1. ALL FIXTURES SHALL HAVE APPROPRIATE U.L. LABEL, DAMP, OR WET AS <br />REQUIRED BY LOCAL CODES. <br />2. ALL FIXTURES SHALL INCLUDE ALL ACCESSORIES FOR INSTALLATION <br />ACCORDING TO ALL CALIFORNIA ELECTRICAL CODES. <br />3. PRIOR TO ORDERING ANY LIGHTING EQUIPMENT, THE CONTRACTOR SHALL <br />VERIFY ALL LOCATIONS AND RECESS DEPTHS. <br />4. ALL LAMPS SHALL BE INSTALLED ACCORDING TO THE ATTACHED FIXTURE <br />SCHEDULE. <br />5. CONTRACTOR SHALL VERIFY FINAL VOLTAGES AND CEILING TRIM <br />COMPATIBILITY PRIOR TO ORDERING FIXTURES. <br />6. CEILING THICKNESS IN EXCESS OF 3/4" SHALL BE IDENTIFIED IN WRITING BY <br />CONTRACT. <br />7. PROVIDE APPROVED FIRE-RATED ENCLOSURES FOR ALL LIGHTING <br />FIXTURES LOCATED IN A FIRE-RATED CEILING. <br />8. WALLS DIRECTLY ILLUMINATED SHALL BE INSTALLED AND FINISHED IN A <br />MANNER TO ELIMINATE SHADOWS OR BLEMISHES (I.E. HANG DRY WALL <br />VERTICALLY). <br />9. ANY FIXTURE SUBSTITUTIONS MUST BE APPROVED BY THE ARCHITECT AND <br />OWNER'S REPRESENTATIVE PRIOR TO BID. CONTRACTOR MUST BE <br />PREPARED TO SUPPLY A SAMPLE AND/OR PHOTOMETRIC DATA IF <br />REQUESTED. <br />10. OUTDOOR LIGHTING FIXTURES THAT ARE USED TO ILLUMINATE A <br />PREMISES, ARCHITECTURAL FEATURE OR LANDSCAPE FEATURE ON <br />PRIVATE PROPERTY SHALL BE DIRECTED, SHIELDED, OR LOCATED IN SUCH A <br />MANNER THAT THE LIGHT SOURCE IS NOT VISIBLE OFFSITE, TO MINIMIZE <br />LIGHT EMISSION ABOVE THE HORIZONTAL PLANE AND SO THAT LIGHT DOES <br />NOT FALL ONTO SURROUNDING PROPERTIES OR CREATE GLARE HAZARDS <br />WITHIN PUBLIC RIGHTS-OF-WAY. <br />11. ALL EMERGENCY BATTERY PACKS SHALL BE FURNISHED WITH 90-MIN <br />MINIMUM BACK UP CAPABILITY AND PROVIDE NO LESS THAN 1/3 OF THE FULL <br />LUMEN OUTPUT OF ANY INDIVIDUAL LAMP. LED LIT, TEST SWITCHES TO BE <br />INTEGRAL TO FIXTURE, NOT REMOTE MOUNTED. CONTRACTOR SHALL <br />ENSURE THAT A MINIMUM OF 1-FOOTCANDLE IS PROVIDED AT FLOOR LEVEL <br />ALONG PATH OF EGRESS. <br />12. LIGHTING INSTALLED IN CORRIDORS AND STAIRWELLS SHALL BE <br />CONTROLLED BY OCCUPANT SENSING CONTROLS THAT SEPARATELY <br />REDUCE THE LIGHTING POWER BY AT LEAST 50% WHEN THE SPACE IS <br />UNOCCUPIED. <br />13. LIGHTING CONTROL DEVICES AND SYSTEMS, BALLASTS AND LUMINARIES <br />SHALL COMPLY TO 2022 CENC, SECTION 110.9. <br />14. SHADED FIXTURE INDICATES EGRESS FIXTURE WITH 90 MIN. BATTERY <br />BACKUP OR CONNECTED TO BUILDING LIGHTING INVERTER. <br />15. EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. (CBC <br />1013.3) <br />16. ELECTRICALLY POWERED EXIT SIGNS SHALL BE LISTED AND LABELED IN <br />ACCORDANCE WITH UL 924. (CBC SECTION 1013.5 <br />17. THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR A <br />DURATION OF NOT LESS THAN 90 MINUTES AND SHALL CONSIST OF <br />STORAGE BATTERIES, UNIT EQUIPMENT OR AN ON-SITE GENERATOR. THE <br />INSTALLATION OF THE EMERGENCY POWER SYSTEM SHALL BE IN <br />ACCORDANCE WITH SECTION 2702. <br />I <br />U <br />E <br />I <br />H <br />U <br />9 <br />AS.O <br />A <br />FRANCN <br />4 0 8 0 <br />H <br />I <br />N <br />S <br />L11 <br />AL <br />E <br />CR <br />NDEN VA <br />,N I N G <br />CRAE <br />TCEI T <br />SC <br />S <br />N <br />N <br />G R O U P <br />7 <br />S <br />5 06 <br />C <br />07 18 <br />2 <br />P <br />R <br />A <br />O <br />90 <br />A <br />EU <br />C <br />+ <br />ER <br />4 <br />SHEET TITLE AND NO. <br />ISSUE DATE <br />PROJECT: <br />CA REG. <br />Project Arch.---- <br />---- <br />22575-01 <br />26 CIVIC CENTER <br />PLAZA <br />SANTA ANA <br />CA 92701 <br />SANTA ANA <br />LIBRARY <br />RENOVATION <br />CITY OF SANTA ANA <br />26 CIVIC CENTER PLAZA <br />SANTA ANA, CA 92701 <br />ELECTRICAL-PLMUMBING-MECHANICAL <br />1920 MAIN STREET, SUITE 820 <br />IRVINE, CA92614 <br />TEL: 949.516.6480 <br />BID SET <br />FINAL PERMIT/CONFORM <br />SET <br />04/30/2024 <br />08/02/2024 <br />E0.2-1 <br />LIGHTING FIXTURE <br />SCHEDULES <br />GENERAL NOTES <br />REV # DESCRIPTION DATE <br />#184 RFI 05.19.2025 <br />#005 ASI 11.27.2024 <br />#184 <br />RFI