Laserfiche WebLink
FE <br />C <br />FE <br />C <br />FEC <br />2T <br />2T <br />FT <br />FT <br />J <br />J <br />D <br />D <br />J <br />J J J <br />1 <br />1 <br />2 <br />2 <br />3 <br />3 <br />4 <br />4 <br />5 <br />5 <br />6 <br />6 <br />7 <br />7 <br />8 <br />8 <br />9 <br />9 <br />10 <br />10 <br />CC <br />DD <br />EE <br />FF <br />HH <br />STUDY <br />202 <br />VESTIBULE <br />SEATING <br />200A <br />HISTORY <br />222 <br />STAFF <br />RESTROOM <br />2T3 <br />ALL <br />GENDER <br />RESTROOM <br />2T2 <br />YOUNG <br />ADULT <br />211 <br />MAKER <br />STORAGE <br />216 <br />STUDY <br />201 <br />+42" <br />+60" <br />+42" <br />+42" <br />+42" <br />YA STUDY <br />BOOTH <br />211A <br />54'' <br />5 <br />5 <br />3 <br />+42"+42" <br />STAFF <br />MEETING <br />ROOM <br />221 <br />OFFICE <br />223 <br />STAFF <br />OFFICE <br />224 <br />OFFICE <br />226 <br />OFFICE <br />225 <br />1 <br />L2M <br />L2AL2L <br />JAN.RM <br />217 <br />2 2 <br />2 <br />1 <br />1 1 <br />1 <br />3 <br />(E) SMR ON <br />RAILING <br />DOWN TO <br />BELOW <br />L2A-16,18,&206 <br />ELEC. RM. <br />218 <br />INV-2 <br />DDC <br />3 <br />VIDEO <br />EDITING <br />BOOTH <br />213 <br />STUDY <br />220 <br />ALL <br />GENDER <br />RESTROOM <br />2T1 STORAGE <br />200B <br />1 <br />1 <br />L2L-40,42 <br />5 <br />46 <br />46 <br />42 <br />2 <br />42 <br />42 <br />44 <br />42 <br />#10L2A-1&3 <br />35 <br />5 7 <br />7 <br />7 <br />L2A-5&7 3 <br />1 <br />L2A-9&11&13 <br />#10 <br />9 <br />9 <br />911 <br />11 <br />11 <br />13 <br />13 <br />13 13 <br />1 <br />#10 <br />#10 <br />#10 <br />#10 <br />L2A-15&17 <br />15 <br />15 <br />15 <br />17 <br />5 <br />L2A-33 <br />33 <br />33 <br />33 <br />33 L2A-25,27 <br />L2A-61 <br />&63 <br />L2A-35 <br />5 <br />35 <br />35 <br />35 <br />35 <br />31 <br />L2A-31 <br />33 <br />L2A-19&21 <br />31 31 31 <br />4 <br />L2A-39&41&43 <br />41 <br />39 <br />43 43 <br />37 <br />37 <br />37 <br />L2A-37 <br />10 <br />2 <br />2 <br />2 <br />L2A-2 <br />2 <br />2 <br />4 <br />4 <br />4 <br />L2A-4 <br />L2A-53 <br />7 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />L2A-32 32 32 <br />32 <br />32 <br />5 <br />6 <br />8 <br />8 <br />L2A-6&8&10 <br />3 <br />10 <br />2 <br />10 <br />10 <br />MAKER <br />SPACE <br />212 <br />18 18 <br />18 <br />18 <br />18 <br />20 <br />22 <br />22 <br />22 <br />22 <br />L2A-18&20&22 <br />VIDEO <br />RECORDING <br />BOOTH <br />214 <br />24&26 <br />24 <br />L2A-24&26 <br />L2A-28&30 <br />28&30 <br />28 <br />3D PRINTER <br />L2A-12&14&16 <br />12 <br />12 <br />14 <br />16 <br />2 <br />2 44 <br />L2A-48,50 <br />9 <br />L2A-38&40 <br />38 <br />38 <br />4038 <br />L2A-34&36 <br />8 <br />42 <br />42 <br />L2A-42&44&46 <br />11 <br />28&30 <br />24&26 <br />L2A-72 <br />12 <br />12 <br />7 <br />17 <br />17 <br />2 <br />35 <br />2 2 2 <br />L2A-55&57 <br />55 5557 <br />57 55 <br />2 2 <br />41 41 <br />28&30 <br />24&26 <br />46 <br />42 <br />2 <br />L2A-234 <br />L2A-29 <br />4 <br />4 <br />L2A-59 <br />4 <br />4 <br />I <br />U <br />E <br />I <br />H <br />U <br />9 <br />AS.O <br />A <br />FRANCN <br />4 0 8 0 <br />H <br />I <br />N <br />S <br />L11 <br />AL <br />E <br />CR <br />NDEN VA <br />,N I N G <br />CRAE <br />TCEI T <br />SC <br />S <br />N <br />N <br />G R O U P <br />7 <br />S <br />5 06 <br />C <br />07 18 <br />2 <br />P <br />R <br />A <br />O <br />90 <br />A <br />EU <br />C <br />+ <br />ER <br />4 <br />SHEET TITLE AND NO.N <br />ISSUE DATE <br />PROJECT: <br />CA REG. <br />Project Arch.---- <br />---- <br />22575-01 <br />26 CIVIC CENTER <br />PLAZA <br />SANTA ANA <br />CA 92701 <br />SANTA ANA <br />LIBRARY <br />RENOVATION <br />CITY OF SANTA ANA <br />26 CIVIC CENTER PLAZA <br />SANTA ANA, CA 92701 <br />ELECTRICAL-PLMUMBING-MECHANICAL <br />1920 MAIN STREET, SUITE 820 <br />IRVINE, CA92614 <br />TEL: 949.516.6480 <br />BID SET <br />FINAL PERMIT/CONFORM <br />SET <br />04/30/2024 <br />08/02/2024 <br />E2.4-3 <br />ELECTRICAL <br />REMODEL SECOND <br />FLOOR POWER <br />PLAN <br />1/8" = 1'-0"1 ELECTRICAL NEW POWER PLAN - SECOND FLOOR <br />1. ALL RECEPTACLES ON COMMON WALLS SHALL BE SEPARATE BOXES <br />AND OFFSET MINIMUM 24 INCHES. <br />2. ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE <br />PROTECTED FROM SPREAD OF FIRE WITH AN APPROVED FIRESTOP <br />SYSTEM EQUAL OR GREATER THAN THE FIRE RATING OF THE WALL. <br />3. ALL DEVICE HEIGHTS SHALL BE VERIFIED WITH THE ARCHITECT PRIOR <br />TO ROUGH-IN. <br />4. EXPOSED CABLE/CONDUCTORS INSTALLED IN A PLENUM SPACE SHALL <br />CONFORM TO CEC, ARTICLE 300.22(C). <br />5. PROVIDE ADDITIONAL J-BOX NEAR PANEL FOR MULTIPLE HOMERUN <br />CIRCUITRY <br />6. POWER AND DATA CORE AND FACEPLATES TO MATCH COLOR OF <br />ADJACENT WALL. <br />7. COORDINATE RECEPTACLE LOCATIONS WITH DATA OUTLET LOCATIONS <br />AND GANG DEVICES IN BOXES AND COVER PLATES. <br />8. WHEN EXPOSED CEILINGS OR OPEN GRID CONDITIONS OCCUR, THE <br />CONTRACTOR SHALL PROVIDE THE FOLLOWING: <br /> 7.1 ALL BRANCH CIRCUITS SHALL BE IN EMT CONDUITS. <br /> 7.2 ALL BRANCH CIRCUITS SHALL BE ROUTED, NEATLY AND IN <br />PARALLEL TO STRUCTURES OR DUCT WORK. <br /> 7.3 VISUALLY OBJECTIONABLE BRANCH CIRCUITS SHALL BE <br />REROUTED AT THE REQUEST OF THE ARCHITECT AT NO <br />ADDITIONAL COST. <br />9. PROVIDE DEDICATED NEUTRAL FOR EACH NEW CIRCUIT, EXCEPT <br />WHERE OTHERWISE NOTED. HOME RUN CONDUCTORS MAY BE <br />COMBINED INTO ONE CONDUIT. NO RACEWAY OR CABLE SHALL <br />CONTAIN MORE THAN NINE (9) CURRENT CARRYING <br />CONDUCTORS.WHERE MULTIPLE CONDUCTORS IN EXCESS OF THREE <br />(3) ARE INDICATED ON THESE DRAWINGS, THEY HAVE BEEN DERATED <br />AS REQUIRED BY CEC ARTICLE 310 REQUIREMENTS. <br />10. NO EQUIPMENT, J-BOXES, ETC. REQUIRING ACCESS SHALL BE LOCATED <br />IN HARD LID CEILING AREAS (UNLESS ACCESS PANEL IS PROVIDED. <br />COORDINATE WITH ARCHITECT.) RELOCATE ANY EXISTING EQUIPMENT, <br />J-BOXES, ETC. TO ACCESSIBLE CEILING AREA. <br />11. UNLESS SPECIFICALLY SHOWN AS (E), (R), (ER), (D), EXISTING OR NON- <br />BOLD, ALL ELECTRICAL DEVICES SHOWN ARE NEW. <br />12. CONTRACTOR TO PROVIDE 1/2"CONDUIT WITH PULLSTRING TO ALL NEW <br />THERMOSTAT LOCATIONS. COORDINATE SCOPE OF WORK WITH <br />MECHANICAL DRAWINGS. <br />13. FLOOR PENETRATIONS SHALL BE FIELD LOCATED TO MISS <br />STRUCTURAL FLOOR FRAMING/REINFORCING BELOW, OTHERWISE, <br />SITE SPECIFIC DETAILS SHALL BE SUBMITTED TO THE CITY FOR <br />APPROVAL PRIOR TO INSTALLATION. CONTRACTOR SHALL SCAN ALL <br />LOCATIONS PRIOR TO CORING. <br />14. CONTRACTOR SHALL PROVIDE PERMANENT MACHINE TYPE LABELS ON <br />ALL ELECTRICAL EQUIPMENT, RECEPTACLES AND SWITCHES. <br />15. ALL RECEPTACLES AND SWITCHES SHALL BE PROVIDED WITH DECORA <br />PLATES. <br />16. CONTRACTOR TO PROVIDE PERMANENT TYPED LABELS ON ALL <br />EXISTING VAV BOXES DISCONNECT SWITCHES. CONTRACTOR TO <br />REFER TO MECHANICAL DRAWING FOR NUMBER OF VAV BOXES AND <br />LOCATIONS. <br />17. ALL LOW VOLTAGE DEVICES ARE SHOWN FOR REFERENCE ONLY. <br />18. ALL RECEPTACLES SHALL BE PROVIDED AS TAMPER RESISTANT <br />RECEPTACLES. <br />4 PROVIDE RECEPTACLE AND 120V POWER CONNECTION TO SERVE <br />FAUCET AND SOAP DISPENSER. PROVIDE RECEPTACLE AND 120V POWER <br />CONNECTION TO SERVE HAND DRYER MOTOR. ELECTRICAL BOXES NEED <br />TO BE VERTICALLY, FLUSH MOUNTED TO BACKING MATERIAL, TO ALLOW <br />PLUMBING AND COMPONENT CLEARANCE. COORDINATE EXACT LOCATION <br />AND REQUIREMENTS IN THE FIELD. <br />3 PROVIDE POWER CONNECTION TO DRINKNG FOUNTAIN. COORDINATE <br />EXACT LOCATION AND REQUIREMENTS IN THE FIELD. <br />2 CONTRACTOR TO PROVIDE POKE-THRU BOX, SIMILAR TO TYPE "FP4" <br />SPECIFIED AND PROVIDED BY TELECOM/AUDIOVISUAL CONTRACTOR, SEE <br />SHEET TN9.0-7. CONTRACTOR TO PROVIDE RECEPTACLE <br />CONFIGURATION AND CIRCUITING AS SHOWN ON THE DRAWINGS. <br />1 REFER TO TELECOM DRAWINGS FOR 2 HOUR FIRE RATED POKE-THRU <br />BOX MODEL. CONTRACTOR TO PROVIDE RECEPTACLE CONFIGURATION <br />AS SHOWN ON THE DRAWINGS. <br />GENERAL NOTES <br />KEY NOTES <br />5 REFER TO TELECOM/AUDIOVISUAL DRAWINGS SHEET TA9.1-2 FOR TV <br />WALL MOUNT BOX FOR MAKE AND MODEL. WALL BOX PROVIDED BY <br />TELECOM OR AUDIOVISUAL CONTRACTOR, COORDINATE IN THE FIELD. <br />CONTRACTOR TO PROVIDE RECEPTACLE CONFIGURATION AND <br />CIRCUITING AS SHOWN ON THE DRAWINGS. <br />6 CONTRACTOR TO INTERCEPT EXISTING CIRCUITS SERVING EXISTING TO <br />REMAIN SURFACE MOUNTED RACEWAY LOCATED ON RAILING. <br />CONTRACTOR SHALL PROVIDE THREE (3) CIRCUITS TO EXISTING <br />RACEWAY AND RECIRCUIT AND LABEL RECEPTACLES AS NEEDED, FOR A <br />COMPLETE INSTALLATION FOR EXISTING TO REMAIN <br />RACEWAY/RECEPTACLE. <br />7 CONTRACTOR TO INTERCEPT EXISTING CIRCUITS SERVING EXISTING TO <br />REMAIN RECEPTACLES LOCATED IN MEZZANINE LEVEL ABOVE. <br />COORDINATE SCOPE OF WORK IN THE FIELD. <br />8 CONTRACTOR TO PROVIDE MOTOR RATED SWITCH AND POWER <br />CONNECTION TO PROJECTION SCREEN MOTOR. COORDINATE EXACT <br />REQIREMENTS AND LOCATION IN THE FIELD. <br />9 CONTRACTOR TO PROVIDE CEILING MOUNTED RECEPTACLE FOR <br />PROJECTOR. COORDINATE EXACT REQIREMENTS AND LOCATION IN THE <br />FIELD. <br />10 CONTRACTOR TO PROVIDE MOTOR RATED SWITCH AND POWER <br />CONNECTION TO SMOKE CURTAIN. PROVIDE FIRE ALARM CONNECTION <br />AND COORDINATE WITH FIRE ALARM DESIGN-BUILD CONTRACTOR. <br />COORDINATE EXACT REQIREMENTS AND LOCATION IN THE FIELD. <br />11 CONNECT INVERTER TO PANELBOARD AND CIRCUIT NUMBER AS SHOWN <br />AND INDICATED USING 1"C, 2#4, 1#10GND. <br />12 CONNECT TO UNDERCABINET LIGHTING AS SHOWN ON E3.0-3. <br />#008 <br />ASI <br />#020 <br />ASI <br />REV # DESCRIPTION DATE <br />#020 ASI 03.21.2025 <br />#008 ASI 04.11.2025