Laserfiche WebLink
GENERAL NOTES <br />DATE: <br />P.M.: <br />DRAWN BY: <br />JOB NO.: <br />26081 Merit Cir, STE 111 <br />Laguna Hills, CA 92653 <br />909-257-7040 WWW.BNDESIGNBUILDINC.COM <br />THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN <br />DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK <br />EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. <br />D ES I GNBUILDCNI <br />6/ <br />1 <br />2 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />7 <br />: <br />0 <br />6 <br />: <br />4 <br />7 <br /> <br />P <br />M <br />A0.2 <br />B.N. <br />S.R. <br />GENERAL NOTES <br />06.10.2025 <br />202500149 <br />1517 W RAYMAR <br />ST, SANTA ANA, <br />CA 92703 <br />SINGLE <br />FAMILY HOME <br />GREEN CODE BUILDING <br />THE FLOOR SHALL BE CONCRETE SLAB ON GRADE AND SHALL BE A MINIMUM <br />OF FOUR-INCH (4 ”) (FIVE-INCH (5”) AT WATER TREATMENT ROOM) THICK WITH <br />MINIMUM CONCRETE STRENGTH OF 3,000-PSI. IT WILL INCLUDE ONE OF THE <br />FOLLOWING, WIRE MESH OR FIBER MESH, AND/OR REBAR REINFORCEMENT <br />OVER A 10 MILL MINIMUM VAPOR BARRIER (STEGO WRAP OR EQUAL) AND <br />GRANULAR FILL PER LESSOR'S SOILS AND/OR STRUCTURAL ENGINEERING <br />TEAM BASED ON SOIL CONDITIONS AND REPORT FROM THE SOILS ENGINEER. <br />FINISH FLOOR ELEVATION TO BE A MINIMUM OF 8" ABOVE FINISH GRADE. THE <br />SLAB SHALL INCLUDE PROPER EXPANSION CONTROL JOINTS. FLOOR SHALL <br />BE LEVEL (1/8” WITH 10’ OF RUN), SMOOTH, BROOM CLEAN WITH NO ADHESIVE <br />RESIDUES, IN A CONDITION THAT IS ACCEPTABLE TO INSTALL FLOOR <br />COVERINGS IN ACCORDANCE WITH THE FLOORING MANUFACTURER ’S <br />SPECIFICATIONS. <br />CONCRETE FLOOR SHALL BE CONSTRUCTED SO THAT NO MORE <br />THAN 3-LBS. OF MOISTURE PER 1,000SF/24 HOURS IS EMITTED PER <br />COMPLETED CALCIUM CHLORIDE TESTING RESULTS AFTER 28 DAY <br />CURE TIME. MEANS AND METHODS TO ACHIEVE THIS LEVEL WILL <br />BE RESPONSIBILITY OF THE LESSOR. LESSEE REQUIRES THAT <br />LESSOR PROVIDE MOISTURE CONTROL TREATMENT ADMIXTURE <br />(CONCURE ADMIXTURE, NO SUBSTITUTES – CONTACT EMIL PIKULA <br />OF CONCURE (480) 820-7171 FOR SPECIAL PRICING AND <br />PROCEDURES) IN THE MIX DESIGN. FLOOR SLAB SHALL BE CURED <br />ACCORDING TO ACI AND RESILIENT FLOORING INSTITUTE <br />GUIDELINES, WATER CURE OR EMPLOY THE USE OF CONCURE <br />2100 CURE AND SEAL. FLOORING CONTRACTOR SHALL ADDRESS <br />ALL CRACKS, EXPANSION JOINTS, SAW CUTS, ETC., USING <br />CONCURE 670 CRACK FILL BINDER. CONTACT CONCURE SYSTEMS <br />(480-820-7171) FOR APPROVAL AND METHOD FOR MOISTURE <br />TESTING. <br />CONCRETE SLAB NOTE <br />1. EACH APPLIANCE PROVIDED AND INSTALLED MEETS ENERGY <br />STAR IF AN ENERGY STAR DESIGNATION IS APPLICABLE FOR <br />THAT APPLIANCE. (GBC 4.506.1) <br />2. WHERE FUTURE SPACE FOR SOLAR IS REQUIRED, AN ELECTRICAL <br />CONDUIT SHALL BE PROVIDED FROM THE ELECTRICAL SERVICE <br />EQUIPMENT TO SUCH SPACE. THE CONDUIT SHALL BE ADEQUATELY <br />SIZED BY THE DESIGNER BUT SHALL NOT BE LESS THAN ONE INCH. <br />THE CONDUIT SHALL BE LABELED AS PER THE LOS ANGELES FIRE <br />DEPARTMENT REQUIREMENTS AND THE ELECTRICAL PANEL SHALL BE SIZED <br />TO ACCOMMODATE THE INSTALLATION OF A FUTURE ELECTRICAL SOLAR <br />SYSTEM. (4.211.4) <br />3. THE FLOW RATES FOR ALL PLUMBING FIXTURES SHALL COMPLY WITH THE <br />MINIMUM FLOW RATES IN TABLE 4.303.2/TABLE 9.403.2. (4.303.1) <br />4. WHEN SINGLE SHOWER FIXTURES ARE SERVED BY MORE THAN ONE <br />SHOWERHEAD, THE COMBINED FLOW RATE OF ALL THE SHOWERHEADS <br />SHALL NOT EXCEED THE MAXIMUM FLOW RATES SPECIFIED IN THE 20 <br />PERCENT REDUCTION COLUMN CONTAINED IN TABLE 4.303.2 OR THE <br />SHOWER SHALL BE DESIGNED TO ONLY ALLOW ONE SHOWERHEAD TO BE IN <br />OPERATION AT A TIME.(4.303.1.3.2) <br />5. INSTALLED AUTOMATIC IRRIGATION SYSTEM CONTROLLERS SHALL BE <br />WEATHER- OR SOIL-BASED CONTROLLERS. (4.304.2) <br />6. ANNULAR SPACES AROUND PIPES, ELECTRIC CABLES, CONDUITS, OR <br />OTHER OPENINGS IN PLATES AT EXTERIOR WALLS SHALL BE PROTECTED <br />AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENINGS WITH <br />CEMENT MORTAR, CONCRETE MASONRY, OR METAL PLATES. (4.406.1) <br />7. MATERIALS DELIVERED TO THE CONSTRUCTION SITE SHALL BE <br />PROTECTED FROM RAIN OR OTHER SOURCES OF MOISTURE.(4.407.4) <br />8. FOR ALL NEW EQUIPMENT, A COMPLETED OPERATION AND MAINTENANCE <br />MANUAL INCLUDING, AT A MINIMUM, THE ITEMS LISTED IN SECTION 4.410.1 OR <br />9.410.1, SHALL BE COMPLETED AND PLACES IN THE BUILDING AT THE TIME OF <br />FINAL INSPECTION. (4.410.1) <br />9. AT LEAST 50% OF ALL AREAS RECEIVING RESILIENT FLOORING SHALL <br />COMPLY WITH THE VOLATILE ORGANIC COMPOUND (VOC) LIMITS OR BE <br />CERTIFIED UNDER THE RESILIENT FLOOR COVERING (RCFI) FLOORSCORE <br />PROGRAM. (4.504.4) <br />10. ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT <br />OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, OR SHEET METAL UNTIL <br />THE FINAL STARTUP OF THE HEATING AND COOLING EQUIPMENT. (4.504.1) <br />11. DESIGNERURAL PAINTS AND COATINGS, ADHESIVES, CAULKS AND <br />SEALANTS SHALL COMPLY WITH THE VOLATILE ORGANIC <br />COMPOUND (VOC) LIMITS. (4.504.2.1) <br />12. THE VOC CONTENT VERIFICATION CHECKLIST, FORM GRN 2, <br />SHALL BE COMPLETED AND VERIFIED PRIOR TO FINAL INSPECTION <br />APPROVAL. THE MANUFACTURER ’S SPECIFICATIONS SHOWING <br />VOC CONTENT FOR ALL APPLICABLE PRODUCTS SHALL BE READILY <br />AVAILABLE AT THE JOB SITE AND BE PROVIDED TO THE FIELD INSPECTOR <br />FOR VERIFICATION. (4.504.2.4) <br />13. THE FORMALDEHYDE EMISSIONS VERIFICATION CHECKLIST, <br />FORM GRN 3, SHALL BE COMPLETED PRIOR TO FINAL INSPECTION <br />APPROVAL. THE MANUFACTURER ’S SPECIFICATIONS SHOWING <br />FORMALDEHYDE CONTENT FOR ALL APPLICABLE WOOD PRODUCTS <br />SHALL BE READILY AVAILABLE AT THE JOB SITE AND BE PROVIDED TO THE <br />FIELD INSPECTOR FOR VERIFICATION. (4.504.5) <br />14. ALL NEW CARPET INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE <br />TESTING AND PRODUCT REQUIREMENTS OF ONE OF THE FOLLOWING: <br /> A. CARPET AND RUG INSTITUTE ’S GREEN LABEL PLUS PROGRAM <br /> B. CALIFORNIA DEPARTMENT OF PUBLIC HEALTH STANDARD <br /> PRACTICE FOR THE TESTING OF VOCS (SPECIFICATION01350) <br /> C. NSF/ANSI 140 AT THE GOLD LEVEL <br /> D. SCIENTIFIC CERTIFICATIONS SYSTEMS INDOOR ADVANTAGE™ GOLD <br />(4.504.3) <br />15. ALL NEW CARPET CUSHION INSTALLED IN THE BUILDING INTERIOR SHALL <br />MEET THE REQUIREMENTS OF THE CARPET AND RUG INSTITUTE GREEN <br />LABEL PROGRAM. (4.504.3) <br />16. BUILDING MATERIALS WITH VISIBLE SIGNS OF WATER DAMAGE <br />SHALL NOT BE INSTALLED. WALL AND FLOOR FRAMING SHALL NOT BE <br />ENCLOSED UNTIL IT IS INSPECTED AND FOUND TO BE SATISFACTORY BY THE <br />BUILDING INSPECTOR. (4.505.3) <br />17. BATHROOM EXHAUST FANS SHALL BE ENERGY STAR COMPLIANT AND BE <br />DUCTED TO TERMINATE TO THE OUTSIDE OF THE BUILDING. (4.506.1) <br />18. BATHROOM EXHAUST FANS, NOT FUNCTIONING AS A COMPONENT OF A <br />WHOLE HOUSE VENTILATION SYSTEM, MUST BE CONTROLLED BY A <br />HUMIDISTAT WHICH SHALL BE READILY ACCESSIBLE. (4.506.1) <br />19. THE SIZE AND LAYOUT OF THE HEATING AND AIR-CONDITIONING <br />SYSTEMS SHALL BE IN ACCORDANCE WITH ACCA MANUAL J, ACCA 29-D AND <br />ACCA 36-S, ASHRAE HANDBOOKS. (4.507.2 <br />1. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND <br />UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITY <br />(POWER POLES, PULL-BOXES, TRANSFORMERS, VAULTS, PUMPS, <br />VALVES, METERS, APPURTENANCES, ETC.) OR TO THE LOCATION OF THE <br />HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY <br />POWER LINES -WHETHER OR NOT THE LINES ARE LOCATED ON THE <br />PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS <br />AND/OR ADDITIONAL EXPENSES.” <br />2. OBTAIN PERMITS FROM PUBLIC WORKS PRIOR TO CONSTRUCTION FOR: <br />A. TEMPORARY PEDESTRIAN PROTECTION AS REQUIRED. FOR ANY <br />CONSTRUCTION NEAR ANY STREET OR PUBLIC AREA. <br />3. OUTLETS ALONG WALL COUNTER SPACE, ISLAND AND PENINSULA <br />COUNTER SPACE IN KITCHENS SHALL HAVE A MAXIMUM SPACING OF 48". <br />(210-52 NEC) <br />4. THE FIRST LIGHT IN THE NEW AND REMODELED BATHROOMS AND KITCHEN <br />SHALL BE AN ENERGY EFFICIENT LIGHT MEETING A MINIMUM OF 40 LUMENS <br />PER WATT (E.G. FLUORESCENT LAMP). (T-24, SEC. 130(B) & 150(K)) <br />5. EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED <br />WITH NATURAL LIGHT BY MEANS OF EXTERIOR GLAZED OPENINGS IN <br />ACCORDANCE WITH SECTION R303.1 OR SHALL BE PROVIDED WITH <br />ARTIFICIAL LIGHT THAT IS ADEQUATE TO PROVIDE AN AVERAGE <br />ILLUMINATION OF 6 FOOT-CANDLES OVER THE AREA OF THE ROOM AT A <br />HEIGHT OF 30 INCHES ABOVE THE FLOOR LEVEL. (R303.1) <br />6. KITCHEN SINKS, LAVATORIES, BATHTUBS, SHOWERS, BIDETS, LAUNDRY <br />TUBS AND WASHING MACHINE OUTLETS SHALL BE PROVIDED WITH HOT AND <br />COLD WATER AND CONNECTED TO AN APPROVED WATER SUPPLY (CRC <br />R306.4.) <br />7. FINISH MATERIALS INCLUDING ADHESIVES, SEALANTS, CAULKS, PAINTS <br />AND COATING, AEROSOL PAINTS AND SYSTEMS AND COMPOSITE WOOD <br />PRODUCTS SHALL MEET THE VOLATILE ORGANIC COMPOUND (VOC) <br />EMISSION LIMITS IN ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING <br />STANDARDS CODE, CHAPTER 4 DIVISION 4.5. (R330) <br />8. WHEN A VAPOR RETARDER IS REQUIRED, A CAPILLARY BREAK SHALL BE <br />INSTALLED IN ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING <br />STANDARDS CODE, CHAPTER 4, DIVISION 4.5. (R506.2.3.1) <br />9. ANNULAR SPACE AROUND PIPES, ELECTRIC CABLES, CONDUITS OR OTHER <br />OPENINGS IN BOTTOM/SOLE PLATES AT EXTERIOR WALLS SHALL BE <br />PROTECTED AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH <br />OPENINGS IN ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING <br />STANDARDS CODE, CHAPTER 4, DIVISION 4.4. (R602.3.4.1) <br /> BATHROOMS <br />1. ALL SHOWER ENCLOSURES, REGARDLESS OF SHAPE, SHALL HAVE A <br />MINIMUM 22" CLEARANCE AND FINISHED INTERIOR AREA OF NOT LESS THAN <br />1024 SQUARE INCHES (0.66 M2 ) AND SHALL BE CAPABLE OF ENCOMPASSING <br />A 30 INCH DIAMETER (0.76 M) CIRCLE. THE MINIMUM AREA AND DIMENSIONS <br />SHALL BE MAINTAINED TO A POINT 70 INCHES (1.8 M) ABOVE THE SHOWER <br />DRAIN OUTLET. (CPC 410.4) <br />2. BATHTUB AND SHOWER FLOORS, WALLS ABOVE BATHTUBS WITH A <br />SHOWERHEAD, AND SHOWER COMPARTMENTS SHALL BE FINISHED WITH A <br />NONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A <br />HEIGHT OF NOT LESS THAN 6 FEET ABOVE THE FLOOR (R307.2). <br />3. PROVIDE ULTRA LOW FLUSH WATER CLOSETS FOR ALL NEW <br />CONSTRUCTION. EXISTING SHOWER HEADS AND TOILETS MUST BE ADAPTED <br />FOR LOW WATER CONSUMPTION. <br />4. A MIN 12" SQ. ACCESS PANEL TO THE BATHTUB TRAP SLIP JOINT <br />CONNECTION IS REQUIRED. (PLUMBING CODE SECTION 405.2) <br />LAUNDRY ROOM <br />1. CLOTHES DRYER(S) LOCATED IN AN AREA THAT IS HABITABLE OR <br />CONTAINING FUEL BURNING APPLIANCES SHALL BE EXHAUSTED TO THE <br />OUTSIDE OR TO AN AREA WHICH IS NOT HABITABLE AND DOES NOT CONTAIN <br />OTHER FUEL BURNING APPLIANCES (BUT NOT BENEATH THE BUILDING OR IN <br />THEATTIC AREA). (M.C. 504.3.1) <br />MEANS OF EGRESS <br />1. PROVIDE 32" WIDE DOORS TO ALL INTERIOR ACCESSIBLE ROOMS WITHIN A <br />DWELLING UNIT. <br />2. PROVIDE EMERGENCY EGRESS FROM SLEEPING ROOMS. MIN.- 24" CLEAR <br />HT, 20" CLEAR WIDTH, 5.7 SQ.FT. MIN. AREA. <br /> <br />GRADING AND FOUNDATION <br />1. IF ADVERSE SOIL CONDITIONS ARE ENCOUNTERED, A SOILS INVESTIGATION <br />REPORT MAY BE REQUIRED. <br />2. FOUNDATION AND FLOOR SLABS SHALL CONFORM TO THE FOLLOWING OR <br />THE RECOMMENDATION OF AN APPROVED SOILS REPORT : <br /> A. DEPTH OF FOOTINGS BELOW THE NATURAL AND FINISHED GRADES SHALL <br /> NOT BE LESS THAN 18 INCHES FOR EXTERIOR AND SEE <br /> STRUCTURALFOUNDATION PLAN FOR INTERIOR FOOTINGS. <br /> B. EXTERIOR WALLS AND INTERIOR BEARING WALLS SHALL BE SUPPORTED <br /> ON CONTINUOUS FOOTINGS. <br /> C. FOOTINGS SHALL BE REINFORCED WITH A MINIMUM 4 - ½ -INCH DIAMETER <br /> DEFORMED REINFORCING BARS. TWO BARS SHALL BE PLACED WITHIN 4 <br /> INCHES OF THE BOTTOM OF THE FOOTING AND TWO BARS WITHIN 4 INCHES <br /> OF THE TOP OF THE FOOTINGS. <br /> D. THE SOIL BELOW AN INTERIOR CONCRETE SLAB SHALL BE SATURATED <br /> WITH MOISTURE TO A DEPTH OF 18 INCHES PRIOR TO PLACING THE <br /> CONCRETE. <br /> E. CONCRETE FLOOR SLABS ON GRADE SHALL BE PLACED ON A 4" FILL OF <br /> COARSE AGGREGATE OR ON A MOISTURE BARRIER MEMBRANE. THE SLABS <br /> SHALL BE AT LEAST 3½ INCH THICK AND SHALL BE REINFORCED WITH #4 <br /> REBARS AT 16 INCH ON CENTER IN BOTH DIRECTIONS. <br />3. CONCRETE SLABS ON EXPANSIVE SOIL, COMPACTED FILL OR SLOPES OVER <br />1:10 SHALL BE PLACED ON A 4-INCH FILL OF COARSE AGGREGATE OR ON A <br />BED COVERED MOISTURE BARRIER MEMBRANE. <br />4. OPENINGS SHALL BE AS CLOSE TO CORNERS AS PRACTICABLE AND SHALL <br />PROVIDE CROSS VENTILATION ALONG THE LENGTH OF AT LEAST TWO <br />OPPOSITE SIDES. OPENING SHALL HAVE 1/4 INCH CORROSION RESISTANT <br />METAL MESH COVERING. <br />5. PROVIDE CORROSION RESISTANT WEEP SCREED BELOW THE STUCCO A <br />MINIMUM OF 4" ABOVE EARTH OR 2" ABOVE PAVED AREA. <br />6. PROVIDE RAIN GUTTERS AND CONVEY RAIN WATER TO THE STREET. <br />7. SMOKE DETECTORS SHALL BE PROVIDED FOR ALL DWELLING UNITS <br />INTENDED FOR HUMAN OCCUPANCY, UPON THE OWNER ’S APPLICATION FOR <br />A PERMIT FOR ALTERATIONS, REPAIRS, OR ADDITIONS, EXCEEDING ONE <br />THOUSAND DOLLARS ($1,000). (R314.6.2) <br />8. AN APPROVED SMOKE ALARM SHALL BE INSTALLED IN EACH SLEEPING <br />ROOM & HALLWAY OR AREA GIVING ACCESS TO A SLEEPING ROOM, AND ON <br />EACH STORY AND BASEMENT FOR DWELLINGS WITH MORE THAN ONE STORY. <br />SMOKE ALARMS SHALL BE INTERCONNECTED SO THAT ACTUATION OF ONE <br />ALARM WILL ACTIVATE ALL THE ALARMS WITHIN THE INDIVIDUAL DWELLING <br />UNIT. IN NEW CONSTRUCTION SMOKE ALARMS SHALL RECEIVE THEIR <br />PRIMARY POWER SOURCE FROM THE BUILDING WIRING AND SHALL BE <br />EQUIPPED WITH BATTERY BACK UP AND LOW BATTERY SIGNAL. (R314) <br />1.TERMINATION OF ALL ENVIRONMENTAL AIR DUCTS (E.G., DRYERS, <br />BATH FANS, RANGE VENTS, ETC.) SHALL BE AT LEAST 3 FEET FROM <br />OPENINGS INTO THE BUILDING AND EQUIPED W/ A BACK-DRAFT <br />DAMPER. VENT DUCTS MAY BE COMBINED AND VENT AT ROOF BUT <br />CONSULT DESIGNER FOR LOCATION. <br />2.ALL VENTING FANS IN BATHROOMS CONTAINING A BATHTUB, <br />SHOWER, AND SPAS SHALL BE CONTROLLED BY A HUMIDISTAT AND BE <br />ENERGY STAR RATED. <br />3.ALL BATHROOMS CONTAINING A BATHTUB, SHOWER, SPA, AND <br />SIMILAR FIXTURES SHALL BE MECHANICALLY VENTED PER CMC, CAL. <br />ENERGY CODE AND ASHARE 62.2. THE MECHANICAL FAN SHALL VENT <br />ONE C.F.M. PER ONE SF OF AREA WITH A MIN. FAN SIZE OF 50 C.F.M. <br /> a.WITH A 50 CFM FAN, USE 4 ” DIAM. FLEX VENT PIPE WITH A MAX. <br /> LENGTH OF 70’ <br /> b.WITH AN 80 CFM FAN, USE 5 ” DIAM. FLEX VENT PIPE WITH A MAX. <br /> LENGTH OF 70’ <br />4.ALL FANS INSTALLED TO MEET ALL OF THE PRECEDING <br />REQUIREMENTS MUST BE SPECIFIED AT A NOISE RATING OF A MAXIMUM <br />1 “SONE” (FOR THE CONTINUOUS USE CALCULATION) OR 3 “SONE” (FOR <br />THE INTERMITTENT USE CALCULATION). <br />5.EVERY KITCHEN SHALL HAVE HOOD TO THE OUTSIDE OF THE <br />BUILDING W/ MIN. LESS THAN 750 SF REQUIRES 85% CE OR 280 CFM . <br />6” DIAM. EQUIPPED WITH BACKDRAFT DAMPER, THAT HAS A MAXIMUM <br />SOUND RATING OF 3-SONES AND THE REQUIREMENT FOR HERS <br />VERIFICATION. <br />6.ALL NEW FIREPLACES SHALL BE DIRECT VENT, SEALED COMBUSTION, <br />CLOSEABLE DOORS, WITH OUTSIDE AIR INTAKE <br />7.ANY EXISTING NON-EPA PHASE TWO WOOD BURNING FIREPLACE <br />WILL BE REPLACED WITH A PHASE II CERTIFIED GAS UNIT FIREPLACE <br />(M.C.C 19.80.080) OR CONVERTED TO A DEDICATED GAS LOG FIREPLACE <br />PER CODE. <br />8.PRE-FABRICATED FIREPLACE INSTALLATION INSTRUCTIONS ARE TO <br />BE ON THE JOB SITE AT THE TIME OF INSPECTION. FACTORY BUILT <br />FIREPLACES MUST BE INSTALLED IN STRICT ACCORDANCE WITH THE <br />MANUFACTURERS SPECIFICATIONS & INSTRUCTIONS AND ESR - 2401. <br />9.GENERAL CONTRATOR TO PROVIDE GAS LINE TO EXTERIOR <br />FIREPLACE FIRE BOX AND GAS LIGHTER SWITCH. INSTALL IN COMPLETE <br />ACCORDANCE W/ ALL LOCAL & STATE BLDG. CODE REQUIREMENTS. <br />FIREPLACE GAS OUTLET "LOG LIGHTER" CONTROL VALVES SHALL BE <br />LOCATED OUTSIDE THE MINIMUM REQUIRED HEARTH AREA & WITHIN 4 <br />FEET MAXIMUM FROM THE OUTLET, PER CPC 1211.17. <br />10.PER CALGREEN SECTION 4.503.1, GAS FIREPLACES SHALL BE DIRECT- <br />VENT AND SEALED-COMBUSTION TYPE. PER CAL. ENERGY CODE <br />SECTION 150.0(E)1, GAS FIREPLACES SHALL BE PROVIDED WITH <br />CLOSEABLE DOORS AND OUTSIDE COMBUSTION INTAKE WITH DAMPER <br />OR COMBUSTION AIR CONTROL DEVICE WHEN LOCATED ON AN <br />EXTERIOR WALL. FIREPLACE INSTALLATION AND VENTING SYSTEM MUST <br />CONFORM TO STANDARD ANSI Z21.88b 2008 CSA 2.33a 2008 VENTED GAS <br />FIREPLACE HEATERS AND NATIONAL FUEL GAS CODE, Z223.1, LATEST <br />EDITION. <br />11.NON-COMBUSTIBLE BACKER BOARD MUST BE USED TO SHEET IN <br />FRONT OF THE FIREPLACE EXTENDING A MIN. 6" BELOW, 12" ABOVE & 10" <br />AT SIDES. STANDARD SHEET ROCK MAY BE USED BEYOND THIS POINT IF <br />PER MANUF. RQMTS. BACKER BOARD MATERIALS SHALL MEET CRC <br />TABLE R702.4.2 STANDARDS, SUCH AS ASTM C1178 FOR GLASS MAT <br />BACKING PANELS AND ASTM C1288 FOR FIBER-CEMENT BACKER BOARD. <br />12. PROVIDE ADEQUATE COMBUSTION AIR FOR FUEL-BURNING <br />APPLIANCES AND WATER HEATERS WITH OPENING SHALL HAVE A FREE <br />AREA OF NOT LESS THAN 1 SQUARE INCH PER 1000 BTU/H (0.002 M2/KW) <br />OF THE TOTAL INPUT RATING OF APPLIANCES IN THE SPACE, BUT NOT <br />LESS THAN 100 SQUARE INCHES (0.065 M2). ONE OPENING SHALL <br />COMMENCE WITHIN 12 INCHES OF THE TOP OF THE ENCLOSURE, AND <br />ONE OPENING SHALL COMMENCE WITHIN 12 INCHES OF THE BOTTOM <br />OF THE ENCLOSURE (SEE FIGURE 701.5). THE DIMENSION OF AIR <br />OPENINGS SHALL BE NOT LESS THAN 3 INCHES .IT MUST HAVE <br />ADEQUATE VOLUME VOLUME SHALL BE NOT LESS THAN 50 CUBIC FEET <br />PER 1000 BRITISH THERMAL UNITS PER HOUR (BTU/H) (4.83 M3/KW). <br />TOTAL INPUT; ALL DOORS CLOSED). SCREENS SHALL BE NOT LESS <br />THAN 1/4 OF AN INCH (6.4 MM) MESH. [NFPA 54:9.3.7.2] PER 2022 CMC, <br />Section 701. <br />13.IF FURNACE OR WATER HEATER IS IN CRAWL SPACE THE APPLIANCE <br />SHALL BE ON A NON-COMBUSTABLE FLOORING OR SLAB FOR <br />MOUNTING OR ANCHORAGE W/ A MIN. 3 ” ABOVE GRADE AND LOCATED <br />NO MORE THAN 20 ’ FROM ACCESS OPENING. EQUIPMENT SUPPORTED <br />FROM ABOVE MUST HAVE 6 ” CLEAR ABOVE FINISH GRADE. <br />14.PROVIDE UNOBSTRUCTED PASSAGE WAY W/ SOLID FLOORING MIN. <br />24” WIDE BTWN ACCESS OPENING AND EQUIPMENT AND A 30 ” X 30” <br />PLATFORM ON SERVICE SIDE OF THE EQUIPMENT UNLESS THE <br />EQUIPMENT CAN BE SERVICED FROM THE ACCESS ENTRANCE. <br />15.HVAC SYSTEM DESIGN AND SIZING SHALL MEET CALGREEN SECTION <br />4.507.2 REQUIREMENTS. HEATING AND AIR CONDITIONING SYSTEMS <br />SHALL BE SIZED, DESIGNED, AND EQUIPMENT SELECTED USING THE <br />FOLLOWING METHODS: <br /> a.THE HEAT LOSS AND HEAT GAIN IS ESTABLISHED ACCORDING TO <br /> ANSI/ACCA 2 MANUAL J – <br /> (RESIDENTIAL LOAD CALCULATION), ASHRAE HANDBOOKS OR OTHER <br /> EQUIVALENT DESIGN SOFTWARE OR METHODS. <br /> b.DUCT SYSTEMS ARE SIZED ACCORDING TO ANSI/ACCA 1 MANUAL D – <br /> 2014 (RESIDENTIAL DUCT SYSTEMS), ASHRAE HANDBOOKS OR OTHER <br /> EQUIVALENT DESIGN SOFTWARE OR METHODS. <br /> c.SELECT HEATING AND COOLING EQUIPMENT ACCORDING TO <br /> ANSI/ACCA 3 MANUAL S – 2014 (RESIDENTIAL EQUIPMENT SELECTION) <br /> OR OTHER EQUIVALENT DESIGN SOFTWARE OR METHODS. <br /> EXCEPTION: USE OF ALTERNATE DESIGN TEMPERATURES NECESSARY <br /> TO ENSURE THE SYSTEMS <br /> FUNCTIONS ARE ACCEPTABLE. <br />MECHANICAL NOTES (MN): <br />1.THE CONTRACTOR SHALL, IN WRITING, CALL TO THE ATTENTION OF THE <br />DESIGNER ANY DISCREPANCIES BETWEEN SPECIFICATIONS, PLANS, <br />DETAILS OR SCHEDULES. THE DESIGNER WILL THEN INFORM THE <br />CONTRACTOR, IN WRITING, WHICH DOCUMENT TAKES PRECEDENCE. <br />2.FAILURE TO REPORT A CONFLICT IN THE CONTRACT DOCUMENTS <br />SHALL BE DEEMED EVIDENCE THAT THE CONTRACTOR HAS ELECTED TO <br />PROCEED IN THE MORE EXPENSIVE MANNER. <br />3.THE CONTRACTOR SHALL INVESTIGATE, VERIFY AND BE RESPONSIBLE <br />FOR ALL CONDITIONS AND DIMENSIONS OF THE PROJECT AND SHALL <br />NOTIFY THE DESIGNER ABOUT CONDITIONS REQUIRING MODIFICATION <br />BEFORE PROCEEDING WITH WORK. <br />4.DIMENSIONS: <br /> a.IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY ALL <br /> DIMENSIONS AND CONDITIONS AT THE JOB SITE AND TO CROSS CHECK <br /> DETAILS AND DIMENSIONS SHOWN ON THE OVERALL DRAWINGS WITH <br /> RELATED REQUIREMENTS ON THE STRUCTURAL, MECHANICAL, AND <br /> ELECTRICAL PLANS <br /> b.USE DIMENSIONS SHOWN RATHER THAN SCALING DRAWINGS. <br /> c.ALL DIMENSIONS SHOWN ARE F.O.S. (FACE OF STUD) UNLESS <br /> CENTERLINE IS SHOWN. <br /> d.ALL DIMENSIONS ARE TO THE ROUGH UNLESS OTHERWISE SHOWN. <br /> e.CEILING HEIGHT DIMENSIONS ARE FROM FINISHED FLOOR TO FINISH <br /> FACE OF CEILING. <br /> f.ALL DIMENSIONS SHALL BE VERIFIED IN THE FIELD BEFORE <br /> PROCEEDING WITH THE WORK. <br />5.PRIOR TO THE START OF CONSTRUCTION, PROPERTY LINES MUST BE <br />SURVEYED. PRIOR TO FOUNDATION INSPECTION, SETBACK STAKES MUST <br />BE ESTABLISHED BY A LICENSED LAND SURVEYOR OR CIVIL ENGINEER TO <br />ENSURE THAT NEW CONSTRUCTION IS LOCATED IN ACCORDANCE WITH <br />THE APPROVED PLANS. <br />6.PROVIDE ALL NECESSARY ANCHORAGE BLOCKING, BACKING AND <br />FRAMING NOT NECESSARILY LIMITED TO THE INSTALLATION OF LIGHT <br />FIXTURES, FIRE EXTINGUISHERS, TOILET ACCESSORIES, BRACKETS, <br />HANDICAP EQUIPMENT, AND TOILET PARTITIONS. <br />7.ALL DOORS NOT LOCATED BY DIMENSION ON PLAN OR DETAIL SHALL BE <br />5” FROM FACE OF STUD TO FACE OF NEAREST DOOR BUCK OR CENTERED <br />ON ROOM. <br />8.DOOR SIZES INDICATED ON THE DRAWINGS ARE OPENING DIMENSIONS; <br />ALLOWANCES FOR THRESHOLDS, ETC. SHALL BE TAKEN FOR NET DOOR <br />SIZES. <br />9.DETAILS MARKED TYPICAL (TYP.) SHALL APPLY IN ALL CASES UNLESS <br />SPECIFICALLY INDICATED OTHERWISE. <br />10.WHERE NO SPECIFIC DETAIL IS SHOWN THE FRAMING OR <br />CONSTRUCTION SHALL BE IDENTICAL OR SIMILAR TO THAT INDICATED FOR <br />LIKE CASES OF CONSTRUCTION ON THIS PROJECT. <br />11.THE CONTRACT DOCUMENTS INCLUDE THE OWNER / CONTRACTOR <br />CONTRACT, THE PROJECT MANUAL, DESIGN SPECIFICATIONS, APPROVED <br />SHOP DRAWINGS, THESE DRAWINGS, AND ANY DRAWINGS PROVIDED BY <br />INTERIOR DESIGNERS ASSOCIATED WITH THE PROJECT. <br />12.TEMPORARY NUMBERS MUST BE INSTALLED DURING CONSTRUCTION. <br />13.SKYLIGHT MANUF. TO BE “VELUX” <br />14.EACH EMERGENCY ESCAPE WINDOW ON THE FLOOR PLAN SHALL BE <br />LABELED. EMERGENCY ESCAPE WINDOWS SHALL HAVE A MINIMUM NET <br />CLEAR OPENING OF 5.7 SF. THE NET CLEAR OPEN HEIGHT SHALL BE 24 ” <br />AND WIDTH SHALL BE 20 ” DURING NORMAL OPERATION OF THE OPENING. <br />THE EMERGENCY ESCAPE OPENING SHALL HAVE THE BOTTOM OF THE <br />CLEAR OPENING NO HIGHER THAN 44 ” ABOVE THE FLOOR. <br />15.TEMPERED SAFETY GLAZING IS REQUIRED AT HAZARDOUS LOCATIONS. <br />TEMPERED GLAZING IS REQUIRED: <br /> a.IN BOTH PANES OF FRENCH DOORS, <br /> b.ADJACENT TO DOORS WHERE WINDOW IS W/IN 24 ” ARC OF EITHER <br /> VERTICAL EDGE OF A DOOR IN A CLOSED POSITION AND LESS THAN 60 ” <br /> ABOVE A WALKING SURFACE. MEASUREMENTS ARE FROM THE NEAREST <br /> EXPOSED EDGE OF GLASS. (SEE EXCEPTIONS) <br /> c.IN SHOWERS AND BATHTUBS ENCLOSURES INCLUDING WINDOWS IF <br /> BOTTOM IS LESS THAN 60 ” ABV. STANDING SURFACE. <br /> d.ADJACENT TO STAIRS, LANDINGS AND RAMPS WITHIN 36 ” <br /> HORIZONTALLY OF A WALKING SURFACE, IF WITHIN 36 ” ABOVE THE PLANE <br /> OF THE WALKING SURFACE. C R C §R 308 (ALL MEASUREMENTS ARE TO <br /> NEAREST EXPOSED EDGE OF GLASS) <br /> e.ALL EXTERIOR GLAZING PANES ARE REQUIRED TO BE TEMPERED WHEN <br /> STRUCTURE IS SUBJECT TO W.U.I. GUIDELINES. <br />16.OPERABLE WINDOWS ON UPPER FLOORS MUST BE AT LEAST 36 ’’ FROM <br />THE FLOOR WALKING SURFACE. OTHERWISE PROVIDE FALL PROTECTION <br />FOR THE WINDOWS PER CRC R312.1. THE INTERMEDIATE RAILING TO BE <br />SPACED SUCH THAT A 4 ’’ DIAMETER SPHERE CANNOT PASS THROUGH. <br />17.ADDITION: VENT ATTICS AND ENCLOSED RAFTER SPACES W/ 1/150 OF <br />AREA AT EAVES – PROVIDE AT LEAST 1” AIRSPACE BETWEEN INSULATION <br />AND PLYWD. SHEATHING OR VENT SPACE W/ 1/300 OF ATTIC SPACE W/ AT <br />LEAST 40% BUT NOT MORE THAN 50% OF REQUIRED VENTILATION AREA <br />PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE <br />ATTIC OR RAFTER SPACE AND NOT MORE THAN 3 ’ BELOW THE RIDGE OR <br />HIGHEST POINT OF THE SPACE. <br />18. EXISTING ATTIC VENTS: VENT ALL ATTICS AND ENCLOSED RAFTER <br />SPACES W/ 1/150 OF AREA AT EAVES – PROVIDE AT LEAST 1” AIRSPACE <br />BETWEEN INSULATION AND PLYWD. SHEATHING OR VENT SPACE W/ 1/300 <br />OF ATTIC SPACE W/ AT LEAST 40% BUT NOT MORE THAN 50% OF REQUIRED <br />VENTILATION AREA PROVIDED BY VENTILATORS LOCATED IN THE UPPER <br />PORTION OF THE ATTIC OR RAFTER SPACE AND NOT MORE THAN 3 ’ BELOW <br />THE RIDGE OR HIGHEST POINT OF THE SPACE. <br />19. VENTILATION OPENINGS FOR ENCLOSED ATTICS, ENCLOSED EAVE <br />SOFFIT SPACES, ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS <br />ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS, AND <br />UNDERFLOOR VENTILATION OPENINGS SHALL BE FULLY COVERED WITH <br />NON-CORROSIVE METAL WIRE MESH WITH OPENINGS A MINIMUM OF 1/16 ” <br />(1.6 MM) AND NOT EXCEED 1/8 ” <br />20.PROVIDE ATTIC AND UNDER-STORY ACCESS LARGE ENOUGH TO <br />REPLACE / REMOVE EQUIPMENT BUT NOT LESS THAN 22 ” X 30” WITH 30” <br />HEADROOM W/ WEATHER STRIPS TO PREVENT BACK DRAFT. <br />21.ALL STAIRWAYS SHALL HAVE A 36” MIN. WIDTH AND 36 ” MIN. LANDING OR <br />FLOOR AT THE TOP AND BOTTOM. ALSO A MAX. RISE OF 7 ¾” / MIN. RUN OF <br />10” MEASURED FROM THE NOSING (11 ” WHERE NO NOSING). STAIRS SHALL <br />HAVE HANDRAILS ON EA. SIDE WITH A MIN. HEIGHT OF 34 ” AND A MAX. OF <br />38” WITH A GRASPABLE DIAMETER OF 1.25 ” MIN. AND 2” MAX. <br />1.PROVIDE A NON-REMOVABLE BACKFLOW PREVENTION DEVICE ON <br />ALL EXTERIOR HOSE BIBS, AND LAWN SPRINKLER / IRRIGATION <br />SYSTEMS. <br />2.INSTALL A SEISMIC SHUT-OFF VALVE AT GAS METER IF NONE EXIST. <br />3.USE COPPER PIPE ONLY FOR WATER SUPPLY PIPES. IN 1 AND 2- <br />STORY BUILDINGS USE CAST IRON FOR WASTE LINE VERTICAL DROPS <br />AND BTWN FLOORS OVER LIVING SPACE TO REDUCE SOUND AND ABS <br />PLASTIC FOR VENTS. PLASTIC PIPING IS NOT ALLOWED IN 3 OR MORE <br />STORY BLDG. <br />4.THE MINIMUM SLOPE FOR SANITARY LINES IS ¼” / FT <br />5.EA. PLUMBING VENT SHALL TERMINATE NOT LESS THAN 10 ’ FROM, OR <br />AT LEAST 3’ ABOVE ANY OPERABLE WINDOW, DOOR, OPENING, OR AIR <br />INTAKE. COMBINE PLUMBING VENTS AND TERMINATE ON THE NORTH <br />FACING ROOF PLANE WHERE POSSIBLE TO AVOID IMPACT ON FUTURE <br />SOLAR PANEL INSTALLATIONS. LOOP VENTS TO CONFORM TO CPC <br />Section 909.1 <br />6.PROVIDE ACCESS TO ALL PLUMBING CLEAN-OUTS INCLUDING THOSE <br />UNDER FLOORS. <br />7.WATER HEATER IS TO HAVE A PRESSURE RELIEF VALVE AND DRAIN <br />PIPE SLOPING DOWNWARD TO THE EXTERIOR OF THE BUILDING W/ <br />TERMINATION DOWNWARD. CONDENSATE DRAIN LINE TERMINATION <br />FOR TANKLESS WATER HEATERS AND HVAC EQUIPMENT SHALL <br />COMPLY WITH CPC SECTION 814.1 REQUIREMENTS. <br />8.ANY NEW WATER HEATER MUST COMPLY WITH THE REQUIRED “FIRST <br />HOUR RATING ” FOR THIS PROJECT PER CPC 501.0 AND TABLE 5-1. <br />9.FOR A WATER HEATER LOCATED IN AN ATTIC OR SPACE WHERE <br />DAMAGE MIGHT RESULT FROM A LEAKING WATER HEATER, A <br />WATERTIGHT PAN OF CORROSION RESISTANT MATERIAL SHALL BE <br />INSTALLED BENEATH THE WATER HEATER W/ A MIN. ¾” DIAM. DRAIN TO <br />AN APPROVED LOCATION. <br />10.WHERE A BACKFLOW PREVENTION DEVICES ARE INSTALLED, AN <br />APPROVED EXPANSION TANK SHALL BE INSTALLED AT THE WATER <br />HEATER. <br />11.APPLIANCES SHALL BE ACCESSIBLE FOR INSPECTION, SERVICE, <br />REPAIR AND REPLACEMENT WITHOUT REMOVING PERMANENT <br />CONSTRUCTION. A 30” X 30” PLATFORM OR S.O.G. SHALL BE PROVIDED <br />IN FRONT OF THE APPLIANCE. <br />12.INSTALL APPROVED AIR GAP FITTING AT DISHWASHER TO WASTE <br />CONNECTION PER CPC SEC. 807.3. <br />13.WATER CLOSET AND BIDETS MUST HAVE A MIN. OF 15 ” FROM CENTER <br />CLEAR ON EA. SIDE AND 24 ” CLEAR IN FRONT. <br />14.ALL NEW AND EXISTING PLUMBING FIXTURES SHALL COMPLY TO <br />ADOPTED CODE FOR WATER CONSERVATION REQMTS. <br /> a.TOILETS / WATER CLOSETS TO USE NO MORE THAN 1.28 GALLONS <br /> PER FLUSH <br /> b.URINALS MAY US NO MORE THAN 0.5 GALLONS PER FLUSH <br /> c.THE MAX, FLOW RATE FOR A SHOWER HEAD IS 1.8 GALLONS PER <br /> MINUTE AT 80 PSI <br /> d.INTERIOR FAUCETS MAY NOT EXCEED SPECIFIED FLOW RATES <br /> e.RESIDENTIAL LAVATORY FAUCETS MUST NOT EXCEED 1.2 GALLONS <br /> PER MINUTE AT 20 PSI <br /> f.THE MIN. FLOW RATE OF RESIDENTIAL LAVATORY FAUCETS IS 0.8 <br /> GALLONS PER MINUTE AT 20PSI <br />15.PROVIDE SHOWERS, TUB AND TUB-SHOWER COMBINATIONS WITH <br />INDIVIDUAL CONTROL VALVES OF THE PRESSURE BALANCE OR THE <br />THERMOSTATIC MIXING VALVE TYPE INSTALLED AND ADJUSTED PER <br />MANUF. INSTRUCTIONS TO DELIVER A MAX. OF 120 DEG. F. <br />16.SHOWER STALLS SHALL BE A MINIMUM FINISHED INTERIOR OF 1,024 <br />SQUARE INCHES, BE CAPABLE OF ENCOMPASSING A 30 INCH DIAMETER <br />CIRCLE. ANY DOORS SHALL SWING OUT OF THE ENCLOSURE HAVE A <br />CLEAR OPENING OF 22 INCHES MINIMUM. SHOWER SHALL HAVE A <br />WATER DAM W/ 2 ” MIN. AND 9” MAX. ABOVE THE HIGH POINT OF THE <br />SHOWER DRAIN. THE FINISH FLOOR OF THE SHOWER SHALL HAVE A <br />MIN. ¼” AND MAX. ½” PER FT. PITCH TO DRAIN. WATERPROOF <br />MEMBRANE TO EXTEND 3 ” MIN. ABOVE THE TOP OF THE DAM AT BACK <br />AND SIDES. CONTROL VALVES LOCATED TO BE ADJUSTABLE PRIOR TO <br />ENTERING THE SHOWER. <br />17.ALL GLASS BATH AND SHOWER ENCLOSURES AND DOORS SHALL BE <br />TEMPERED AND MAINTAIN NO LESS THAN 22 ” CLEAR OPENING <br />18.FIXED PANELS OF TEMPERED GLASS SHOWER ENCLOSURES MUST <br />BE ATTACHED TO THE FRAMING W/ CLIPS, TRACKS OR CHANNELS ON AT <br />LEAST TWO SIDES. <br />19.CEMENTITIOUS TILE BRD. TO BE USED UNDER TUB AND IN SHOWER <br />ENCLOSURES UNDER SMOOTH, HARD, NON-ABSORBENT TILE TO A <br />HEIGHT OF 72 “ MIN. ABOVE DRAIN INLET. <br />20.GAS LINE SIZING SHALL BE BASED ON CPC SECTION 1216 <br />16.ATTIC FURNACE INSTALLATION SHALL COMPLY WITH MINIMUM <br />CLEARANCES PER CMC SECTION 904.2 AND ALL INSTALLATION <br />REQUIREMENTS PER CMC SECTION 904.10. <br />17.JOINTS OF DUCTWORK SHALL BE MADE AIRTIGHT BY MEANS OF <br />TAPE, MASTIC OR GASKETS. ALL JOINTS SHALL BE MECHANICALLY <br />FASTENED. ALL DUCTS SHALL BE SUPPORTED PER MANUFACTURER <br />INSTRUCTIONS. ALL DUCTS AND JOINTS SHALL BE SEALED AND <br />INSULATED TO A MIN. R4.2 <br />18.CLOSURE SYSTEMS FOR RIGID AIR DUCTS AND PLENUMS SHALL BE <br />LISTED IN ACCORDANCE WITH UL 181A, FOR FLEXIBLE AIR DUCT <br />SYSTEM, CLOSURE SYSTEMS SHALL BE LISTED UL181B. <br />19.THE LOCATION OF DUCTS INSTALLED IN CRAWL SPACES SHALL NOT <br />OBSTRUCT ACCESS TO THE ANY AREA OF THE CRAWL SPACE. WHERE <br />ACCESS IS REQUIRED UNDER DUCTS THERE MUST BE 18 ” CLEAR. <br />FACTORY MADE DUCTS SHALL BE INSTALLED 4 ” CLEAR OF EARTH. <br />20.FOR APPLIANCES WITH VENTING SYSTEMS OTHER THAN DIRECT <br />VENTING, TERMINATIONS SHALL BE NOT LESS THAN 4 ’ BELOW OR 4 ’ <br />HORIZONTALLY FROM, AND NOT LESS THAN 1 ’ ABOVE A DOOR, AN <br />OPERABLE WINDOW OR A GRAVITY AIR INLET INTO A BUILDING. THE <br />BOTTOM OF THE VENT TERMINAL SHALL BE AT LEAST 12 ” ABOVE GRADE. <br />21.PROVIDE MIN. ¾″ CONDENSATE DRAIN LINE TO APPROVED LOCATION <br />FROM COOLING EQUIPMENT OR COOLING COILS. FOR UNITS INSTALLED <br />IN ATTIC OR FURRED SPACE, PROVIDE SECONDARY DRAIN PAN AND <br />MIN. ¾″ DRAIN LINE OR PROVIDE A STANDING OVERFLOW AND <br />SEPARATE SECONDARY MIN. ¾″ DRAIN LINE FOR THE PRIMARY DRAIN <br />PAN. ROUTE THE SECONDARY DRAIN DISCHARGE TO AN APPROVED <br />LOCATION THAT CAN BE READILY OBSERVED. <br />22.PRIMARY RESIDENCE: <br />g.WATER HEATER FLUE SHALL EXTEND AT LEAST 3 ’ ABOVE THE <br />HIGHEST POINT WHERE IT PASSES THROUGH THE ROOF AND AT LEAST <br />2’ HIGHER THAN ANY PORTION OF A BUILDING WITHIN A HORIZ. <br />DISTANCE OF 10’ <br />h.SIZE, INSTALL AND BALANCE THE HVAC / HEATING SYSTEM TO <br />PROVIDE ADEQUATE AIR VOLUMES, REDUCED AIR FLOW NOISE AND <br />PROPER TEMPERATURES IN EACH ROOM <br />i.INSTALL MANUALLY ADJUSTABLE BAFFLES IN EACH SUPPLY DUCT <br />FOR FUTURE BALANCING REQUIREMENTS. <br /> <br />23.PER THE CEC, ALL NEW LOW-RISE RESIDENTIAL BUILDINGS OR <br />ADDITIONS OF 1000 SF OR GREATER ARE REQUIRED TO HAVE A WHOLE- <br />BUILDING MECHANICAL VENTILATION SYSTEM. EXHAUST-ONLY <br />VENTILATION REQUIREMENTS (ASHRAE 62.2): <br />THE FOLLOWING IS A CHECKLIST OF THE MINIMUM BEST PRACTICES <br />GUIDE FOR WHOLE-BUILDING VENTING AND LOCAL VENTILATION <br />EXHAUST. THE VENTING SOLUTIONS MUST CONFORM TO THESE <br />PRACTICES IN ORDER TO COMPLY WITH ASHRAE 62.2 <br />GENERAL REQUIREMENTS: <br />·DESIGN REQUIREMENTS SHOWN ON BUILDING DESIGN DRAWINGS <br />·COMPLIANCE WITH THE VENTILATION AIRFLOW REQUIREMENTS <br />DEMONSTRATED BY: <br />-PRESCRIPTIVE VENTILATION SYSTEM INSPECTION. VISUALLY <br />INSPECTING PRESCRIPTIVE DUCT SIZING AND FAN RATINGS <br />OR <br />-PERFORMANCE VENTILATION SYSTEM TESTING. TESTING TO <br />CONFIRM THE DELIVERY OF THE MINIMUM VENTILATION AIRFLOW <br />·COMPLETE, SIGN AND MAKE AN INSTALLATION CERTIFICATE (CF-6R- <br />MECH-05) AVAILABLE AT THE SITE <br />WHOLE-BUILDING VENTILATION: <br />·WHOLE-BUILDING EXHAUST VENTILATION SYSTEM MEETS THE <br />REQUIRED WHOLE-BUILDING VENTILATION AIRFLOW, WHICH IS CFM <br />WHOLE-BUILDING VENTILATION REQUIREMENT CALCULATIONS <br />EQUATION 4.1A (FROM ASHRAE 62.2): <br />QFAN = 0.01 X AFLOOR + 7.5 X (NBR + 1) <br />WHERE: <br />AFLOOR = CONDITIONED FLOOR AREA, FT² <br />NBR = NUMBER OF BEDROOMS; NOT TO BE LESS THAN ONE <br />QFAN = VENT. AIRFLOW REQUIREMENT = MIN. FAN AIRFLOW RATING, <br /> (CFM) <br />PLUMBING NOTES (PN): <br />GENERAL NOTES (GN): <br />9. AN APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED IN <br />DWELLING UNITS AND IN SLEEPING <br />UNITS WITHIN WHICH FUEL-BURNING APPLIANCES ARE INSTALLED AND IN <br />DWELLING UNITS THAT HAVE ATTACHED GARAGES. CARBON MONOXIDE <br />ALARM SHALL BE PROVIDED OUTSIDE OF EACH SEPARATE DWELLING UNIT <br />SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOM(S) AND ON <br />EVERY LEVEL OF A DWELLING UNIT INCLUDING BASEMENTS. (R315) <br />10. 9. 4.408.1 CONSTRUCTION WASTE MANAGEMENT. RECYCLE AND/OR <br />SALVAGE FOR REUSE A MINIMUM OF 65 PERCENT OF THE NON-HAZARDOUS <br />CONSTRUCTION AND DEMOLITION WASTE IN ACCORDANCE WITH EITHER <br />SECTION 4.408.2, 4.408.3 OR 4.408.4, OR MEET A MORE STRINGENT LOCAL <br />CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT ORDINANCE. <br />REV DATE REMARKS