Laserfiche WebLink
,--SANTA <br />NAJIiII <br />Planning & Building Agency <br />Building Safety Division <br />20 Civis Center Plaza <br />P,O. Box 1988 (M-19) <br />Santa Ana, CA 92702 <br />(7r 4) 647-5800 <br />www.santa-ana.org <br />sol-01 cac 2013 <br />Project Address:1026 S. DENNIS ST, SANTA ANA, CA 92704 <br />Contractor Gompany Name:SOUTHWEST SUN SOLAR, INC <br />contractorLicenseNumber: 1004667 <br />YES NO Are the following applicable to the proposed project? <br />Will the PV system layout provide the required three-foot wide clear access pathways <br />per Section 605.11 of the California Fire Code, and is this shown on the roof plan? <br />Will the PV system be installed on a roof having only one roofrng layer with no <br />overlays? <br />Will the PV anay be flush mounied to the exisling roof so that the plane of the <br />modules (panels) are parallel to the plane of the roof? <br />Will the PV system weigh maximum 4 pounds per square feet or less? <br />Will the PV system be installed where the modules do not overhang any roof edges <br />(such as eaves, gabled ends, ridges and hips)? <br />Will the PV system be installed with a space of 2" minimum to 10" maximum between <br />the underside of modules and the surface of the roof? <br />Will the PV system be installed without using any ballast system or counter-weight <br />system? <br />Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet <br />and is this maximum horizontal spacing shown on the plans? <br />Will the minimum 5/16" lag screws be installed with a minimum of 2-112 inch <br />embedment inlo roof rafters (with pre-drilled holes) and is this minimum embedment <br />shown on the plans? <br />Are ALL the structural pages of the plans WET stamped and signed by a Califomia <br />licensed professional engineer? (including project specific site plan, PV layout, <br />EI tr <br />2 Ettr <br />Ettr <br />Ettr <br />Etr <br />Etr <br />Etr <br />4 <br />5 <br />6 <br />7 <br />I Eltr <br />9 Etr <br />10 Etr <br />anchorage spacing, anchorage details and manufacture/s PV suppo information.) <br />I cerlify under penalty of perjury under the laws of the State of Galifornia above is true: <br />p1i61 x6ms. TRANG CONG PHAlvl <br />Phone Number: 714 582 3909 <br />Signature: <br />Dale: <br />Reu,811712015 <br />PERIV IT@SOUTHWESTSUNSOLAR.COIV <br />tg <br />RESIDENTIAL <br />PHOTOVOLTAIC <br />CHEGKLIST <br />Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMTLY RESTDENCES Onty <br />lnstructions: The licensed contractor of record shall complete all sections, answer the ten questions and <br />sign the certification seclion below. A copy of this form shall be attached to each of TWO sets of plans, of <br />minimum 11"x'17"size. lf answerino NO toanvof the questions. Dlan check shall be reouired. <br />Email Address: