 <br />NEW BUILD <br />2024 <br />GLOBAL <br />SPRING 2023 <br />NEW <br />GLOBAL NEXT GEN 30 <br />E-1.0 <br />LIGHTING PLAN