My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2350 S Pullman St - DEF - Exterior & Interior Framing - Plan
PBA
>
Building
>
ProjectDox
>
P
>
Pullman St
>
2350 S Pullman St
>
2350 S Pullman St - DEF - Exterior & Interior Framing - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/6/2025 5:00:12 AM
Creation date
9/6/2025 5:00:04 AM
Metadata
Fields
Template:
Plan
Permit Number
101124188
Full Address
2350 S Pullman St
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
210
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ESR-3064P I Most Widely Accepted and Trusted <br />CITY OF SANTA ANA <br />PlannirA an� yuilding Agency <br />ge o 6 <br />Interior Nonload-Bearing Wall Heights — Composite <br />Tables - Composite Pages 19-20 <br />Additional notes applicable to pages 19 and 20: <br />• Gypsum wallboard must be a minimum of 5/8 inch <br />(15.9 mm) thick and Type X, complying with ASTM <br />C1396 and manufactured by American Gypsum, <br />CertainTeed, Georgia Pacific, Lafarge, National Gypsum, <br />Temple-Inland, or USG. <br />• Fasteners for attaching the gypsum wallboard to the <br />studs and tracks must be No. 6, Type S, fine thread <br />drywall bugle head screws conforming to ASTM C1002. <br />Installation of the gypsum wallboard must be in <br />accordance with GA-216 or ASTM C840. <br />• Each gypsum wallboard panel must be attached to the <br />top and bottom track with a minimum of 3 fasteners <br />spaced a maximum of 16 inches (406 mm) on center. <br />Interior Wall Limiting Heights — Non -Composite — Fully <br />Braced Span Tables Pages 21-22 <br />Interior Wall Limiting Heights — Braced at 48" o.c. Span <br />Tables Pages 23-24 <br />Curtain Wall Limiting Heights — Single Span Pages 25-27 <br />Curtain Wall Limiting Heights -Double Span Pages 28-30 <br />Note: Exterior curtain walls must be designed for a <br />transverse load of no less than 10 psf (478 Pa). <br />Combined Axial and Lateral Loads Pages 31-41 <br />Floor Joist Spans Pages 42-55 <br />Header Loads Pages 56-57 <br />Web Crippling Load Tables Pages 58-60 <br />Note: Values for which the bearing length to web height <br />ratio (N/h) exceeds 1 orbearing length to thickness ratio <br />(N/t) exceeds 210 are outside the scope of this report. <br />Ceiling/Soffit Spans (S-Sections) Pages 61-67 <br />Section Properties & Ceiling Spans (F-Sections) Page 68 <br />Section Properties & Ceiling Spans (U-Sections) Page 69 <br />All other items and pages in the "Product Technical Guide" <br />are outside the scope of this report. <br />3.2 Material: <br />The SSMA metal framing members are cold -formed from <br />steel coils conforming to ASTM Al003 Structural Grade 50 <br />Type H (ST50H); ASTM Al003 Structural Grade 33 Type H <br />(ST33H); ASTM A653 SS Grade 33; ASTM A653 SS Grade <br />50 Class 1; or ASTM Al003 Nonstructural Grade 33 (NS33). <br />The steel conforming to ASTM A653 must have a <br />minimum metallic coating designation of G60 or A60 in <br />accordance with ASTM A653 for applications other than <br />interior nonload-bearing walls. The steel conforming to <br />ASTM A653 may have a minimum metallic coating <br />designation of G40 or A40 in accordance with ASTM A653 <br />for interior nonload-bearing wall applications. <br />The steel conforming to ASTM A1003 ST50H or ST33H <br />must have a minimum metallic coating designation of G60, <br />A60, AZ50, GF30, T1-25, or T2-100 in accordance with <br />ASTM Al003. <br />The steel conforming to ASTM A1003 NS33 must have a <br />minimum metallic coating designation of G40, A40, AZ50, <br />GF30, T1-25, or T2-100 in accordance with ASTM Al003. <br />4.0 DESIGN AND INSTALLATION if <br />4.1 Design: RR ApApproved <br />4.1.1 IBC Method: The section p opUr'h�5`fbAh 111 -ISSUANCE <br />formed steel framing members rec gnized in this report <br />have been determined in accordance with the applicable <br />edition of the North American Spe if ti ��pp��ogesign of <br />Cold -Formed Steel Structural Mem157 51'00). The <br />moments listed in this report are alto ab OW6ments and are <br />used with Allowable Strength Desi n (ASD) for flexural <br />members with the compression fla ige fullyr <br />other conditions of compression flange bracing, the <br />allowable moment must be determined in accordance with <br />the applicable edition of AISI S100. The design of flexural <br />members must address combined bending and web <br />crippling, and combined bending and shear, as applicable in <br />accordance with the applicable edition of AISI S100. <br />4.1.2 IRC Method: The S-sections listed in Table 1 of this <br />report qualify for use with prescriptive requirements of <br />the IRC. T-sections with flange width of 1.250 inches <br />(31.75 mm) or greater qualify for use with the prescriptive <br />requirements of the IRC. For use of all other sections under <br />the IRC, the cold -formed steel framing members must be <br />limited to engineered structures, in accordance with IRC <br />Section R301.1.3. <br />When the framing members are used to construct <br />buildings that do not conform to the applicable requirements <br />of IRC Sections R505.1, R603.1 or R804.1.1, and for <br />framing members not identified in Table 1 of this report, the <br />structural analysis and design must be in accordance with <br />the IBC, as described in Section 4.1.1 of this report. <br />4.2 Installation: <br />The framing members must be installed in accordance with <br />the applicable code, the approved plans and this report. If <br />there is a conflict between the plans submitted for approval <br />and this report, this report governs. The approved plans <br />must be available at the jobsite at all times during <br />installation. <br />5.0 CONDITIONS OF USE <br />The SSMA metal framing members described in this report <br />comply with, or are suitable alternatives to what is specified <br />in, those codes listed in Section 1.0 of this report, subject to <br />the following conditions: <br />5.1 The cold -formed steel members must be installed in <br />accordance with the applicable code, the approved <br />plans and this report. <br />5.2 Minimum uncoated base -metal thickness of the cold - <br />formed steel members as delivered to the jobsite must <br />be at least 95 percent of the design base -metal <br />thickness. <br />5.3 Complete plans and calculations verifying compliance <br />with this report must be submitted to the code official <br />for each project at the time of permit application. The <br />calculations and drawings must be prepared and <br />sealed by a registered design professional where <br />required by the statutes of the jurisdiction in which the <br />project is to be constructed. <br />5.4 Framing members cold -formed from NS33 steel are <br />limited to use in interior nonload-bearing walls subject <br />to a maximum 10 psf (478 Pa) transverse load. <br />Framing members without the steel classification <br />designated must be considered NS33 steel (see <br />Section 7.0). <br />5.5 Framing members with a height -to -thickness (h/t) ratio <br />of more than 200 must be provided with web stiffeners <br />in accordance with Sections B1.2 and C3.2.2 of AISI <br />
The URL can be used to link to this page
Your browser does not support the video tag.