Laserfiche WebLink
1 2 3 <br />H <br />J <br />N3 <br />N1 <br />N4 <br />N5N6 <br />N2 <br />NA NAANBNCNDNENF <br />DOCK ADDITION <br />131 <br />TEMPORARY <br />TENT <br />133 <br />12"x10" <br />TERMINATE THRU WALL 6" AND <br />CAP FOR FUTURE EXTENSION <br />SG-1 300 <br />VD <br />SG-1 300 <br />VD <br />SG-1 300 <br />VD <br />12"x8"12"x6" <br />EXTEND RETURN DUCT <br />FULL SIZE TO 6" <br />BELOW ROOF AND <br />COVER OPEN END <br />WITH 3/4"x3/4" GALV. <br />SCREEN MESH <br />RTU-1 <br />T-STAT <br />14"x14" <br />UP THRU ROOF TO <br />RTU-1 <br />RTU-1 TO BE BALANCED FOR FULL SYSTEM FLOW OF 400 <br />CFM PER GRILLE. SYSTEM WILL BE REBALANCED TO 300 CFM <br />PER GRILLE AFTER PHASE 2 <br />EXISTING <br />COOLER <br />102 <br />EXISTING <br />ELECTRICAL <br />ROOM <br />101 <br />1 2 3 4 <br />H <br />J <br />N3 <br />N1 <br />N4 <br />N5N6 <br />N2 <br />NA NAANBNCNDNENF <br />RTU-1 <br />DRAWN BY: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />CHECKED BY: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />SHEET ISSUE DATE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />SHEET NUMBER <br />THE INFORMATION CONTAINED ON THIS AND ANY <br />RELATED DOCUMENT SHALL NOT BE USED FOR <br />ANY PURPOSE OTHER THAN THE CONVEYANCE <br />OF INFORMATION FOR THE STATED CLIENT AND <br />PROJECT WITHOUT THE EXPRESS WRITTEN <br />CONSENT OF THE ENGINEER. <br />ANY INFORMATION TRANSFERRED OR UTILIZED <br />IN AUTOCAD .DWG FORMAT SHALL BE USED FOR <br />REFERENCE ONLY <br />WEBBER/SMITH Associates, Inc. <br />20 Wright Avenue <br />Lititz, Pennsylvania 17543 <br />Phone: 717.625.4140 <br />Email:info@webbersmith.com <br />SHEET TITLE: <br />FOR <br />DRAWING STATUS <br />FINAL <br />PROJECT NUMBER <br />www.webbersmith.com <br />SEAL <br />M-100-1 <br />BWI <br />JSD <br />04/02/2024 <br />FLOOR PLAN - <br />MECHANICAL <br />2350 Pullman WSS OCTA Aspire <br />Bakeries <br />2350 Pullman Street <br />Santa Ana, CA 92705 <br />CA <br />5387 <br />© 2024 WEBBER/SMITH Associates, Inc., All Rights Reserved <br />2350 <br />Pullman,LLC <br />1/8" = 1'-0"M-100-1 <br />1 FLOOR PLAN - HVAC <br />1/8" = 1'-0"M-100-1 <br />2 OVERALL ROOF PLAN - MECHANICAL <br />NO. DATE DESCRIPTION <br />A 04/02/2024 ISSUED FOR PERMIT AND <br />CONSTRUCTION <br />1 2 <br />EXISTING FACILITY <br />KEY PLAN REFERENCE <br />NORTH <br />TRUE <br />NORTH <br />REGISTERED PROFESSIONAL ENGINEER33478 <br />JAMES S DEPEW <br />STATE OF CALIFORNIAMECHANICAL <br />4/2/24