Laserfiche WebLink
1' <br />- <br />6 <br />" <br />3' <br />- <br />8 <br />" <br />4' <br />- <br />0 <br />" <br />5' <br />- <br />0 <br />" <br />6' <br />- <br />6 <br />" <br />MI <br />N <br />. <br /> <br />7 <br />' <br /> <br />- <br />6 <br />" <br />FINISHED FLOOR <br />OUTLETS ABOVE THE FLOOR <br />LIGHT SWITCHES <br />OUTLETS ABOVE THE <br />COUNTERTOP <br />THERMOSTAT <br />ELECTRICAL PANEL <br />TO BE MOUNTED AT <br />HIGHEST POINT IN ROOMSD <br />SYMBOLS <br /> <br /> <br />SINGLE POLE SWITCH SCONCE FIXTURE: UP LIT - LED <br />D= DIMMER <br />V = MANUAL ON, AUTO OFF SCONCE: UP AND DOWN LIT - LED <br />WP = WATER PROOF <br />T = TIMER SWITCH <br />THREE-WAY DIMMER SWITCH FLUORESCENT FIXTURE <br /> <br />SINGLE OUTLET EXHAUST FAN w/100 CFM MIN. <br /> FAN w/100 CFM MIN. <br />EXTERIOR LIGHT V = W/ MANUAL ON, AUTO OFF <br /> H = W/ AUTO ON HUMIDISTAT SENSOR <br />DUPLEX OUTLET EXHAUST FAN w/50 CFM MIN. <br />WP = WATER PROOF V = MANUAL ON, AUTO OFF <br />GFCI = GROUND FAULT CIRCUIT INTER. H = W/ AUTO ON HUMIDISTAT SENSOR <br />AFCI = ARC FAULT CIRCUIT INTER. <br />USB <br />QUADROPOLE OUTLET SURFACE MOUNTED FIXTURES <br /> M = MOTION SENSOR <br /> P = MOTION SENSOR W/ PHOTO SENSE <br /> E = HIGH EFFICIENCY <br />WALL MOUNTED LAMP LV = LOW VOLTAGE <br />MOTION SENSOR/PHOTOCELL. <br /> SPEAKER <br />220V OUTLET RECESSED FIXTURE-LED <br />R = RANGE OUTLET <br />D = CLOTHES DRYER OUTLET <br />H = RADIANT HEATER H3 WALL MOUNTED FIXTURE - LED <br /> <br />SPECIAL-PURPOSE OUTLET HOME SECURITY PANEL <br />DW = DISHWASHER OUTLET <br />GD = GARBAGE DISPOSAL <br />S = STEAM SHOWER SMOKE DETECTOR <br /> CARBON MONOXIDE DETECTOR <br /> <br />CLOCK OUTLET SMOKE & CARBON MONOXIDE DETECTOR <br /> <br />EXIT LIGHT OUTLET HOSE BIB <br />DATA OUTLET 1.SWITCHES TO BE 42" ABV. FF UON <br />T = TELEPHONE 2. OUTLETS TO BE 15" ABV. FF UON <br />TV = TELEVISION 3. OUTLETS ABV. COUNTER TOPS TO BE <br />EN = ETHERNET 42" ADV. FF UON <br />M = MULTI (TELE./TV/EN) <br />J BOX COVE LIGHTING <br />CAMERA DIFFUSER <br />RECESSED LINEAR LIGHT VACANCY SENSOR <br />CL <br />. <br />C <br />SD <br />S <br />HB <br />3D <br />W <br />PP <br />- <br />S <br />S/C <br />R <br />(E) GARAGE <br />(E) MASTER BEDROOM <br />N.I.C <br />(E) <br />BATH <br />(E) <br />KITCHEN <br />(E) BEDROOM #2 <br />(E) CL. <br />(E) BEDROOM #1 <br />(E) BEDROOM #3 <br />N.I.C <br />N.I.C N.I.C <br />N.I.C <br />REF. <br />ENTRY <br />SD SD <br />SD <br />SINK <br />(E) CL. <br />(E) CL. <br />(E) BATH <br />(E) BATH <br />(E) ATTIC <br />ACCESS <br />(E) <br />LINEN <br />(E) <br />ELECTRICAL <br />PANEL <br />(E) ATTIC <br />ACCESS <br />NOTE : <br />-COMBINATION SMOKE & CO ALARMS <br />SMOKE ALARM SHALL BE INTERCONNECTED <br />HARDWIRED WITH BATTERY BACKUP AND <br />SHALL BE INSTALLED IN ACCORDANCE WITH NFPA <br />72. CARBON MONOXIDE ALARM BE <br />INTERCONNECTED HARWARD WITH BATTERY <br />BACKUP. <br />-SMOKE ALARM SHALL BE INSTALLED NOT LESS <br />THAN 3FT HORIZONTALLY FROM THE DOOR OF THE <br />BATHROOM PER 2022 CRC, SECTION R314.3. <br />-SMOKE ALARMS SHALL BE INSTALLED A MINIMUM <br />OF 20FT HORIZONTAL DISTANCE FROM A <br />PERMANENTLY INSTALLED COOKING APPLIANCE OR <br />PLEASE SHOW THAT IONIZATION OR <br />PHOTOELECTRIC SMOKE ALARMS SHALL BE <br />PROVIDED IN ACCORDANCE WITH 2022 CRC, <br />SECTION R314.3.3 ITEM 4 EXCEPTION. <br />(E) GAS METER <br />(E) STORAGE <br />(E) GATE <br />(E) GATE <br />(E) DRIVEWAY <br />(E) CONCRETE PAD <br />P. <br />L <br />. <br /> <br />10 <br />2 <br />' <br />P. <br />L <br />. <br /> <br />10 <br />2 <br />' <br />(N) ISLAND <br />(N) WALK IN CLOSET <br />(N) BATH <br />(E) <br />TANK <br />W.H. <br />(E) LIVING ROOM <br />S/C <br />P.L. 60.40 ' <br />GFCI <br />GFCI <br />GF <br />C <br />I <br />GF <br />C <br />I <br />GF <br />C <br />I <br />GF <br />C <br />I <br />GF <br />C <br />I <br />GF <br />C <br />I <br />GFCI <br />GFCI <br />GFCI <br />AF <br />C <br />I <br />KITCHEN <br />HOOD <br />GARBAGE <br />DISPOSAL <br />20A <br />+32" <br />+72" <br />+15" <br />20 AMP SMALL <br />APPLIANCE <br />GF <br />C <br />I +15" <br />+42" <br />+42" <br />20A <br />+42"+32" <br />+42" <br />+42" <br />+42" <br />+42" <br />N.I.C <br />VACANCY <br />SENSOR <br />VACANCY <br />SENSOR <br />VACANCY <br />SENSOR <br />3' <br />- <br />0 <br />" <br />3'-0" <br />3'-0" <br />3' <br />- <br />0 <br />" <br />3'-0" <br />EQEQ <br />WP <br />WP <br />WP <br />FAN <br />FAN <br />FAN <br />FAN <br />3D <br />3D <br />3D <br />NOTE : <br /> SCREENS OR OTHER DEVICES THAT OBSTRUCT <br />THE FLOW OF THE EXHAUST DUCT SHALL NOT BE <br />USED AT CLOTHES DRYER EXHAUST DUCTS IN <br />ACCORDANCE WITH 2022 CMC, SECTION 504.4 <br />NOTE: <br />ADD DOUBLE PROTECTION <br />OUTLET AFCI AND GFCI PER <br />SECTION 210.8A 910 AND <br />210.12 OF CEC 2022 FOR <br />LAUNDRY AND KITCHEN AREA. <br />NOTE : <br />PLUMBING INSPECTOR TO VERIFY IF GRIT TRAP <br />FROM PERFORATED PIPE REQUIRED PRIOR TO <br />SS TIE IN. <br />LICENSE PLUMBER TO INCREASE GAS LINE IF <br />REQUIRE VERIFIED FIELD CONDITIONS, BENDS, <br />LENGTH... IN FIELD <br />NOTE : <br />EVERY KITCHEN SHALL HAVE HOOD TO THE <br />OUTSIDE OF THE BUILDING W/ MIN. LESS <br />THAN 750 SF REQUIRES 85% CE OR 280 CFM . <br />6” DIAM. EQUIPPED WITH BACKDRAFT <br />DAMPER, THAT HAS A MAXIMUM SOUND <br />RATING OF 3-SONES AND THE REQUIREMENT <br />FOR HERS VERIFICATION. <br />NOTE : <br />WATER PIPING SHALL MEET THE INSULATION <br />REQUIREMENTS OF 2022 CALIFORNIA ENERGY <br />CODE, SECTION 150.0(J)2.A. <br />ALL DOMESTIC HOT WATER PIPING SHALL BE <br />INSULATED AS SPECIFIED IN SECTION 609.11 OF <br />THE CALIFORNIA PLUMBING CODE. IN ADDITION, <br />THE FOLLOWING PIPING CONDITIONS SHALL HAVE <br />A MINIMUM INSULATION WALL THICKNESS OF 1 <br />INCH OR A MINIMUM INSULATION R-VALUE OF 7.7: <br />I. THE FIRST 5 FEET (1.5 METERS) OF COLD <br />WATER PIPES FROM THE STORAGE TANK. <br />II. ALL HOT WATER PIPING WITH A NOMINAL <br />DIAMETER EQUAL TO OR GREATER THAN 3/4 INCH <br />(19 MILLIMETER) AND LESS THAN 1 INCH. <br />III. ALL HOT WATER PIPING WITH A NOMINAL <br />DIAMETER LESS THAN 3/4 INCH THAT IS: <br />A. ASSOCIATED WITH A DOMESTIC HOT WATER <br />RECIRCULATION SYSTEM; <br />B. FROM THE HEATING SOURCE TO THE KITCHEN <br />FIXTURES; <br />C. FROM THE HEATING SOURCE TO A STORAGE <br />TANK OR BETWEEN STORAGE TANKS; OR <br />D. BURIED BELOW GRADE. <br />DELTA BREEZSLIM <br />70 CFM WITH HUMIDITY SENSOR <br />CFM EXHAUST BATH FAN, WHITE <br />NOTE : <br />LUMINAIRES TO BE CONTROLLED <br />BY EITHER DIMMERS OR <br />VACANCY SENSORS IN DINING <br />ROOM AND LIVING ROOM. <br />DELTA BREEZSLIM <br />70 CFM WITH HUMIDITY SENSOR <br />CFM EXHAUST BATH FAN, WHITE <br />DELTA BREEZSLIM <br />70 CFM WITH HUMIDITY SENSOR <br />CFM EXHAUST BATH FAN, WHITE <br />EQ <br />EQ <br />DATE: <br />P.M.: <br />DRAWN BY: <br />JOB NO.: <br />26081 Merit Cir, STE 111 <br />Laguna Hills, CA 92653 <br />909-257-7040 WWW.BNDESIGNBUILDINC.COM <br />THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN <br />DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK <br />EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. <br />D ES I GNBUILDCNI <br />6/ <br />1 <br />2 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />7 <br />: <br />0 <br />6 <br />: <br />5 <br />9 <br /> <br />P <br />M <br />A2.2 <br />B.N. <br />S.R. <br />ELECTRICAL <br />PLAN <br />06.10.2025 <br />202500149 <br />1517 W RAYMAR <br />ST, SANTA ANA, <br />CA 92703 <br />SINGLE <br />FAMILY HOME <br />REV DATE REMARKS <br />1. FRIDGE (20 AMP) <br />2. COOKTOP/RANGE (20 AMP, 120/240V) <br />3. RANGE HOOD (15-20 AMP) <br />4. COUNTERTOP RECEPTACLES <br />(2 CIRCUITS, 20 AMP) <br />5. KITCHEN LIGHTING (15-20 AMP) <br />6. EACH ROOM/HALLWAY SHALL HAVE SEPARATE CIRCUITS FOR LIGHTS AND <br />RECEPTACLES <br />(20 AMP) <br />7. WALL MOUNTED AIR CONDITIONERS <br />(20 AMP EACH) <br />8. BATHROOM RECEPTACLES AND LIGHTS <br />(20 AMP) <br />9. BATHROOM FAN (20 AMP) <br />10. DINING ROOM: SEPARATE (20 AMP) CIRCUIT FOR ENTERTAINMENT <br />CENTER <br />ELECTRICAL SYSTEM TO BE INSTALLED ELECTRICAL SYSTEM TO BE INSTALLED <br />WITH SEPARATE CIRCUITS FOR:WITH SEPARATE CIRCUITS FOR: <br />GENERAL ELECTRICAL NOTES: <br />1. THE PROJECT CONTACT AND/OR THEIR LICENSED CONTRACTOR SHALL CONFIRM THE LOCATION, <br />SIZE AND CAPACITY OF THE EXISTING ELECTRICAL SERVICE ON THE PROPERTY. THE PROPOSED <br />SERVICE CONNECTIONS FOR THE UNIT SHALL BE VERIFIED AND DETERMINED TO BE VIABLE <br />CONNECTION PATHS PRIOR TO COMMENCING WORK ON THE PROJECT. IF THE UTILITY LINE OR <br />CONNECTION IS MISSING, DISPLACED OR OTHERWISE INACCURATE, THE CONTRACTOR AND/OR <br />PROJECT CONTACT SHALL NOTIFY ALL PARTIES AND A REVISION TO THE PLANS SHALL BE MADE. <br />2. THE PROJECT CONTACT AND/OR THEIR LICENSED CONTRACTOR SHALL CONFIRM THE PROPOSED <br />UNIT ELECTRICAL SERVICE LINE'S CAPACITY TO SERVE ALL APPLIANCES AND ELECTRICAL FIXTURES <br />IN THE UNIT. IF THE PROPOSED ELECTRICAL CONNECTION LINE TO THE UNIT AND INSIDE THE UNIT <br />ARE MISSING, DISPLACED, INCORRECT CAPACITY OR OTHERWISE INNACURATE, THE CONTRACTOR <br />AND/OR PROJECT CONTACT SHALL NOTIFY ALL PARTIES AND A REVISION TO THE PLANS SHALL BE <br />MADE. <br />3. SUBFEED FROM EXISTING MAIN SERVICE TO PROPERTY: CONTRACTOR TO VERIFY AVAILABLE <br />CAPACITY FOR ADDITIONAL LOAD (FOR UNIT). <br />4. ELECTRICAL PANELBOARD SCHEDULE, CIRCUITS, WIRING DIAGRAM, POWER PLAN PERFORMED BY <br />LICENSED ELECTRICTIAN DURING CONSTRUCTION IN ACCORDANCE TO 2022 CALIFORNIA ELECTRICAL <br />CODE. <br />5. ELECTRICAL PANEL GROUNDING ACCORDING TO 2022 CALIFORNIA ELECTRICAL CODE. <br />6. ALL APPLIANCES AND ELECTRICAL FIXTURES SHALL BE INSTALLED IN ACCORDANCE WITH <br />MANUFACTURER'S RECOMMENDATIONS AND 2022 CALIFORNIA ELECTRICAL CODE. <br />7. UNLESS SPECIFIED IN THE SCHEDULE, AN APPLIANCE'S BRAND AND MODEL TBD DURING <br />CONSTRUCTION, PROVIDED IT MEETS 2022 CALIFORNIA ELECTRICAL CODE. <br />8. DURING CONSTRUCTION AND INSTALLATION OF THE ELECTRICAL SYSTEM ANY APPLIANCES LISTED <br />MAY BE REPLACED WITH AN EQUIVALENT MODEL AND BRAND PROVIDED THEY MEET 2022 <br />CALIFORNIA ELECTRICAL CODE AND MEET OR EXCEED ALL APPLICABLE ENERGY STANDARDS IN THE <br />TITLE 24 REPORT FOR THE PROJECT. <br />9. ANNULAR SPACES AROUND ELECTRIC CABLES, CONDUITS OR OTHER OPENINGS IN PLATES AT <br />EXTERIOR WALLS, FOUNDATION, FLOOR OR ROOFTOP SHALL BE PROTECTED AGAINST THE PASSAGE <br />OF RODENTS BY CLOSING SUCH OPENINGS WITH CEMENT MORTAR, CONCRETE MASONRY OR <br />SIMILAR METHOD ACCEPTABLE TO THE ENFORCING AGENCY. <br />1. BATHROOM REQUIRES A DEDICATED 20-AMP CIRCUIT FOR THE REQUIRED BATHROOM OUTLETS. <br />THIS CIRCUIT CANNOT SUPPLY ANY OTHER RECEPTACLES, LIGHTS, FANS, ETC.. (EXCEPTION: WHERE <br />THE CIRCUIT SUPPLIES A SINGLE BATHROOM, OUTLETS FOR OTHER EQUIPMENT WITHIN THE SAME <br />BATHROOM SHALL BE PERMITTED TO BE SUPPLIED. ) <br />2. ALL 120-VOLT, SINGLE PHASE, 15- AND 20- AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS <br />INSTALLED IN DWELLING UNIT KITCHEN, DINING ROOMS, LIVING ROOMS, BEDROOMS, CLOSETS, <br />HALLWAYS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC-FAULT CIRCUIT <br />INTERRUPTER, COMBINATION TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT. <br />CEC 210.12 <br />1. PROVIDE TAMPER RESISTANT RECEPTACLES, ARCH-FAULT AND GFCI AS REQUIRED BY <br />APPLICABLE CODES. <br />2. PROVIDE AFCI PROTECTION FOR ALL OUTLETS OR DEVICES IN A READILY ACCESSIBLE LOCATION <br />IN KITCHENS, FAMILY ROOMS, DINING, LIVING ROOMS, LIBRARIES DENS, LAUNDRY, OR SIMILAR <br />ROOMS AND AREAS. <br />3. TAMPER-RESISTANT RECEPTACLES ARE REQUIRED FOR RECEPTACLES THAT ARE 66" AND LESS <br />ABOVE THE FINISHED FLOOR, AND IN ANY OF THE FOLLOWING LOCATIONS: KITCHENS, FAMILY <br />ROOMS, DINING, LIVING ROOM, LIBRARIES DENS, BEDROOMS, RECREATION ROOMS, LAUNDRY, OR <br />SIMILAR ROOMS OR WALL SPACE. RECEPTACLES IN A DEDICATED SPACE FOR A REFRIGERATOR, <br />DISHWASHER, OR WASHER/DRYER ARE EXEMPT. <br />BRANCH CIRCUIT NOTES:BRANCH CIRCUIT NOTES: <br />RECEPTACLE NOTES:RECEPTACLE NOTES: <br />1. ALL EXTERIOR LUMINARIES TO BE HIGH EFFICACY AND SHALL MEET THE FOLLOWING <br />REQUIREMENTS, AS APPLICABLE PER CEC 150.0(K)(3): <br />A. CONTROLLED BY A MANUAL ON AND OFF SWITCH THAT DOES NOT OVERRIDE TO ON THE <br />AUTOMATIC <br />ACTIONS OF ITEMS B) OR C) BELOW; AND <br />B. CONTROLLED BY PHOTOCELL AND MOTION SENSOR. CONTROLS THAT OVERRIDE TO ON SHALL <br />NOT BE <br />ALLOWED UNLESS THE OVERRIDE AUTOMATICALLY REACTIVATES THE MOTION SENSOR WITHIN 6 <br />HOURS; OR <br />C. CONTROLLED BY ONE OF THE FOLLOWING METHODS: <br />A. (1) PHOTOCONTROL AND AUTOMATIC TIME SWITCH CONTROL. <br />B. (2) ASTRONOMICAL TIME CLOCK. <br />C. (3) ENERGY MANAGEMENT CONTROL SYSTEM. <br />1. ALL RECESSED LUMINAIRES IN CEILINGS SHALL COMPLY WITH ALL OF THE FOLLOWING: <br />A. BE LISTED FOR 'ZERO CLEARANCE INSULATION CONTACT (IC)' BY UL (UNDERWRITERS <br />LABORATORIES) OR OTHER NATIONALLY RECOGNIZED TESTING/RATING LABORATORIES; <br />B. HAVE A LABEL THAT THE LUMINAIRE IS AIRTIGHT; <br />C. BE SEALED WITH A GASKET OR CAULK BETWEEN THE LUMINAIRE HOUSING AND CEILING, AND <br />SHALL HAVE ALL AIR LEAK PATHS BETWEEN CONDITIONED AND UNCONDITIONED SPACES SEALED <br />WITH A GASKET OR CAULK; <br />D. SHALL NOT CONTAIN SCREW BASE SOCKETS; <br />E. SHALL ONLY CONTAIN “HIGH EFFICACY” LIGHT SOURCES OR BE MARKED AS 'JA8-2022-E' <br />EXTERIOR LUMINAIRES:EXTERIOR LUMINAIRES: <br />RECESSED DOWNLIGHT LUMINAIRES IN CEILINGS (T24):RECESSED DOWNLIGHT LUMINAIRES IN CEILINGS (T24): <br />1. ALL LIGHTING SHALL BE HIGH EFFICACY. LAMPS DEEMED AUTOMATICALLY HIGH <br />EFFICACY NEED ONLY MANUAL ON/OFF SWITCH. IF THE LAMP IS NOT AUTOMATICALLY <br />HIGH EFFICACY, IT MUST BE JA8 CERTIFIED AND IS REQUIRED TO HAVE A MANUAL <br />ON/OFF SWITCH PLUS EITHER A VACANCY SENSOR OR DIMMER CONTROL. <br />2. IN BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS, AT LEAST ONE <br />LUMINAIRE IN EACH OF THESE SPACES SHALL BE CONTROLLED BY A VACANCY <br />SENSOR. VACANCY SENSORS SHALL BE INSTALLED IN ALL OF THE ROOM TYPES <br />LISTED, IF APPLICABLE TO THE PROJECT. <br />3. ALL LIGHT MOUNTING ACCESSORIES SHALL BE PROVIDED ACCORDING TO LIGHTING <br />FIXTURE'S MANUFACTURER'S REQUIREMENTS. <br />4. IF NOT SPECIFIED IN THE SCHEDULE - LIGHT'S BRAND AND MODEL TBD DURING <br />CONSTRUCTION, PROVIDED IT MEETS 2022 CALIFORNIA ELECTRICAL CODE. <br />5. DURING CONSTRUCTION AND INSTALLATION OF THE ELECTRICAL SYSTEM ANY LIGHTS <br />LISTED CAN BE REPLACED WITH EQUIVALENT BRAND/MODEL PROVIDED THEY MEET 2022 <br />CALIFORNIA ELECTRICAL CODE. <br />LIGHTING NOTES:LIGHTING NOTES: <br /> 1/4" = 1'-0"1 ELECTRICAL PLAN <br />RE <br />F <br />. <br /> <br />N <br />O <br />R <br />T <br />H