My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10180863_2230 W. COTTER - Plan
PBA
>
Building
>
Plans
>
C
>
Cotter St
>
2230 N Cotter St
>
10180863_2230 W. COTTER - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/5/2021 8:55:16 AM
Creation date
10/25/2020 5:21:12 PM
Metadata
Fields
Template:
Plan
Permit Number
10180863
Full Address
2230 N Cotter St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
NOTES: <br />1) ALL BOLTS SHALL BE TORQUED TO <br />30 LBS. PER FOOT <br />2) SYSTEM INSTALLATION TO ADHERE <br />TO ALL MANUFACTURER'S <br />RECOMMENDATIONS. (SPEC. SHEETS <br />ATTACHED), NATIONAL AND LOCAL <br />BUILDING CODES <br />3) PANELS TO BE MOUNTED IN <br />ACCORDANCE WITH UNI-RAC/ <br />UNI-STRUT INSTRUCTIONS AND <br />LOCAL CODE <br />4) CUTS TO UNI-STRUT ARE TO BE <br />PAINTED WITH COLD GALV. PAINT <br />5) ANTI-SEIZE THREAD COMPOUND <br />SHALL BE APPLIED TO ALL SS BOLT <br />HARDWARE TO PREVENT GALLING <br />6) KEEP BOLT IN STANCHION UNTIL <br />RAILS ARE FASTENED TO PREVENT <br />WATER ENTRY <br />NOTES (CONTINUED): <br />12) DO NOT COVER (MECHANICAL AND PLUMBING) VENTS <br />THROUGH THE ROOF WITH THE COLLECTOR <br />13) WHEN INSTALLED OVER A ROOF COVERING OF WOOD eSHAKES OR SHINGLES WITH LESS THAN A CLASS B OR C <br />RATING, AN ALUMINUM OR CORROSION-RESISTANT IRON tSUBSTRATE OF 26 GAUGE MINIMUM THICKNESS <br />EXTENDING AT LEAST 6IN. BEYOND THE OUTER EDGES OF <br />THE COLLECTOR GROUP IS REQUIRED <br />L-BRACKET <br />PV QUICK MOUNT DETAILS <br />-RACKING COMPONENTS <br />NOT INCLUDED <br />SPl <br />3/,i / e .. 3/ „ <br />>1"-20 T-BOLT <br />MID CLAMP 1 <br />- SOLAR MODULE <br />- MID CLAMP <br />UNIRAC <br />SOLARMOUNT RAIL <br />- <br />0- - <br />14/t <br />y <br />GREEN SOURCE SOLUTION,- 74"-20 SERRATED LLC <br />FLANGE NUT <br />22325 MYANDOTTE ST <br />SOLAR MODULE CANOGA PARK, CA 91303 <br />«ISSUE DATE 0-80 <br />2/22/2014 <br />REV.:DATE:-DESCRIPTION:-BY CALI <br />Dpi Or <br />, cha <br />;ion f <br />s SHK <br />iolatioi <br />N. <br />-Lid. 3 862304 <br />UNIRAC <br />SOLARMOUNT RAIL <br />-ARMOUNT 34"-20 T-BOLT 1 <br />.ICE KIT >7-20 SERRATED 7 <br />FLANGE NUT - <br />78-IVA 74 <br />HEX BOLT <br />%"-16 FLANGE NUT r <br />UNIR*GL <br />SOLARMOUNT RAIL <br />2*4 Rafter 1 <br />24"O.C. <br />1-- <br />0 0- <br />13 <br />7) INSTALLATION SHALL COMPLY - +WITH ARTICLE 690 OF THE 2010 CEC <br />AND CBC <br />9%9 <br />4-0-0--- <br />Unirac <br />Solarmount Rails -0- * 0-,- - <br />8) IN ANY LOCATION THAT THE <br />CONDUIT RUNS THROUGH THE ROOF <br />AND INTO THE BUILDING, THAT <br />CONDUIT IS TO BE KEPT 18" BELOW <br />THE ROOF SURFACE AND IDENTIFIED <br />AS A SOLAR CIRCUIT <br />6###64 --- <br />PV Quick Mount 7 <br />Spaced Every 4' --- --- <br />--- <br />9) PROVIDE GROUND FAULT <br />ITEM <br />NO. <br />"-8" <br />PROJECT INFORMATION <br />Re- <br />10 SUNPOWER <br />E20-327 <br />SOLAR MODULES <br />& <br />1 PVI-3.0-OUTD-S-US-A <br />INVERTER <br />ROOF MOUNT <br />/ <br />DESCRIPTION QTY COMP. SHINGLE <br />PROTECTION PER 690.5 CEC <br />10) KEEP BOLT IN STANCHION UNTIL <br />RAILS ARE FASTENED TO PREVENT <br />WATER ENTRY <br />11) ARRAYS WILL BE PLACED 3"-8" <br />ABOVE ROOF SURFACE <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />FLASHING, 12"X 12"X .050",5052, MILL 1 <br />QBLOCK, CLASSIC,-A360.1 CAST AL, MILL 1 <br />tHANGER BOLT, 5/16'Lx 6" 18-8_SS 1 <br />WASHER, SEALING, 5/16" ID X 3/4" OD, 1 <br />EPDM BONDED SS <br />NUT, HEX, 5/16-18, UNC-2,18-8 SS 2 <br />WASHER, FLAT, 19/64" ID x 7/8" OD x 1/8" 1EPDM <br />WASHER, FENDER, 5/16" ID X 1" OD, 18-8 SS 1 <br />WASHER, SPLIT-LOCK, 5/16" ID, 18-8 SS 1 <br />l <br />Lul- <br />DRAV'.N BY: -- CHK.:- APV.:- <br />- GSS <br />CLIENT INFORMATION <br />ANGEL <br />TORO <br />2230 COTTER ST <br />SANTA ANA, CA <br />92706 <br />PHOTOVOLTAIC <br />SOLAR SYSTEM <br />SHEET TITLE <br />-5 der%-\4- <br />CONNECTION <br />DETAILS <br />10'-6" <br />SHEET NUMBER
The URL can be used to link to this page
Your browser does not support the video tag.