Laserfiche WebLink
PREFABRICATED <br />INSULATED ROOF <br />CURB <br />PROVIDE WELL LINER OR <br />DUCT CONNECTION <br />WHERE REQUIRED. <br />FASTEN TO METAL CURB <br />AND STRUCTURAL <br />FRAMING <br />GALVANIZED SUPPORT <br />ANGLE - SEE <br />STRUCTURAL DRAWINGS METAL DECK <br />ROOF MEMBRANE <br />URETHANE BASED <br />SEALANT <br />BATTEN STRIP SCREWED TO <br />CURB PER ROOFING <br />MANUFACTURER REQUIREMENTS <br />MEMBRANE FLASHING <br />22 GA. GALVANIZED <br />TERMINATION STRIP SCREWED <br />TO CURB PER ROOFING <br />MANUFACTURER <br />REQUIREMENTS <br />COUNTERFLASHING <br />URETHANE BASED <br />SEALANT <br />TREATED WOOD <br />BLOCKING <br />1' <br />- <br />3 <br />" <br /> <br />M <br />I <br />N <br />. <br />EQUIPMENT BASE <br />URETHANE BASED SEALANT <br />SHALL BE CONTINUOUS ON <br />TOP OF CURB <br />RESTRAINT CLIP AND EQUIPMENT <br />BASE SCREWED TO CURB PER <br />EQUIPMENT MANUFACTURER <br />REQUIREMENTS <br />GALVANIZED <br />RESTRAINT CLIP <br />DISCHARGE TO ROOF <br />CLEANOUT PLUG (HAND TIGHTENED ONLY) <br />DIA.(AS SIZED ON PLANS) <br />COPPER PIPE - CVPC ALLOWED <br />WHEN SUPPORTED TO <br />WITHSTAND LOAD OF 250 LB. <br />DRAIN CONNECTION FULL SIZE OF <br />UNIT CONNECTION <br />DRAIN PAN <br />SEAL <br />WATER <br />TIGHT <br />ST <br />A <br />T <br />I <br />C <br /> <br />P <br />R <br />E <br />S <br />S <br />U <br />R <br />E <br /> <br />( <br />I <br />N <br />. <br />) <br />MI <br />N <br /> <br />L <br />E <br />G <br /> <br />= <br /> <br />X <br />/ <br />2 <br /> <br />+ <br /> <br />1 <br />" <br />X <br />= <br /> <br />F <br />A <br />N <br /> <br />T <br />O <br />T <br />A <br />L <br />OR INDIRECT WASTE <br />RECEPTOR <br />INSULATE PER <br />SPECIFICATIONS <br />DRAWN BY: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />CHECKED BY: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />SHEET ISSUE DATE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />SHEET NUMBER <br />THE INFORMATION CONTAINED ON THIS AND ANY <br />RELATED DOCUMENT SHALL NOT BE USED FOR <br />ANY PURPOSE OTHER THAN THE CONVEYANCE <br />OF INFORMATION FOR THE STATED CLIENT AND <br />PROJECT WITHOUT THE EXPRESS WRITTEN <br />CONSENT OF THE ENGINEER. <br />ANY INFORMATION TRANSFERRED OR UTILIZED <br />IN AUTOCAD .DWG FORMAT SHALL BE USED FOR <br />REFERENCE ONLY <br />WEBBER/SMITH Associates, Inc. <br />20 Wright Avenue <br />Lititz, Pennsylvania 17543 <br />Phone: 717.625.4140 <br />Email:info@webbersmith.com <br />SHEET TITLE: <br />FOR <br />DRAWING STATUS <br />FINAL <br />PROJECT NUMBER <br />www.webbersmith.com <br />SEAL <br />M-601-1 <br />BWI <br />JSD <br />04/02/2024 <br />MECHANICAL <br />DETAILS AND <br />SCHEDULES <br />2350 Pullman WSS OCTA Aspire <br />Bakeries <br />2350 Pullman Street <br />Santa Ana, CA 92705 <br />CA <br />5387 <br />© 2024 WEBBER/SMITH Associates, Inc., All Rights Reserved <br />2350 <br />Pullman,LLC <br />237413 - Packaged Rooftop Heat Pump Unit Schedule <br />Mark Service <br />Supply Fan Cooling Coil Heating <br />Operating <br />Weight <br />(lbs.) <br />Electrical Data <br />Disconnect <br />Requirement <br />Electrical Data Basis of Design <br />Notes <br />Air Flow (CFM) <br />HP <br />E.S.P. <br />(in.wg.) <br />Entering (°F)Leaving (°F)Capacity (MBH)Ambient Dry <br />Bulb Temp <br />(°F) <br />Output <br />(MBH) <br />Entering <br />Air Temp <br />(°F) <br />Leaving <br />Air Temp <br />(°F)M.C.A.Voltage Phase <br />Frequency <br />(Hz)Smoke Detector Manufacturer ModelDesign Supply Air Flow Min. Outside Air Flow Dry Bulb <br />Wet <br />Bulb <br />Dry <br />Bulb Wet Bulb Sensible Total <br />RTU-1 Dock 1,200 320 1.50 1.00 76.5 61.9 50.6 50.5 31.4 35.4 85 29.4 60.8 83.4 1000 10.0 480 3 60 By Electrical No Trane WHC036H4R0B**H1B1A1 Provide Economizer <br />233713 - Supply Grille Schedule <br />Mark Description Material / Finish <br />Inlet Size (In.)Front Blade <br />Spacing <br />Rear Blade <br />Spacing Border Type <br />Basis of Design Basis of Design <br />CommentsWidthHeightManufacturerModel <br />SG-1 Adjustable Supply Grille with Double Deflection Steel - Titus - 26 White 10"10"1"1"Surface Mount Titus 300RS <br />NO SCALEM-601-1 <br />A TYPICAL ROOF CURB <br />NO SCALEM-601-1 <br />B <br />CONDENSATE TRAP DETAIL <br />(PACKAGED ROOFTOP UNITS ONLY) <br />NO.DATE DESCRIPTION <br />A 04/02/2024 ISSUED FOR PERMIT AND <br />CONSTRUCTION <br />B 11/05/2024 BULLETIN #3 - PHASE 1 <br />B <br />06- <br />REGISTERED PROFESSIONAL ENGINEER33478 <br />JAMES S DEPEW <br />STATE OF CALIFORNIAMECHANICAL <br />11/5/24