Laserfiche WebLink
TAG DESCRIPTION <br />1 ARRAY TO JUNCTION BOX <br />2 JUNCTION BOX TO INVERTER <br />3 NVERTER TO SUB PANEL <br />4 SUB PANEL TO AC DISCONNECT <br />5 AC DISCONNECT TO MSP <br />6 EQUIPMENT GROUND <br />7 EQUIPMENT GROUND <br />ARRAY 1 ARRAY 2 <br />[iS <br />€g- <br />- <br />- <br />J-BOX ' <br />NEMA 3R | <br />L <br />L <br />L <br />L <br />€3 <br />LBOX <br />EMA 3 R |Ni <br />WIRE/CONDUIT SCHEDULE <br />NUMBER OF <br />CONDUCTOR TYPE/SIZE CONDUIT SIZErrYPE NOTES <br />CONDUCTORS <br />#10 AWG PV WIRE 4 NA FREE AIR <br />#10 AWG THWN-2 4 * EMT <br />#6 AWG THWN-2 3 1" EMT <br />#6 AWG THWN-2 3 1" EMT <br />#6 AWG THWN-2 3 i" EMT <br />#8 AWG SOLID COPPER 1 N/A <br />#8 AWG THWN-2 1 1" EMT <br />GENERAL ELECTRICAL NOTES: <br />1. EQUIPMENT USED SHALL BE NEW, UNLESS OTHERWISE NOTED. <br />8 MODULES 2. EQUIPMENT SHALL BE INSTALLED PROVIDING ADEQUATE PHYSICAL <br />f WORKING SPACE AROUND THE EQUIPMENT AND SHALL COMPLY WITH <br />NEC. <br />3. COPPER CONDUCTORS SHALL BE USED AND SHALL HAVE INSULATION <br />RATING 600V, 90°C, UNLESS OTHERWISE NOTED. <br />4. CONDUCTORS SHALL BE SIZED IN ACCORDANCE TO NEC. <br />CONDUCTORS AMPACITY SHALL BE DE-RATED FOR TEMPERATURE <br />INCREASE, CONDUIT FILL AND VOLTAGE DROP. <br />5. ALL CONDUCTORS, EXCEPT USE-2, SHALL BE INSTALLED IN APPROVED <br />CONDUITS OR RACEWAY. CONDUITS SHALL BE ADEQUATELY <br />SUPPORTED AS PER NEC. <br />6. RACKING AND MODULES ARE GROUNDED VIA A CONTINUOUS #10 AWG <br />COPPER CONDUCTOR, GROUNDING CLOPS, GROUNDING LUGS AND/OR <br />BONDING JUMPERS. <br />7. LOAD SIDE INTER-CONNECTION SHALL COMPLY WITH NEC <br />8. SMOKE ALARM AND CARBON MONOXIDE DETECTORS SHALL BE <br />LOCATED AS REQD PER SEC. R314 & R315 OF THE CALIFORNIA <br />RESIDENTIAL CODE (CRC) <br />9. ALL EQUIPMENT SHALL BE LISTED FOR THE APPLICATION, UL 1703 FOR <br />MODULES, UL 1741 FOR INVERTERS <br />OCINTERFACE POWER ONE PVI-6000-OUTD-US <br />INTEGRATED DC 6000W, 96% CEC <br />DISCONNECT 240VAC, 28A ACINTERFACE <br />DC+ <br />Il- <br />L <br />ARRAY 1 DETAILS <br />NO. OF MODULE PER STRING 8+7 <br />NO. OF STRINGS 2 <br />ARRAY WATTS AT STC 4.905kW <br />MAX. VOLTAGE 482.7V <br />ARRAY 2 DETAILS <br />NO. OF MODULE PER STRING 8 <br />NO. OF STRINGS 2 <br />ARRAY WATTS AT STC 5.232kW <br />MAX. VOLTAGE 482.7V <br />SOLAR LOAD CENTER <br />100A 240VAC <br />g -PT 7 <br />MPPT 112]000 O <br />3 <br />MODULE SPECIFICATION <br />MODEL NO.SPR-327NE-WHT-D <br />PEAK POWER 327W <br />RATED VOLTAGE (Vmp)54.7V <br />RATED CURRENT (Imp)5.98A <br />OPEN CIRCUIT VOLTAGE (Voc)641.9V <br />SHORT CIRCUIT CURRENT (Isc)6.46A <br />INVERTER SPEC FICATION <br />INVERTER MAKE POWER ONE <br />INVERTER MODEL PVI-6000-OUTD-US <br />MAX. DC VOLT RATING 600V <br />MAX. AC APPARENT POWER 6000W <br />NOMINAL AC VOLTAGE 240V <br />MAX AC CURRENT 28A <br />INVERTER SPEC FICATION <br />INVERTER MAKE POWER ONE <br />INVERTER MODEL PVI-5000-OUTD-US <br />MAX. DC VOLT RATING 600V <br />MAX. AC APPARENT POWER 5000W <br />NOMINAL AC VOLTAGE 240V <br />MAX AC CURRENT 23A <br />NEW <br />COMBINATION <br />MAIN SERVICE PANEL <br />225A, 240VAC, 1 PH <br />NOTE: A CENTER-FED <br />BUS WILL NOT BE USED <br />- 200A <br />1.1 NOTE: UNDERGROUND <br />UTILITY <br />40A <br />./. <br />09 <br />C] <br />L2 0 <br />Nll <br />r <br />DCINTERFACE POWER ONE PVI-5000-OUTD-US <br />INTEGRATED DC 5000W, 96% CEC <br />DISCONNECT 240VAC, 23A ACINTERFACE <br />/ <br />V <br />30A 4 <br />MPPT 1 <br />MPPT <br />MPFT 1 <br />Ll •m <br />AC DISCONNECT 15A <br />240VAC, 100A .-I <br />NEMA 3R, UL LISTED / SMSDATA <br />70A FUSES LOGGER- 4 ®V V I =2-352 -INTERACTIVE CIRCUIT <br />| BREAKER WlLLBEPLACEDAT <br />*- EXTREME END OF BUSS <br />1 OA *. /OPPOSITE UTILITY SUPPLY <br />L2 Ll N <br />L <br />NEW GROUNDING ROD <br /> WITH #4 AWG BONDING <br />ARMORED GROUNDING (8.AG.) <br />ANDB" COPPER ROD <br />NOTE: WHEN METALLIC CONDUIT IS USED <br />IT MUST BE BONDED AT BOTH ENDS. <br />7 <br />-3 <br />- TITLE: <br />dNON Ll 1.2 SINGLE LINEUTILITY <br />Bl-DIRECTIONAL DIAGRAM <br />ELECTRIC METER <br />_LNEWGROUNDING CONDUCTOR WATH#4 <br />- AWG BAG. ANDt COPPER ROD <br />(NEW 225 AMP SERVICE REQUIRES 4 AWG CONDUCTOR TO A <br />10FT. RUN OF UNDERGROUND METAL WATER PIPE. BOND ON JOB NO: 20587A <br />THE OUTSIDE OF STRUCTURE AT THE POINT OF ENTRANCE, OR <br />WITHIN THE FIRST 5 FEET AS IT ENTERS THE BUILDING. IF AN DATE: 02/25/13 <br />UNDERGROUND METAL WATER PIPE FEEDS A 2ND BUILDING, IT <br />MUST ALSO BE USED.) <br />REV: 01 <br />PV 3