My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
26 Civic Center Plz - REV 5 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Civic Center Plz
>
26 Civic Center Plz
>
26 Civic Center Plz - REV 5 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2025 4:36:18 AM
Creation date
9/12/2025 5:00:04 AM
Metadata
Fields
Template:
Plan
Permit Number
20181364
20184057
30146548
40138556
40139543
101117272
101117273
101117274
101117275
101117276
101117286
101120941
101121751
Full Address
26 Civic Center Plz
Street Number
26
Street Name
Civic Center
Street Suffix
Plz
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
92
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
NOTE: <br />1. AT DOORS,THRESHOLD ACTS AS TRANSITION BETWEEN <br />DIFFERING MATERIALS <br />CARPET, TYPE "1"CARPET, TYPE "2" <br />RES. TILE/ RUBBER CORK <br />CARPET TO RES. TILE/ RUBBER CORK C <br />TRANSITION STRIPCARPET <br />CARPET TO PORCELAIN TILE <br />B1 <br />MARBLE THRESHOLD <br />THIN SET-PORCELAIN TILE <br />CARPET <br />CARPET TO CARPET D <br />SEALED CONCRETE/ EPOXY TO RES. TILE/ RUBBER CORKB2 <br />MARBLE THRESHOLD <br />RES. TILE/ RUBBER CORKEPOXY/ CONCRETE <br />MAX 1:2 <br />(RISE: <br />RUN) <br />IF ADJACENT CARPETS ARE FROM A DIFFERENT MANUFACTURER AND <br />TRANSITION DOES NOT OCCUR AT DOORS, PROVIDE RESILIENT TRANSITION <br />STRIP <br />1/ <br />2 <br />" <br /> <br />M <br />A <br />X <br />. <br />3/ <br />8 <br />" <br />MAX 1:2 (RISE: RUN) <br />LEVELING COMPOUND <br />1 2 <br />CONC. <br />CARPET TO CONCRETE A <br />ALUM. THRESHOLD <br />CARPET <br />MA <br />X <br />1/ <br />2 <br />" <br />MAX SLOPE 1/2 (RISE) <br />1/ <br />4 <br />" <br />#139 <br />RFI <br />CO <br />V <br />E <br /> <br />B <br />A <br />S <br />E <br />B A <br />D <br /> PORCELAIN WALL TILE OVER <br />THINSET BASE <br />COVE BASE TILE W/ 3/8" <br />RADIUS TO MATCH <br />FLOOR TILES <br />THIN-SET PORCELAIN <br />FLOOR TILE <br />PORCELAIN TILE COVE BASE <br />CARPET AT BASE RES. TILE/ RUBBER CORK AT BASE <br />COVE RUBBER <br />BASERES. TILE/ RUBBER CORK <br />STRAIGHT RUBBER <br />BASE <br />CARPET <br />FLOOR <br />C SEALED CONCRETE AT BASE <br />SLIM FOOT <br />BASE <br />SEALED CONCRETESEALANT JOINT <br />LIQUID APPLIED <br />EPOXY COVE BASE <br />E EPOXY BASE <br />CO <br />V <br />E <br /> <br />B <br />A <br />S <br />E <br />4" <br />EPOXY FLOORING <br />4" <br />VERTICAL CHANGE IN <br />LEVEL WITHOUT EDGE <br />TREATMENT <br />BEVELED CHANGE IN LEVEL <br />MAX <br />1:2 (RISE:RUN) <br />1/ <br />4 <br />" <br />1/ <br />2 <br />" <br />1/ <br />4 <br />" <br />1/ <br />4 <br />" <br />1 2 <br />TROUGH <br />6 1/2" <br />B ANTI-TIP RAIL <br />CONCRETE BACK <br />FILL SEE S-SERIES <br />DRAWINGS <br />EXISTING <br />CONCRETE SLAB <br />NON-SHRINK GROUT <br />1/4" DIA. x 2" EMB. SLEEVE <br />ANCHORS <br />1 <br />1 <br />/ <br />2 <br />" <br /> <br />M <br />I <br />N <br />. <br />TH <br />I <br />C <br />K <br />N <br />E <br />S <br />S <br /> <br />O <br />F <br /> <br />F <br />L <br />O <br />O <br />R <br /> <br />C <br />O <br />N <br />V <br />E <br />R <br />I <br />N <br />G <br />VA <br />R <br />I <br />E <br />S <br />. <br /> <br />B <br />A <br />S <br />E <br />D <br /> <br />O <br />N <br />NOTE: ALL TROUGH SIDES, BOTTOMS & SURFACE AT EDGE OF <br />TROUGH MUST BE TRUE TO 1/4" OVER 20'-0 SPAN (NON- <br />CUMULATIVE). <br />1. <br />2. <br />3. <br />CONCRETE BACK FILL (TROUGHS) NOTES: <br />FINISHED SLAB MUST MAINTAIN NO MORE THAN 1/4" OVER <br />20'-1" OUT OF LEVER IN ALL DIRECTIONS. <br />FINISHED SLAB MUST BE NO HIGHER THAN TOP OF <br />FINSHED RAIL MINUS THE THICKNESS OF THE FLOOR <br />OVERING AT ANY POINT. <br />COCRETE BACKFILL & THE CLEANING OF RAILS TO BE <br />DONE BY OTHERS. <br />(E) CONC. SLAB <br />CARPET TILE <br />3/8" STONE <br />TILE OVER <br />THINSBT <br />CONC.LEVELING <br />COMPOUND <br />SCHIENE 3/8" <br />ALIGN <br />MIN. <br />2"MAX. <br />1" <br />RUBBER INTREGRAL <br />TREAD & NOSING; <br />PROVID 2" MIN. <br />WARNING STRIP AT TOP <br />& BOTTOM TREADS <br />RUBBER INTREGRAL <br />TREAD & NOSING; SEE <br />FINISH PLAN <br />ST <br />09-30-2025 <br />O <br />ARCHITECT <br />FOFCALE <br />REN. <br />AT ARN <br />NO. <br />SE <br />LICNE <br />C-27893 <br />D <br />T <br />EC <br />HIT <br />ARC <br />DAVID SCHNEE <br />I <br />U <br />E <br />I <br />H <br />U <br />9 <br />AS.O <br />A <br />F R A N CN <br />4 0 8 0 <br />H <br />I <br />N <br />S <br />L11 <br />AL <br />E <br />CR <br />N D E N VA <br />,N I N G <br />CRAE <br />TCEIT <br />S C <br />S <br />N <br />N <br />G R O U P <br />7 <br />S <br />5 06 <br />C <br />0718 <br />2 <br />P <br />R <br />A <br />O <br />90 <br />A <br />EU <br />C <br />+ <br />ER <br />4 <br />SHEET TITLE AND NO. <br />ISSUE DATE <br />PROJECT: <br />CA REG. <br />Project Arch.---- <br />---- <br />PERMIT SET 1ST ISSUANCE <br />BID SET <br />FINAL PERMIT/CONFORM SET <br />09/29/2023 <br />04/30/2024 <br />08/02/2024 <br />22575-01 <br />26 CIVIC CENTER <br />PLAZA <br />SANTA ANA <br />CA 92701 <br />SANTA ANA <br />LIBRARY <br />RENOVATION <br />CITY OF SANTA ANA <br />26 CIVIC CENTER PLAZA <br />SANTA ANA, CA 92701 <br />REV # DESCRIPTION DATE <br />1 BACKCHECK REV-1 03.01.2024 <br />2 CITY REVIEW REV-1 08.02.2024 <br />3 CITY REVIEW REV-2 10.18.2024 <br />4 CITY REVIEW REV-3 01.27.2025 <br />5 CITY REVIEW REV-4 04.07.2025 <br />6 CITY REVIEW REV-5 06.27.2025 <br /> <br />REVIEWED FOR CONSTRUCTABILITY: <br /> 80470 <br />SEAN THOMAS. P.E. RCE NO: <br />PRINCIPAL CIVIL ENGINEER <br />DATE: <br />RECOMMENDED FOR CONSTRUCTION: <br /> 62968 <br />JASON GABRIEL. P.E. RCE NO: <br />PRINCIPAL CIVIL ENGINEER <br />DATE: <br />A9.2-1 <br />INTERIOR DETAILS <br />- FLOOR AND BASE <br /> 3" = 1'-0"01 IFL - FLOORING TRANSITIONS <br /> 3" = 1'-0"09 IFL - WALL BASE DETAILS <br /> 6" = 1'-0"11 IFL - TYPICAL CHANGE IN LEVEL <br /> 6" = 1'-0"2 IFL - MOBILE COMPACT SHELVING RECESSED RAIL DETAILS <br /> 3" = 1'-0"12 IFL - FLOORING STONE TILE TRANSITION <br />#020 <br />ASI <br />15 IFL - PATCHING HOLES ON CATWALK PLAN <br />CONDITOIN A: PANEL LEFT IS WIDER THAN 3" <br />CONDITOIN B: PANEL LEFT IS LESS THAN 3" <br />14 IFL - PATCHING WEB PLATE SECTOIN <br />#107 <br />RFI <br /> 3" = 1'-0"10 IFL - RUBBER STAIR TREAD @ STAIR #1, #2 & #3 <br />#016.1 <br />ASI
The URL can be used to link to this page
Your browser does not support the video tag.