Laserfiche WebLink
CITY <br />OF SANTA ANA <br />Cy <br />® CODED NOTES. <br />SITE NUMBER: 00000 <br />BASE MDL: GLOBAL NEXT GEN 30 <br />1. INSTALL GREASE EXHAUST HOOD. SUPPORT HOOD PER MANUFACTURE <br />'S INSTALLATION <br />ASSET TYPE: FREESTANDING <br />INSTRUCTIONS. TRANSITION FROM HOOD COLLAR TO DUCT SIZE SHOWN. <br />TWO METHODS <br />LISTED BELOW ARE ALLOWED FOR GREASE DUCTWORK ASSEMBLIES. PL <br />EASE NOTE THAT <br />BOTH OPTIONS REQUIRE CLEANOUT ACCESS DOORS AT EVERY CHANGEIN <br />DUCT DIRECTION <br />I I NEW <br />WITH 3 FOOT CLEARANCE IN FRONT OF ACCESS DOORS. <br />WNER: COMPANY/FRANCHISE <br />1.1. PREFERRED METHOD: FACTORY MANUFACTURED UL2221 LISTED INS <br />EXHAUST DUCT SYSTEM WITH MANUFACTURER CLEANOUT ACCESS <br />ULA E <br />DOO FP E. <br />V R O 02 <br />JAIW <br />SHEET M2.0 FOR ADDITIONAL INFORMATION. COORDINATE WITH GREASE <br />UC <br />MANUFACTURER IF FIRE WRAP IS REQUIRED. <br />UPGRADE CLASSIFICATION: <br />1.2. PROVIDE 16 GAGE CARBON STEEL GREASE EXHAUST DUCTWORKWELDED <br />LIQUID TIGHT <br />UP TO EXHAUST FAN. WRAP GREASE DUCT WITH COMPOSITE GREA <br />E DUCT ENCLOSURE <br />ASSEMBLY PER DETAIL 01/M2.0. GREASE DUCT ENCLOSURE SHALLAVE <br />AT LEAST AN F <br />NEW BUILD <br />OR T RATING OF ONE HOUR. INSTALL EXHAUST DUCT WRAP PER MA <br />UFACTURER'S <br />PROJECT YEAR: XXXX <br />INSTRUCTIONS. PROVIDE "FASTDOOR XL" GREASE DUCT CLEANOUT <br />CCESS DOORS(C.O.D) <br />MANUFACTURED BY THERMAL (OR ANCEAIN <br />9ULENT) T �j <br />N-0 D <br />DESIGN TYPE: GLOBAL <br />DIRECTION IN DUCT. ROVIDE MINIMUM 3FEET CLEEARAMICS <br />FRO <br />T . <br />INSULATE ACCESS DOORS TO MAINTAIN RATINGS OF GREASE DUCT <br />ENCLOSURE PER <br />DRAWING RELEASE: SPRING 2023 <br />FIRE PROTECTION INSULATION MANUFACTURER'S INSTRUCTIONS. <br />Date_ <br />2. PROVIDE COMBINATION AUDIO/VISUAL ALARM AND REMOTE TEST STATI <br />N (SYSTEM SENSOR <br />RTS2). MOUNT 54" ABOVE FINISHED FLOOR AND PROVIDE LABEL NAMEPLIATE <br />WITH 1/2 HEIGHT <br />LETTERING (BLACK ON WHITE) FOR WHICH UNIT IT MONITORS. INSTALLA <br />ION SHALL MEET <br />CRITERIA AS PRESCRIBED IN NFPA 90A AND NFPA 72. <br />3. PROVIDE ROOFTOP UNIT AND CURB COORDINATED WITH STRUCTURE. SHIM UNIT AND CURB <br />LEVEL FOR PROPER CONDENSATE DRAINAGE. PROVIDE FLEXIBLE CONNECTORS ON SUPPLY <br />AND RETURN AIR DUCT CONNECTIONS. TRANSITION TO DUCT SIZES SHOWN. SECURE <br />EQUIPMENT TO CURBS PER MANUFACTURER'S RECOMMENDATIONS AND AS DETAILED. REFER <br />TO SHEET M2.0 FOR ADDITIONAL INFORMATION. <br />4. CONTRACTOR SHALL INSTALL GRIDPOINT/ENERGYBOX THERMOSTATS TO CONTROL ALL HVAC <br />UNITS. CONTRACTOR SHALL INSTALL GRIDPOINT/ENERGYBOX (ZONE SENSING MODULES) IN THE <br />CORRECT HVAC ZONES TO REPORT ZONE TEMPERATURE AND CONNECT TO EACH ZONES <br />THERMOSTAT T1 INPUT AS SHOWN. SENSOR 60" ABOVE FINISHED FLOOR. INSULATE EXTERIOR <br />WALL BEHIND REMOTE SENSORS ON EXTERIOR WALLS AND CAULK WIRE PENETRATION THROUGH <br />WALL. RUN CAT5E CABLE FROM TS150-1 TO TS150-2. LEAVE 8" OF CABLE COILED/ACCESSIBLE IN <br />BOTH REMOTE SENSORS ON EXTERIOR WALLS AND CAULK WIRE PENETRATION THROUGH WALL. <br />5. PROVIDE DUCT MOUNTED SMOKE DETECTOR AND SENSING TUBE, AND INTERLOCK TO SHUT ARM ET DAVIS NEWLOVE & <br />DOWN ROOFTOP UNIT ON DETECTION OF SMOKE, ASSOCIATES, AIA ARCHITECTS <br />6. PROVIDE CURB AND ROOF MOUNTED EXHAUST FAN. ENSURE THAT TOP OF EXHAUST FAN IS 1330 OLYMPIC BLVD. <br />MINIMUM 40" ABOVE ROOF SURFACE. REFER TO SHEET M2.0 FOR ADDITIONAL INFORMATION. SANTA MONICA, CALIFORNIA 90404 <br />7. PROVIDE CURB AND ROOF MOUNTED EXHAUST FAN. REFER TO SHEET M2.0 FOR ADDITIONAL PH 310 452-5533 FAX 310 450-4742 <br />INFORMATION. <br />8. UNDERCUT DOOR 1" FOR TRANSFER AIR. <br />9. LOCATE SMOKE DETECTOR DOWNSTREAM OF RETURN AIR TAP CONNECTIONS. LI & D ENGINEERING <br />^ I G I^ I C C D I^ I G <br />10. PROVIDE DUCTLESS SPLIT SYSTEM AND CONDENSING UNIT. REFER TO SHEET M3.0 <br />FOR SCHEDULE INFORMATION. ENERGY &MECHANICAL SYSTEM CONSULTANT <br />1330 OLYMPIC BOULEVARD, #8 <br />11. CONTRACTOR SHALL INSTALL GRIDPOINT TEMPERATURE PROBES IN EACH HVAC SUPPLY DUCT 1330A LYMPICMONICA, CA. BOULEVARD, <br />TO REPORT DISCHARGE AIR TEMPERATURE AND CONNECT TO EACH ZONES THERMOSTAT T2 <br />90404 <br />INPLILLAS SHOWN. TEL: (310) 452-0575 <br />12. EXPOSED DINING ROOM DUCTWORK AND DIFFUSERS VISIBLE TO THE PUBLIC SHALL BE PAINTED FAX: (310) 450-4742 <br />TO MATCH CEILING. EMAIL: KAVEH@LANDDENGINEERING.COM <br />CONTRACTOR TO MAKE SURE 9" (I.D.) DUCT WILL PASS THROUGH TRUSS OPENING BEFORE <br />INSTALLATION OF DUCTS AND NOTIFY ENGINEER TO CHANGE IT TO 8" TO ADD MORE DIFFUSERS. <br />13. E G T BE CA IN M FIT. MO T OM OF LE 10'- <br />A.F.F. PROJECT TYPE: NEW <br />14. CTs WILL BE FURNISHED BY THE EMS CONTRACTOR FOR INSTALLATION BY THE ELECTRICAL GLOBAL NEXT GEN 30 <br />CONTRACTOR. FINAL CONNECTIONS TO THE EMS SYSTEM SHALL BE COMPLETED BY THE <br />EMS CONTRACTOR. <br />HVAC BIDDING AND EQUIPMENT NOTES <br />FOR QUOTATION ON THIS EQUIPMENT, REFER TO APPROVED VENDOR LIST ON SHEET G2.1: <br />EQUIPMENT PACKAGE: <br />RTU-1 AND RTU-2 WITH ACCESSORIES AND CURBS: <br />GENERAL CONTRACTOR TO CONTACT APPROVED VENDOR ON SHEET G2.1 FOR PRICING <br />INFORMATION. IF DESIGN CONDITIONS DIFFER FROM THOSE LISTED, CONTACT SUPPLIER <br />FOR APPROPRIATE EQUIPMENT. <br />HOODS, FANS AND FAN CURBS PACKAGE: <br />GENERAL CONTRACTOR TO CONTACT APPROVED VENDOR ON SHEET G2.1 FOR PRICING <br />INFORMATION. CURBS SHALL BE INSULATED AND TO COMPLY WITH NFPA 96 <br />REQUIREMENTS FOR HEIGHT. CURBS PROVIDED FOR EF-1 AND EF-2 MUST BE HINGED. <br />AIR DISTRIBUTION PACKAGE: <br />PACKAGE TO INCLUDE SCHEDULED AIR DEVICES AND ACCESSORIES. EQUIPMENT AND <br />MATERIAL PACKAGES ARE IN STOCK AND SHOULD BE ORDERED IMMEDIATELY UPON <br />RECEIPT OF HVAC CONTRACT TO AVOID CONSTRUCTION DELAY. CONTACT HJC CONSOLIDATOR <br />FOR DIFFUSER PACKAGE. <br />O <br />P� <br />V ) <br />J Q <br />O( <br />U)Q <br />ryZ <br />''m <br />VJ <br />o <br />Z <br />cal Cn <br />REV. DATE DESCRIPTION <br />1 02-27-25 REVISIONS <br />2 04-09-25 REVISIONS <br />ISSUE DATE: 09-27-24 <br />PROJECTNUMBER:- 240902 <br />DRAWN BY: <br />CHECKED BY: <br />SEAL <br />LSS/� <br />Al AA <br />W25955 <br />� 6- <br />\9tF n N <br />SHEET NAME <br />HVAC PLAN <br />SHEET NUMBER <br />M2.0 <br />