Laserfiche WebLink
EXISTING HOUSE <br />W RAYMAR ST. <br />(E) DRIVEWAY <br />(E) CONCRETE PAD <br />APN: 01002423 <br />NO: 1517 <br />WATER <br />METER <br />4" / 1'-0" <br />4" / 1'-0"4" / 1'-0" <br />4" / 1'-0"4" / 1'-0" <br />4" <br /> <br />/ <br /> <br />1 <br />' <br />- <br />0 <br />" <br />4" <br /> <br />/ <br /> <br />1 <br />' <br />- <br />0 <br />" <br />4" / 1'-0"4" / 1'-0" <br />LAWN <br />(E) GATE <br />(E) GATE <br />(E) ELECTRICAL PANEL <br />(E) GAS METER <br />(E) STORAGE <br />4" <br /> <br />/ <br /> <br />1 <br />' <br />- <br />0 <br />" <br />4" <br /> <br />/ <br /> <br />1 <br />' <br />- <br />0 <br />" <br />4" / 1'-0" <br />4" / 1'-0" <br />(E) <br />BLOCK <br />FENCE <br />(E) <br />BLOCK <br />FENCE <br />(E) BLOCK FENCE <br />(E) GATE <br />P.L. 60.40 ' <br />P. <br />L <br />. <br /> <br />10 <br />2 <br />' <br />P. <br />L <br />. <br /> <br />10 <br />2 <br />' <br />P.L. 60.40 ' <br />REPLACE SHINGLE ROOFING, <br />SEE SPEC. ON SHEET A1.0 <br />ASPHALT SHINGLE <br />CLASS A ESR 1475 <br />TWO LAYERS OF UNDERLAYMENT <br />INSTALLED PER CRC TBL. R905.1.1(2) <br />NEW (2) LAYERS OF 15# FELT LAID WITH 19" OVERLAP OF WATERPROOFING UNDERLAYMENT <br />FIRST AND SUCCEEDING <br />COURSES OF UNDERLAY TO <br />BE 36" WIDE AND LAPPED 19"2-PLY UNDERLAYMENT <br />TYPE 15 FELT <br />SEALING STRIP APPROVED SELF-SEALING SHINGLES <br />OR INTERLOCKING SHINGLES <br />18" <br />36"17" <br />19" <br />DATE: <br />P.M.: <br />DRAWN BY: <br />JOB NO.: <br />26081 Merit Cir, STE 111 <br />Laguna Hills, CA 92653 <br />909-257-7040 WWW.BNDESIGNBUILDINC.COM <br />THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN <br />DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK <br />EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. <br />D ES I GNBUILDCNI <br />6/ <br />1 <br />2 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />7 <br />: <br />0 <br />6 <br />: <br />5 <br />1 <br /> <br />P <br />M <br />A1.0 <br />B.N. <br />F.M. <br />SITE PLAN <br />06.10.2025 <br />202500149 <br />1517 W RAYMAR <br />ST, SANTA ANA, <br />CA 92703 <br />SINGLE <br />FAMILY HOME <br />SITE KEYNOTES <br />1 EXISTING CONCRETE PAD <br />2 WATER METER <br />3 EXISTING ELECTRICAL PANEL <br />4 PROPERTY LINE <br />5 EXISTING BLOCK FENCE <br />6 EXISTING DRIVEWAY <br />7 EXISTING GATE <br />8 EXISTING GAS METER <br />0 2'-8"5'-4"10'-8" <br />SCALE: 3/16" = 1'-0" <br />REV DATE REMARKS <br />SITE GENERAL NOTES <br />1. PLEASE CLEARLY INDICATE ON PLAN ALL OF THE MATERIALS, SYSTEMS, COMPONENTS AND <br />WORK REQUIRED TO HAVE SPECIAL INSPECTION. <br />2. SPECIFY TYPE AND EXTENT OF EACH SPECIAL INSPECTION AND TESTING THAT IS <br />APPLICABLE TO THE PROJECT. FOR EACH TYPE OF SPECIAL INSPECTION, PLEASE ITEMIZE <br />THE INSPECTION TASKS AND IDENTIFY WHETHER IT WILL BE CONTINUOUS OR PERIODIC <br />SPECIAL INSPECTION. <br />3. SPECIFY ADDITIONAL SPECIAL INSPECTION REQUIREMENTS IF REQUIRED PER SECTION <br />1705.10 AND 1705.11 <br />4. FASTENERS FOR WOOD SHINGLES SHALL BE CORROSION RESISTANT WITH A MINIMUM <br />PENETRATION OF 3/4 INCH (19.1 MM) INTO THE SHEATHING. FOR SHEATHING LESS THAN 1/2 <br />INCH (12.7 MM) IN THICKNESS, THE FASTENERS SHALL EXTEND THROUGH THE SHEATHING. <br />EACH SHINGLE SHALL BE ATTACHED WITH A MINIMUM OF TWO FASTENERS.THE FASTENERS <br />FOR THE ROOFING SHALL BE CORROSION RESISTANT PER CRC R905.2.5. <br />5. ALL EXTERIOR DIMENSIONS ARE FROM FACE OF FINISH. <br />6. CONTRACTORS TO VERIFY ALL (E) DIMENSIONS AND CONDITIONS PRIOR TO <br />CONSTRUCTION. <br />7. CARE SHALL BE TAKEN TO ELIMINATE DAMAGE TO (E) MATERIALS AND SURFACES DURING <br />CONSTRUCTION. ANY DAMAGES TO EXISTING CONSTRUCTION SHALL BE REPLACED OR <br />REPAIRED AT NO ADDITIONAL COST. <br />8. INSULATION SHALL BE PROTECTED FROM DAMAGE, INCLUDING THAT DUE TO SUNLIGHT, <br />MOISTURE, EQUIPMENT MAINTENANCE & WIND. CELLULAR FOAL INSULATION SHALL BE <br />PROTECTED AS ABOVE OR PAINTED WITH A COATING THAT IS WATER RETARDANT & <br />PROVIDES SHIELDING FROM SOLAR RADIATION THAT CAN CAUSE DEGRADATION OF THE <br />MATERIAL. <br /> 3/16" = 1'-0"1 SITE PLAN <br />RE <br />F <br />. <br /> <br />N <br />O <br />R <br />T <br />H <br />1 <br />2 <br />3 <br />4 <br />5 <br />5 <br />5 <br />6 <br />6 <br />7 <br />7 <br />7 <br />8 <br /> 12" = 1'-0"2 UNDERLAYMENT