Laserfiche WebLink
R <br />FE <br />C <br />FE <br />C <br />FE <br />C <br />FE <br />C <br />FE <br />C <br />DW <br />FE <br />C <br />P P P P P P <br />MCP <br />FT FT FT FT FT FT <br />J J J J J <br />J <br />J <br />J <br />J <br />1 <br />1 <br />2 <br />2 <br />3 <br />3 <br />4 <br />4 <br />5 <br />5 <br />6 <br />6 <br />7 <br />7 <br />8 <br />8 <br />9 <br />9 <br />10 <br />10 <br />CC <br />DD <br />EE <br />FF <br />HH <br />+42" <br />STAFF <br />OFFICE <br />001 <br />MECH <br />003 <br />FIRE <br />AL.RM <br />006 <br />ELEVATOR-ABAN. <br />007 <br />OFFICE <br />012 <br />OFFICE <br />013 <br />STAFF <br />MEETING <br />ROOM <br />014 OFFICE <br />015 <br />ELEV. <br />CONTROL <br />018 <br />OFFICE <br />017 <br />(E) ELEV. <br />CONTROL <br />RM. <br />005A <br />+42" <br />LBA-9,11,13&15 LBA-17,19,21&23 <br />LBA-2,4,6&8 <br />LBA-10,12,14&16 LBA-18,20,22&24 <br />ALL <br />GENDER <br />RESTROOM <br />010 <br />STAFF <br />BREAK <br />ROOM <br />004 <br />MECH-ABAN. <br />008 <br />+42" <br />1 <br />4 <br />ELECTRICAL <br />019 <br />33 <br />7 <br />7 <br />13 <br />13 <br />9 <br />27 <br />27 <br />27 <br />25 <br />25 <br />1 <br />E4.0-2 <br />STAFF <br />OFFICE <br />001 <br />LBA-1,3,5&7 <br />ARCHIVES <br />002 <br />OFFICE <br />016 <br />1 1 1 <br />1 1 <br />LBM <br />2 <br />STORAGE <br />005 <br />2 <br />E4.0-1 <br />DB-2 <br />MS-A <br />TR -T1 <br />LBL <br />LBB <br />LBA <br />004LBB- 7 <br />10 6 <br />(E) ELECTRICAL <br />VAULT <br />LBB- 12 <br />5 <br />7 7 7 <br />7 7 <br />LP <br />8 <br />8 <br />8 <br />8 <br />8 <br />8 <br />8 <br />8 <br />2 <br />9 <br />(E) ELEVATOR <br />HYDRAULIC <br />PUMP <br />7 <br />13 <br />FIRE <br />AL.RM <br />006 <br />LBA- 10 <br />10 <br />10 <br />10 <br />(E) FA <br />LBA- 4 <br />9 <br />LBA- 710 <br />LBA-31 <br />LBA-25,27&29 <br />2 <br />2 <br />INV-1 <br />LBA- 2 <br />LBB-9&11&13 <br />LBB-21&23 <br />LBB-17&19 <br />23 25 <br />+42"+42" <br />1012 <br />LBB-8&10&12 <br />LBB-14&16 <br />16 14 <br />DW <br />+18" <br />4 <br />6 <br />LBB-2&4&6 <br />2 <br />12 <br />20 <br />20 <br />18 <br />18 <br />LBB-18&20 <br />LBB-24 <br />LBB-26 <br />LBB-1&3&5 <br />13 <br />5 555 <br />3 <br />3 <br />1111 <br />44 <br />46 <br />44 <br />44 <br />15 <br />JANITOR. <br />023 <br />LBA-42 16 <br />17 <br />17 <br />LBB-21 <br />11 <br />LBB-27 <br />17 <br />19 <br />STORAGE <br />022 <br />ALL <br />GENDER <br />RESTROOM <br />011 <br />9 <br />+42" <br />11 <br />11 <br />11 <br />8 RF. <br />+42" <br />+42" <br />+18" <br />+18" <br />#009 <br />ASI <br />#009 <br />ASI <br />#009 <br />ASI <br />#009 <br />ASI <br />#009 <br />ASI #009 <br />ASI <br />2 <br />25 <br />34 <br />31 <br />32 <br />LBA-32,34&36 <br />29 <br />36 <br />LBB-29 <br />2 <br />18 <br />LBB-18 <br />LBA-35 <br />LBA-39 <br />29 <br />27 <br />#009 <br />ASI <br />#009 <br />ASI <br />#009 <br />ASI <br />35 <br />35 <br />35 <br />35 <br />I <br />U <br />E <br />I <br />H <br />U <br />9 <br />AS.O <br />A <br />FRANCN <br />4 0 8 0 <br />H <br />I <br />N <br />S <br />L11 <br />AL <br />E <br />CR <br />NDEN VA <br />,N I N G <br />CRAE <br />TCEI T <br />SC <br />S <br />N <br />N <br />G R O U P <br />7 <br />S <br />5 06 <br />C <br />07 18 <br />2 <br />P <br />R <br />A <br />O <br />90 <br />A <br />EU <br />C <br />+ <br />ER <br />4 <br />SHEET TITLE AND NO.N <br />ISSUE DATE <br />PROJECT: <br />CA REG. <br />Project Arch.---- <br />---- <br />22575-01 <br />26 CIVIC CENTER <br />PLAZA <br />SANTA ANA <br />CA 92701 <br />SANTA ANA <br />LIBRARY <br />RENOVATION <br />CITY OF SANTA ANA <br />26 CIVIC CENTER PLAZA <br />SANTA ANA, CA 92701 <br />ELECTRICAL-PLMUMBING-MECHANICAL <br />1920 MAIN STREET, SUITE 820 <br />IRVINE, CA92614 <br />TEL: 949.516.6480 <br />BID SET <br />FINAL PERMIT/CONFORM <br />SET <br />04/30/2024 <br />08/02/2024 <br />E2.4-1 <br />ELECTRICAL <br />REMODEL <br />BASEMENT POWER <br />PLAN <br />1/8" = 1'-0"1 ELECTRICAL NEW POWER PLAN BASEMENT <br />1. ALL RECEPTACLES ON COMMON WALLS SHALL BE SEPARATE BOXES <br />AND OFFSET MINIMUM 24 INCHES. <br />2. ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE <br />PROTECTED FROM SPREAD OF FIRE WITH AN APPROVED FIRESTOP <br />SYSTEM EQUAL OR GREATER THAN THE FIRE RATING OF THE WALL. <br />3. ALL DEVICE HEIGHTS SHALL BE VERIFIED WITH THE ARCHITECT PRIOR <br />TO ROUGH-IN. <br />4. EXPOSED CABLE/CONDUCTORS INSTALLED IN A PLENUM SPACE SHALL <br />CONFORM TO CEC, ARTICLE 300.22(C). <br />5. PROVIDE ADDITIONAL J-BOX NEAR PANEL FOR MULTIPLE HOMERUN <br />CIRCUITRY <br />6. POWER AND DATA CORE AND FACEPLATES TO MATCH COLOR OF <br />ADJACENT WALL. <br />7. COORDINATE RECEPTACLE LOCATIONS WITH DATA OUTLET LOCATIONS <br />AND GANG DEVICES IN BOXES AND COVER PLATES. <br />8. WHEN EXPOSED CEILINGS OR OPEN GRID CONDITIONS OCCUR, THE <br />CONTRACTOR SHALL PROVIDE THE FOLLOWING: <br /> 7.1 ALL BRANCH CIRCUITS SHALL BE IN EMT CONDUITS. <br /> 7.2 ALL BRANCH CIRCUITS SHALL BE ROUTED, NEATLY AND IN <br />PARALLEL TO STRUCTURES OR DUCT WORK. <br /> 7.3 VISUALLY OBJECTIONABLE BRANCH CIRCUITS SHALL BE <br />REROUTED AT THE REQUEST OF THE ARCHITECT AT NO <br />ADDITIONAL COST. <br />9. PROVIDE DEDICATED NEUTRAL FOR EACH NEW CIRCUIT, EXCEPT <br />WHERE OTHERWISE NOTED. HOME RUN CONDUCTORS MAY BE <br />COMBINED INTO ONE CONDUIT. NO RACEWAY OR CABLE SHALL <br />CONTAIN MORE THAN NINE (9) CURRENT CARRYING <br />CONDUCTORS.WHERE MULTIPLE CONDUCTORS IN EXCESS OF THREE <br />(3) ARE INDICATED ON THESE DRAWINGS, THEY HAVE BEEN DERATED <br />AS REQUIRED BY CEC ARTICLE 310 REQUIREMENTS. <br />10. NO EQUIPMENT, J-BOXES, ETC. REQUIRING ACCESS SHALL BE LOCATED <br />IN HARD LID CEILING AREAS (UNLESS ACCESS PANEL IS PROVIDED. <br />COORDINATE WITH ARCHITECT.) RELOCATE ANY EXISTING EQUIPMENT, <br />J-BOXES, ETC. TO ACCESSIBLE CEILING AREA. <br />11. UNLESS SPECIFICALLY SHOWN AS (E), (R), (ER), (D), EXISTING OR NON- <br />BOLD, ALL ELECTRICAL DEVICES SHOWN ARE NEW. <br />12. CONTRACTOR TO PROVIDE 1/2"CONDUIT WITH PULLSTRING TO ALL NEW <br />THERMOSTAT LOCATIONS. COORDINATE SCOPE OF WORK WITH <br />MECHANICAL DRAWINGS. <br />13. FLOOR PENETRATIONS SHALL BE FIELD LOCATED TO MISS <br />STRUCTURAL FLOOR FRAMING/REINFORCING BELOW, OTHERWISE, <br />SITE SPECIFIC DETAILS SHALL BE SUBMITTED TO THE CITY FOR <br />APPROVAL PRIOR TO INSTALLATION. CONTRACTOR SHALL SCAN ALL <br />LOCATIONS PRIOR TO CORING. <br />14. CONTRACTOR SHALL PROVIDE PERMANENT MACHINE TYPE LABELS ON <br />ALL ELECTRICAL EQUIPMENT, RECEPTACLES AND SWITCHES. <br />15. ALL RECEPTACLES AND SWITCHES SHALL BE PROVIDED WITH DECORA <br />PLATES. <br />16. CONTRACTOR TO PROVIDE PERMANENT TYPED LABELS ON ALL <br />EXISTING VAV BOXES DISCONNECT SWITCHES. CONTRACTOR TO <br />REFER TO MECHANICAL DRAWING FOR NUMBER OF VAV BOXES AND <br />LOCATIONS. <br />17. ALL LOW VOLTAGE DEVICES ARE SHOWN FOR REFERENCE ONLY. <br />18. ALL RECEPTACLES SHALL BE PROVIDED AS TAMPER RESISTANT <br />RECEPTACLES. <br />3 SAW-CUT EXISTING SLAB TO ALLOW FOR INSTALLATION OF NEW <br />CONDUIT. WIRE SIZE PER HOMERUN AND ADDITIONAL NOTES. <br />2 REFER TO TELECOM/AUDIOVISUAL DRAWINGS FOR FLOOR BOX MAKE <br />AND MODEL. FLOOR BOX PROVIDED BY TELECOM OR AUDIOVISUAL <br />CONTRACTOR, COORDINATE IN THE FIELD. CONTRACTOR TO PROVIDE <br />RECEPTACLE CONFIGURATION AND CIRCUITING AS SHOWN ON THE <br />DRAWINGS. <br />1 CONTRACTOR TO PROVIDE WALL FURNITURE BOX. INSTALL FLEX <br />CONDUIT AS NEED TO CONNECT TO FURNITURE SYSTEM. PROVIDE 3/4''C., <br />4#10 + 2#10(N), 1#10 EQUIPMENT GROUND FOR ALL FURNITURE FEED <br />CONNECTIONS. TIE EQUIPMENT GROUND AND ISOLATED GROUND <br />CONNECTIONS INTO SINGLE POINT ON FURNITURE FEED WHIP. PROVIDE <br />HANDLE-TIE ON CIRCUIT BREAKERS AS NEEDED. COORDINATE EXACT <br />SIZE AND LOCATION IN THE FEILD WITH THE OWNER'S REPRESENTATIVE. <br />GENERAL NOTES <br />KEY NOTES <br />4 PROVIDE GFCI RECEPTACLE IN ELEVATOR PIT. <br />5 CONTRACTOR TO REUSE EXISITNG DISCONNECT SERVING LIGHTING <br />INSIDE ELEVATOR CAB. PROVIDE NEW POWER CONNECTION TO EXISTING <br />DISCONNECT SWITCH. <br />6 CONTRACTOR TO PROVIDE NEW DISCONNECT SWITCH PER SINGLE LINE <br />DIAGRAM SHEET E0.1-2 FOR EXISTING ELEVATOR. <br />7 THE LAST CIRCUIT IN THE FURNITURE FEED SHALL BE CONTROLLED BY <br />OCCUPANY SENSOR TO COMPLY WITH THE TITLE 24 CONTROLLED <br />RECEPTACLE CODE REQUIREDMENT, §130.5(d). <br />8 PROVIDE RECEPTACLE AND CONDUIT SURFACE MOUNTED. CONTRACTOR <br />SHALL INSTALL CONDUIT IN BASEMENT (LEVEL BELOW) AND ROUTE <br />CONDUIT SURFACE MOUNTED UP TO NEW SURFACE MOUNTED <br />RECEPTACLE. <br />9 PROVIDE POWER CONNECTION TO TWO-WAY COMMUNICATION SYSTEM. <br />REFER TO SHEET TN-7.0-3 FOR ADDITIONAL INFORMATION AND <br />REQUIREMENTS. <br />10 EXISTING FIRE ALARM PANEL TO BE REUSED. CONTRACTOR SHALL <br />DESIGN-BUILD A COMPLIANT FIRE ALARM SYSTEM PER SPECIFICATIONS <br />SECTION 28 3100. <br />11 PROVIDE RECEPTACLE AND 120V POWER CONNECTION TO SERVE <br />FAUCET AND SOAP DISPENSER. PROVIDE RECEPTACLE AND 120V POWER <br />CONNECTION TO SERVE HAND DRYER MOTOR. ELECTRICAL BOXES NEED <br />TO BE VERTICALLY, FLUSH MOUNTED TO BACKING MATERIAL, TO ALLOW <br />PLUMBING AND COMPONENT CLEARANCE. COORDINATE EXACT LOCATION <br />AND REQUIREMENTS IN THE FIELD. <br />12 PROVIDE SWITCH ABOVE COUNTER AND CONNECT TO RECEPTACLE TO <br />SERVE GARBAGE DISCPOSAL. COORDINATE EXACT REQUIREMENTS AND <br />LOCATIONS IN THE FIELD. <br />13 REFER TO TELECOM/AUDIOVISUAL DRAWINGS SHEET TA9.1-2 FOR TV <br />WALL MOUNT BOX FOR MAKE AND MODEL. WALL BOX PROVIDED BY <br />TELECOM OR AUDIOVISUAL CONTRACTOR, COORDINATE IN THE FIELD. <br />CONTRACTOR TO PROVIDE RECEPTACLE CONFIGURATION AND <br />CIRCUITING AS SHOWN ON THE DRAWINGS. <br />14 PROVIDE POWER CONNECTION TO DRINKNG FOUNTAIN. COORDINATE <br />EXACT LOCATION AND REQUIREMENTS IN THE FIELD. <br />15 DEDICATED QUAD RECEPTACLE FOR POWER CONNECTION TO AV RACK. <br />COORDINATE EXACT LOCATION IN THE FIELD. <br />16 CONTRACTOR TO PROVIDE MOTOR RATED SWITCH AND POWER <br />CONNECTION TO SMOKE CURTAIN. PROVIDE FIRE ALARM CONNECTION <br />AND COORDINATE WITH FIRE ALARM DESIGN-BUILD CONTRACTOR. <br />COORDINATE EXACT REQIREMENTS AND LOCATION IN THE FIELD. <br />17 CONNECT TO UNDERCABINET LIGHTING AS SHOWN ON E3.0-1. <br />REV # DESCRIPTION DATE <br />#020 ASI 03.21.2025 <br />#008 ASI 04.11.2025 <br />#164 RFI 05.02.2025 <br />#184 RFI 05.19.2025 <br />#009 ASI 06.04.2025 <br />#009 <br />ASI