Laserfiche WebLink
Energize the System <br />a. Turn ON the AC disconnect or Circuit breaker <br />for the branch circuit. <br />b. Turn ON the main utili [y-grid AC circuit breaker. <br />Your system will start producing power after a <br />five-minute wait time <br />4 -0, status LED <br />0 4/ <br />: 2. <br />One minute after DC power is ap- <br />plied, the status LED on the under- <br />side of each M215 will blink green six <br />times to indicate normal start up. <br />Next Step <br />Refer to the Envoy Communications Gateway Quick <br />/nsta# Guide for inton-nation on Envoy® installation <br />and Enlighten® access. <br />Enphase Energy, Inc. <br />1420 N. McDowell:Blvd. <br />Petaluma,CA 94954 <br />USA <br />info@enphaseenergy.com C UShttp //www.enphase.com <br />12 <br />Step Details <br />0 <br />NOTE- Verify that,AC voltage at the site is within range: <br />240 volt AC Split Phase 208 Volt AC Three Phase <br />Ll to L2 211 te 264 VAC Ll to L.2 to L,3 1,83 to 229'VAC <br />Ll. I-2, to N 106 to 132 VAC: Ll,12, L3 to N 106 t0 132 VAC <br />WARNING: Only use: electrical system components approved <br />fer wet locations. <br />WARNING: Do NOT exceed the maximum number oi micro- <br />inverters In an AC branch circuk as listed in the table below. <br />Each breirch circuit must be protected by a dedicated circuit <br />breaker ot 20 A or less. <br />Service type Max M21 5s per branch <br />240 VAC split phase 17 <br />208 VAC three phase 25 <br />WARNING: Size the AC wire gauge ro account for voltage drop <br />for both the branch circuit and all upstream conductors eading <br />back to the FCC. See Circuit Ca/culations for M215 at http:// <br />www.eniphase.com/support. <br />0 <br />WARNING: Allow a minimum of 1.9 cm (0.75") between the <br />roof and the microinverter. Alse allow 1.3 cm (0.500 between the <br />back of the PV:module and the top of the microinverter. <br />NOTE: Torque the micfoinverter fastenets to the values shown. <br />Do not over torque: <br />• 6 mrn (1/4"l mounting hardware - 5. N m (45-50 in-lbs) <br />• 8 mill (5/16:') mounting hardware -9 N m (80-85 in-lbs) <br />Using a ipower screwdriver is not recommended due to the risk <br />of thread galling. <br />0 <br />NOIE: The:AC output neutral is not bonded to ground inside <br />the microinverter. <br />NOTE: The M215 grounding cleat can accommodate a 6 to 8 <br />AWG conductor. Toique the 10/32 grounding cleat screw to <br />2 N m (20-25 in-lbs). Do not over torque. Using a power scfew- <br />driver is not recommended due to the risk of thread galling. <br />0 <br />WARNING: Install sealing ca.ps on all unused AC connectors <br />as these become live when the system is <br />energized by the utility. The IP67-rated .il disconnect <br />scaling caps are required for 62#51 tool <br />protection against moisti re ingress. <br />NOTE: To remove a scaling cap, you <br />must use the Enphase disconnect tool or E•XJRT&1 <br />a #2 Phillips screwdriver.O<JI- <br />0 <br />NOTE: The Engage Cable uses the following wiring scheme. <br />240 Volt AC, Split Phase Wiring 208 Volt AC, Three Phase Wiring <br />Black - Ll Black - Ll <br />Red - L.2 Red - L2 <br />White - Neutral Blue - U <br />Green - Ground White - Neutral <br />Green - Ground <br />© 2013 Enphase Energy Inc. All rights reserved. <br />00