My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10180994_W ST ANNE - Plan
PBA
>
Building
>
Plans
>
S
>
St Anne Pl
>
2309 W St Anne Pl
>
10180994_W ST ANNE - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/2/2021 11:54:11 PM
Creation date
10/25/2020 5:22:03 PM
Metadata
Fields
Template:
Plan
Permit Number
10180994
Full Address
2309 W St Anne Pl
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PV ARRAY COMBINER/JUNCTION BOX <br />PROVIDES TRANSITION FROM ARRAY WIRING <br />TO CONDUIT WIRING <br />GROUND FAULT PROTECTION PROVIDED IN <br />INVERTER <br />THE INVERTER ARE AT 240 VOLTS FROM <br />-13°F TO+113°D <br />INVERTER IS LISTED TO UL-1998, UL-1741 / <br />IEEE-929, IEEE-1547 FCC PART 15 CLASS A AND <br />B <br />INVERTER OUTPUT DISCONNECT RATED AT <br />30-AMPS, 2P, 240 VAC, NEMA 3R <br />1) RESIDENTIAL BUILDINGS - THE <br />MARKINGS MAY BE PLACED WITHIN THE <br />MAIN SERVICE DISCONNECT. THE <br />MARKINGS SHALL BE PLACED ON THE <br />OUTSIDE COVER IF THE MAIN SERVICE <br />DISCONNECT IS OPERABLE WITH THE <br />SERVICE PANEL CLOSED <br />2) COMMERCIAL BUILDINGS - THE <br />MARKING SHALL BE PLACED ADJACENT <br />TO THE MAIN SERVICE DISCONNECT <br />CLARITY VISIBLE FROM THE LOCATION <br />WHERE THE LEVER IS OPERATED <br />3) MARKINGS: VERBIAGE FORMAT, AND <br />TYPE OF MATERIAL <br />C. MATERIAL: <br />(1) REFLECTIVEM WEATHER <br />RESISTANTMATERIAL <br />SUITABLE FOR <br />ENVIRONMENT (USE UL 969 <br />AS STANDARD FOR <br />WEATHER RATING) <br />DURABLE ADHESIVE <br />MATERIALS MEET THIS <br />REQUIREMENT <br />4) MARKING REQUIREMENTS ON DC <br />CONDUIT RACEWAYS, ENCLOSURES, <br />CABLE ASSEMBLIES, DC COMBINERS, <br />AND JUNCTION BOXES: <br />PV SYSTEM WARNING <br />ELECTRIC SHOCK <br />IF A GROUND FAULT IS INDICATED, NORMALLY <br />GROUNDED CONDUCTOR MAY BE <br />UNGROUNDED AND ENERGIZED <br />MOUNTED ON THE INVERTER <br />NEC 600.35 SIGNAGE <br />PV SYSTEM WARNING <br />ELECTRIC SHOCK <br />THIS EQUIPMENT SUPPLIED <br />FROM MORETHEN ONE SOURCE <br />TERMINAL MAYBE ENERGIZED <br />IN OPEN POSITION <br />MOUNTED ON THE INVERTER <br />PHOTOVOLTAIC SYSTEM <br />AC DISCONNECT <br />OUTPUT CURRENT <br />OUTPUT VOLTAGE <br />MOUNTED ON THE INVERTER <br />LEVI BUILDERS <br />ISSUE DATE <br />3/17/2014 <br />X <br />EQUIPMENT GROUNDING CONDUCTORS ON <br />AC AND DC SIDE SIZED ACCORDING TO THE CEC <br />250.122 <br />FLOATING ARRAY ONLY-GROUND <br />REFERENCING NOT ALLOWED <br />(IE. UNDERGROUNDED SYSTEM) <br />ALL TWIST ON WIRE CONNECTORS AND <br />PRESSURE LUGS LISTED FOR THE <br />ENVIRONMENT <br />ALL USER ACCESSIBLE FUSES TO BE <br />TOUCH SAFE, HOLDERS NO LIVE CONTACT <br />A. VERBIAGE: <br />CAUTION: <br />SOLAR ELECTRIC SYSTEM <br />CONNECTED <br />B. FORMAT: <br />(1) WHITE LETTERING ON RED <br />BACKGROUND <br />(2) MINIMUM 3/8 INCHES <br />LETTER HEIGHT <br />(2) ALL LETTERS SHALL BE <br />CAPITALIZED <br />A. MARKINGS: PLACEMENT, <br />VERBIAGE, FORMAT, AND <br />TYPE OF MATERIAL <br />B. PLACEMENT: <br />MARKINGS SHALL BE <br />PLACED EVERY 10 FEET ON <br />ALL INTERIOR AND EXTERIOR <br />DC CONDUITS, RACEWAYS, <br />ENCLOSURES, AND CABLE <br />ASSEMBLIES, AT TURNS, <br />ABOVE AND/OR BELOW <br />PENETRATIONS, ALL DC <br />COMBINERS, AND JINCTION <br />BOXES <br />WARNING <br />2 SOURCES OF POWER PV/AC <br />DISCONNECT @ ADJACENT LOCATION <br />MOUNTED ON THE MAIN PANEL <br />WARNING <br />DUAL POWER SUPPLY <br />PHOTOVOLTAIC <br />SYSTEM <br />MOUNTED ON MAIN PANEL <br />PHOTOVOLTAIC SYSTEM <br />AC DISCONNECT <br />RATED MPP CURRENT --A <br />RATED MPP VOLTAGE -V <br />RATEDISC --A <br />RATED VOC -V <br />MOUNTED ON DC DISCONNECT <br />REV.:DATE:-DESCRIPTION:-BY <br />PROJECT INFORMATION <br />BONDING FITTINGS TO BE USED WITH <br />METAL CONDUIT WHEN DC SYSTEM VOLTAGE <br />IS MORE THEN 250VDC <br />(4) ARIAL OR SIMILAR FONT, <br />NOT BOLD <br />C. VERBIAGE: <br />CAUTION: SOLAR CIRCUIT <br />CAUTION: SOLAR CIRCUIT PHOTOVOLTAIC SYSTEM INVERTER <br />10 SUNPOWER <br />E20-327 <br />SOLAR MODULES <br />& <br />GROUNDED CONDUCTORS TO BE WHITE <br />AND EQUIPMENT GROUNDING CONDUCTORS <br />TO BE GREEN, GREENA'ELLOW OR BARE PER <br />200.6 (A) 2010 CEC <br />ALL BREAKERS FOR PV SUITABLE FOR <br />BACKFEED SHALL NOT NEED LINE AND LOAD <br />NOTE: <br />• THE CONNECTORS SHALL BE OF THE LATCHING OR LOCKING TYPE AS <br />SHOWN BELOW FOR BOTH ALTERNATING CURRENT AS WELL AS <br />DIRECT CURRENT: <br />600 VDC MAX MOUNTED ON THE INVERTER 1 PVI-3.0-OUT[)-S-US-A <br />INVERTER36" IN SIZE <br />MOUNTED ON CONDUIT BOTH AC AND DC <br />AND ALSO ON THE MOUNTED ON DC DISCONNECT <br />J-BOXES/COMBINER·BOXES ROOF MOUNT <br />EVERY 10' ON CONDUIT <br />COMP. SHINGLE <br />CONDUCTOR TYPE RATED FOR 90°C WET <br />RATED AND SUNLIGHT RESISTANT <br />ALL NON-CURRENT METAL PARTS, <br />FRAMES, BOXES ARE PROPERLY BONDED AND <br />GROUNDED TO THE GROUNDING SYSTEM <br />WARNING <br />ELECTRIC SHOCK HAZARD <br />Powrve DC wite Negotive DC wire THE DC CONDUCTORS OF THIS <br />cont•o<tod:o DC connoctod to DC-PHOTOVOLTAIC SYSTEM ARE <br />UNGROUNDED AND MAY BE <br />ENERGIZED <br />NEC 690.35 (F) <br />WARNING <br />INVERTER OUTPUT CONNECTION DRAWN BY: - CHK.: - APV.:- <br />DO NOT RELOCATE THIS OVERCURRENT DEVICE <br />MOUNTED ON THE INVERTER GSS <br />MOUNTED BY BREAKER <br />IN MAIN PANEL <br />ALL WIRING UNDER MODULES TO BE <br />SECURED PROPERLY WITH NO LOOSE <br />CONDUCTORS-FREE FROM ROOF MATERIAL <br />CONTACT AND INSTALLED IN A WORKMAN LIKE <br />MANNER <br />1. I IE 19-*7*U od=61%Ft_-LUL KVP t: <br />F,guro 56: DC Connochon Fc,minoti CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED <br />CLIENT INFORMATION <br />MARISELA <br />REYES <br />ALL CONDUIT TO BE PROPERLY SECURED <br />AND SUPPORTED PER CH.3 2010 CEC 2309 W ST ANNE PL <br />SANTA ANA, CA <br />92704 <br />1. CAUTION: SOLAR ELECTRIC CONNECTED - SIGNAGE <br />LOCATION: RESIDENTIAL BUILDINGS THE MARKING MAY BE <br />PLACED WITHIN THE MAIN SERVICE DISCONNECT. THE <br />MARKING SHALL BE PLACED ON THE OUTSIDE COVER IF <br />THE MAIN SERVICE DISCONNECT IS OPERABLE WITH THE <br />SERVICE PANEL CLOSED. <br />PHOTOVOLTAIC <br />SOLAR SYSTEM <br />SHEET TITLE <br />2. CAUTION: SOLAR CIRCUIT-LOCATION: SHALL BE PLACED <br />EVERY 10' ON ALL INTERIOR AND EXTERIOR DC CIRCUITS, <br />RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES, AT <br />TURNS, ABOVE AND BELOW PENETRATIONS, ALL DC <br />COMBINER AND JUNCTION BOXES <br />PV <br />SIGNAGE <br />A. WHITE LETTERING ON A RED BACKGROUND <br />B. MINIMUM %" LETTER HEIGHT <br />C. ALL LETTER SHALL BE CAPITALIZED <br />D. ARIAL OR SIMILAR FONT, NON-BOLD <br />E. (MATERIAL) REFLECTIVE, WEATHER <br />RESISTANT MATERIAL SUITABLE FOR <br />THE ENVIRONMENT (USE UL 969 AS <br />STANDARD FOR WEATHER RATING) <br />DURABLE ADHESIVE MATERIALS <br />MEET THIS REQUIREMENT <br />SHEET NUMBER
The URL can be used to link to this page
Your browser does not support the video tag.