Planning & Building Agency <br />Building Safety Dlvision <br />20 Civic Center Plaza <br />P.o. Box 19EB (M.19) <br />Santa Ana, CA 92702 <br />(7r4) 647-5E00 <br />wwrY,santa-ana.org <br />RESIDENTIAL <br />PHOTOVOLTAIG <br />CHECKLIST <br />soL 01 cBc 2016 <br />Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only <br />lnstructions: The licensed contractor of record shall complete all sections, answer the ten questions and <br />sign the certification section below. A copy of this form shall be attached to each of TwO sets of plans, of <br />minimum 1 1" x 17" size. lf answerino NO to anv of ths ouo3tlons. plan check shall be reoulrod. <br />Proj ect Address: 1435 South Borchard Ave <br />Contractor Company Name: Vivint Solar <br />Contractor Licen56 11um5g1; 973756 <br />YES NO <br />1. BE <br />2 Elfl <br />3. Etr <br />4. gE <br />s. atr <br />6. Efl <br />7. EE <br />Are the following applicable to the proposed prolect? <br />Will the PV system layout provide the required three-foot wide clear access palhways <br />per Section 605.11 of the Califomia Fire Code, and is lhis shown on the roof plan? <br />Will the PV system be instelled on a roof having only one roofing layer with no <br />overlays? <br />Wall the PV anay be flush mounted to the existing roof so that the plane of the <br />modules (panels) are parallel to the plane of the roof? <br />Will the PV system weigh maximum 4 pounds per square feel or less? <br />Will the PV system be installed where ths modules do nol overhang any roof edgos <br />(such as eaves, gabled ends, ridges and hips)? <br />Will the PV system be installed with a space of 2" minimum to 10" maximum between <br />the underside of modules and the surface of lhe roof? <br />Will the PV system be installed without using any ballast system or counter-weight <br />system? <br />Will the anchors be installed with e maximum horizontal anchor spacing of 6 feet <br />and is this maximum horizontal spacing shown on the plans? <br />Will the minimum 5/16" lag screws be installed wilh a minimum ol2-112incl,t <br />embedment into roof raflers (with pre-drilled holes) and is this minimum emb€dment <br />shown on the plans? <br />Are ALL the structural pages of the plans stamped and signed by a California <br />licensed professional engineer? (including project specific site plan, PV layout, <br />anchorage spacing, anchorage details and manufacture/s PV support information.) <br />8 tr <br />o trtr <br />10.Eltr <br />I certlfy under ponalty of perjury undsr lhe laws of the State of C <br />py;n1 116r"- Noemi Brito Signature: <br />phone Number: 7 1 4-872-347 6 <br />Email Address: <br />Rev: 8/29/19 <br />noemi. brito@vivintsolar.com <br />9.s6. 4l22l2O <br />la that the ls true: <br />@-^---L