Laserfiche WebLink
3. Electrical Components: <br />A. Module (UL 1703 Listed) <br />Yingli Energy- YL.250P-29b <br />Qty <br />17 modules <br />Module Specs <br />Pmax - nonlinal >maximum powet: at STC <br />Vinp - rat:ed ve][age at maximum power <br />Voc - rated open-circuit voltage <br />Imp - rated current at maximum power <br />Ist- race ishort circuit current <br />250 watts <br />30.2 volts <br />37:8 vofts <br />8.11 amps <br />8.63 amps <br />B. Inverter (UL 1741 listed) <br />Enphast M215-60-2LL-S22 <br />Qty <br />17 inverters <br />Inverter Specs <br />1. Input Data (:DC in) <br />Recommended input power (DC) -260 ward <br />Max. input DC Voltage -45 volts <br />Peak power tracking vc)]rage -22V - 36V <br />Min./Max. start voirage -22V/45V <br />Max. DC shorr circuit current -15:imps <br />Max. inpuT current -10.5 amps <br />2. Output Data (AC Out) <br />Max. output power -215 watts <br />Norninal output current .0,9 amps <br />Nominal veltage 240 volts <br />Max. units per PV circuit -17 micro-inverters <br />Max. OCPD rating -20 amp circuit breaker <br />C. System Configuration <br />Numbeu: of'PV eireti'ts 1 <br />PV circuit 1 -17 modules/inverters (20) amp breaker <br />Vivint