<br />FINISHED FLOOR
<br />OUTLETS ABOVE THE FLOOR
<br />LIGHT SWITCHES
<br />OUTLETS ABOVE THE
<br />COUNTERTOP
<br />THERMOSTAT
<br />ELECTRICAL PANEL
<br />TO BE MOUNTED AT
<br />HIGHEST POINT IN ROOMSD
<br />SYMBOLS
<br />
<br />
<br />SINGLE POLE SWITCH SCONCE FIXTURE: UP LIT - LED
<br />D= DIMMER
<br />V = MANUAL ON, AUTO OFF SCONCE: UP AND DOWN LIT - LED
<br />WP = WATER PROOF
<br />T = TIMER SWITCH
<br />THREE-WAY DIMMER SWITCH FLUORESCENT FIXTURE
<br />
<br />SINGLE OUTLET EXHAUST FAN w/100 CFM MIN.
<br /> FAN w/100 CFM MIN.
<br />EXTERIOR LIGHT V = W/ MANUAL ON, AUTO OFF
<br /> H = W/ AUTO ON HUMIDISTAT SENSOR
<br />DUPLEX OUTLET EXHAUST FAN w/50 CFM MIN.
<br />WP = WATER PROOF V = MANUAL ON, AUTO OFF
<br />GFCI = GROUND FAULT CIRCUIT INTER. H = W/ AUTO ON HUMIDISTAT SENSOR
<br />AFCI = ARC FAULT CIRCUIT INTER.
<br />USB
<br />QUADROPOLE OUTLET SURFACE MOUNTED FIXTURES
<br /> M = MOTION SENSOR
<br /> P = MOTION SENSOR W/ PHOTO SENSE
<br /> E = HIGH EFFICIENCY
<br />WALL MOUNTED LAMP LV = LOW VOLTAGE
<br />MOTION SENSOR/PHOTOCELL.
<br /> SPEAKER
<br />220V OUTLET RECESSED FIXTURE-LED
<br />R = RANGE OUTLET
<br />D = CLOTHES DRYER OUTLET
<br />H = RADIANT HEATER H3 WALL MOUNTED FIXTURE - LED
<br />
<br />SPECIAL-PURPOSE OUTLET HOME SECURITY PANEL
<br />DW = DISHWASHER OUTLET
<br />GD = GARBAGE DISPOSAL
<br />S = STEAM SHOWER SMOKE DETECTOR
<br /> CARBON MONOXIDE DETECTOR
<br />
<br />CLOCK OUTLET SMOKE & CARBON MONOXIDE DETECTOR
<br />
<br />EXIT LIGHT OUTLET HOSE BIB
<br />DATA OUTLET 1.SWITCHES TO BE 42" ABV. FF UON
<br />T = TELEPHONE 2. OUTLETS TO BE 15" ABV. FF UON
<br />TV = TELEVISION 3. OUTLETS ABV. COUNTER TOPS TO BE
<br />EN = ETHERNET 42" ADV. FF UON
<br />M = MULTI (TELE./TV/EN)
<br />J BOX COVE LIGHTING
<br />CAMERA DIFFUSER
<br />RECESSED LINEAR LIGHT VACANCY SENSOR
<br />CL
<br />.
<br />C
<br />SD
<br />S
<br />HB
<br />3D
<br />W
<br />PP
<br />-
<br />S
<br />S/C
<br />R
<br />(E) GARAGE
<br />(E) MASTER BEDROOM
<br />N.I.C
<br />(E)
<br />BATH
<br />(E)
<br />KITCHEN
<br />(E) BEDROOM #2
<br />(E) CL.
<br />(E) BEDROOM #1
<br />(E) BEDROOM #3
<br />N.I.C
<br />N.I.C N.I.C
<br />N.I.C
<br />REF.
<br />ENTRY
<br />SD SD
<br />SD
<br />SINK
<br />(E) CL.
<br />(E) CL.
<br />(E) BATH
<br />(E) BATH
<br />(E) ATTIC
<br />ACCESS
<br />(E)
<br />LINEN
<br />(E)
<br />ELECTRICAL
<br />PANEL
<br />(E) ATTIC
<br />ACCESS
<br />NOTE :
<br />-COMBINATION SMOKE & CO ALARMS
<br />SMOKE ALARM SHALL BE INTERCONNECTED
<br />HARDWIRED WITH BATTERY BACKUP AND
<br />SHALL BE INSTALLED IN ACCORDANCE WITH NFPA
<br />72. CARBON MONOXIDE ALARM BE
<br />INTERCONNECTED HARWARD WITH BATTERY
<br />BACKUP.
<br />-SMOKE ALARM SHALL BE INSTALLED NOT LESS
<br />THAN 3FT HORIZONTALLY FROM THE DOOR OF THE
<br />BATHROOM PER 2022 CRC, SECTION R314.3.
<br />-SMOKE ALARMS SHALL BE INSTALLED A MINIMUM
<br />OF 20FT HORIZONTAL DISTANCE FROM A
<br />PERMANENTLY INSTALLED COOKING APPLIANCE OR
<br />PLEASE SHOW THAT IONIZATION OR
<br />PHOTOELECTRIC SMOKE ALARMS SHALL BE
<br />PROVIDED IN ACCORDANCE WITH 2022 CRC,
<br />SECTION R314.3.3 ITEM 4 EXCEPTION.
<br />(E) GAS METER
<br />(E) STORAGE
<br />(E) GATE
<br />(E) GATE
<br />(E) DRIVEWAY
<br />(E) CONCRETE PAD
<br />P.
<br />L
<br />.
<br />
<br />10
<br />2
<br />'
<br />P.
<br />L
<br />.
<br />
<br />10
<br />2
<br />'
<br />(N) ISLAND
<br />(N) WALK IN CLOSET
<br />(N) BATH
<br />(E)
<br />TANK
<br />W.H.
<br />(E) LIVING ROOM
<br />S/C
<br />P.L. 60.40 '
<br />GFCI
<br />GFCI
<br />GF
<br />C
<br />I
<br />GF
<br />C
<br />I
<br />GF
<br />C
<br />I
<br />GF
<br />C
<br />I
<br />GF
<br />C
<br />I
<br />GF
<br />C
<br />I
<br />GFCI
<br />GFCI
<br />GFCI
<br />AF
<br />C
<br />I
<br />KITCHEN
<br />HOOD
<br />GARBAGE
<br />DISPOSAL
<br />20A
<br />+32"
<br />+72"
<br />+15"
<br />20 AMP SMALL
<br />APPLIANCE
<br />GF
<br />C
<br />I +15"
<br />+42"
<br />+42"
<br />20A
<br />+42"+32"
<br />+42"
<br />+42"
<br />+42"
<br />+42"
<br />N.I.C
<br />VACANCY
<br />SENSOR
<br />VACANCY
<br />SENSOR
<br />VACANCY
<br />SENSOR
<br />3'
<br />-
<br />0
<br />"
<br />3'-0"
<br />3'-0"
<br />3'
<br />-
<br />0
<br />"
<br />3'-0"
<br />EQEQ
<br />WP
<br />WP
<br />WP
<br />FAN
<br />FAN
<br />FAN
<br />FAN
<br />3D
<br />3D
<br />3D
<br />NOTE :
<br /> SCREENS OR OTHER DEVICES THAT OBSTRUCT
<br />THE FLOW OF THE EXHAUST DUCT SHALL NOT BE
<br />USED AT CLOTHES DRYER EXHAUST DUCTS IN
<br />ACCORDANCE WITH 2022 CMC, SECTION 504.4
<br />NOTE:
<br />ADD DOUBLE PROTECTION
<br />OUTLET AFCI AND GFCI PER
<br />SECTION 210.8A 910 AND
<br />210.12 OF CEC 2022 FOR
<br />LAUNDRY AND KITCHEN AREA.
<br />NOTE :
<br />PLUMBING INSPECTOR TO VERIFY IF GRIT TRAP
<br />FROM PERFORATED PIPE REQUIRED PRIOR TO
<br />SS TIE IN.
<br />LICENSE PLUMBER TO INCREASE GAS LINE IF
<br />REQUIRE VERIFIED FIELD CONDITIONS, BENDS,
<br />LENGTH... IN FIELD
<br />NOTE :
<br />EVERY KITCHEN SHALL HAVE HOOD TO THE
<br />OUTSIDE OF THE BUILDING W/ MIN. LESS
<br />THAN 750 SF REQUIRES 85% CE OR 280 CFM .
<br />6” DIAM. EQUIPPED WITH BACKDRAFT
<br />DAMPER, THAT HAS A MAXIMUM SOUND
<br />RATING OF 3-SONES AND THE REQUIREMENT
<br />FOR HERS VERIFICATION.
<br />NOTE :
<br />WATER PIPING SHALL MEET THE INSULATION
<br />REQUIREMENTS OF 2022 CALIFORNIA ENERGY
<br />CODE, SECTION 150.0(J)2.A.
<br />ALL DOMESTIC HOT WATER PIPING SHALL BE
<br />INSULATED AS SPECIFIED IN SECTION 609.11 OF
<br />THE CALIFORNIA PLUMBING CODE. IN ADDITION,
<br />THE FOLLOWING PIPING CONDITIONS SHALL HAVE
<br />A MINIMUM INSULATION WALL THICKNESS OF 1
<br />INCH OR A MINIMUM INSULATION R-VALUE OF 7.7:
<br />I. THE FIRST 5 FEET (1.5 METERS) OF COLD
<br />WATER PIPES FROM THE STORAGE TANK.
<br />II. ALL HOT WATER PIPING WITH A NOMINAL
<br />DIAMETER EQUAL TO OR GREATER THAN 3/4 INCH
<br />(19 MILLIMETER) AND LESS THAN 1 INCH.
<br />III. ALL HOT WATER PIPING WITH A NOMINAL
<br />DIAMETER LESS THAN 3/4 INCH THAT IS:
<br />A. ASSOCIATED WITH A DOMESTIC HOT WATER
<br />RECIRCULATION SYSTEM;
<br />B. FROM THE HEATING SOURCE TO THE KITCHEN
<br />FIXTURES;
<br />C. FROM THE HEATING SOURCE TO A STORAGE
<br />TANK OR BETWEEN STORAGE TANKS; OR
<br />D. BURIED BELOW GRADE.
<br />DELTA BREEZSLIM
<br />70 CFM WITH HUMIDITY SENSOR
<br />CFM EXHAUST BATH FAN, WHITE
<br />NOTE :
<br />LUMINAIRES TO BE CONTROLLED
<br />BY EITHER DIMMERS OR
<br />VACANCY SENSORS IN DINING
<br />ROOM AND LIVING ROOM.
<br />DELTA BREEZSLIM
<br />70 CFM WITH HUMIDITY SENSOR
<br />CFM EXHAUST BATH FAN, WHITE
<br />DELTA BREEZSLIM
<br />70 CFM WITH HUMIDITY SENSOR
<br />CFM EXHAUST BATH FAN, WHITE
<br />EQ
<br />EQ
<br />DATE:
<br />P.M.:
<br />DRAWN BY:
<br />JOB NO.:
<br />26081 Merit Cir, STE 111
<br />Laguna Hills, CA 92653
<br />909-257-7040 WWW.BNDESIGNBUILDINC.COM
<br />THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN
<br />DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK
<br />EXCEPT BY AGREEMENT WITH BN DESIGN BUILD.
<br />D ES I GNBUILDCNI
<br />6/
<br />1
<br />2
<br />/
<br />2
<br />0
<br />2
<br />5
<br />
<br />7
<br />:
<br />0
<br />6
<br />:
<br />5
<br />9
<br />
<br />P
<br />M
<br />A2.2
<br />B.N.
<br />S.R.
<br />ELECTRICAL
<br />PLAN
<br />06.10.2025
<br />202500149
<br />1517 W RAYMAR
<br />ST, SANTA ANA,
<br />CA 92703
<br />SINGLE
<br />FAMILY HOME
<br />REV DATE REMARKS
<br />1. FRIDGE (20 AMP)
<br />2. COOKTOP/RANGE (20 AMP, 120/240V)
<br />3. RANGE HOOD (15-20 AMP)
<br />4. COUNTERTOP RECEPTACLES
<br />(2 CIRCUITS, 20 AMP)
<br />5. KITCHEN LIGHTING (15-20 AMP)
<br />6. EACH ROOM/HALLWAY SHALL HAVE SEPARATE CIRCUITS FOR LIGHTS AND
<br />RECEPTACLES
<br />(20 AMP)
<br />7. WALL MOUNTED AIR CONDITIONERS
<br />(20 AMP EACH)
<br />8. BATHROOM RECEPTACLES AND LIGHTS
<br />(20 AMP)
<br />9. BATHROOM FAN (20 AMP)
<br />10. DINING ROOM: SEPARATE (20 AMP) CIRCUIT FOR ENTERTAINMENT
<br />CENTER
<br />ELECTRICAL SYSTEM TO BE INSTALLED ELECTRICAL SYSTEM TO BE INSTALLED
<br />WITH SEPARATE CIRCUITS FOR:WITH SEPARATE CIRCUITS FOR:
<br />GENERAL ELECTRICAL NOTES:
<br />1. THE PROJECT CONTACT AND/OR THEIR LICENSED CONTRACTOR SHALL CONFIRM THE LOCATION,
<br />SIZE AND CAPACITY OF THE EXISTING ELECTRICAL SERVICE ON THE PROPERTY. THE PROPOSED
<br />SERVICE CONNECTIONS FOR THE UNIT SHALL BE VERIFIED AND DETERMINED TO BE VIABLE
<br />CONNECTION PATHS PRIOR TO COMMENCING WORK ON THE PROJECT. IF THE UTILITY LINE OR
<br />CONNECTION IS MISSING, DISPLACED OR OTHERWISE INACCURATE, THE CONTRACTOR AND/OR
<br />PROJECT CONTACT SHALL NOTIFY ALL PARTIES AND A REVISION TO THE PLANS SHALL BE MADE.
<br />2. THE PROJECT CONTACT AND/OR THEIR LICENSED CONTRACTOR SHALL CONFIRM THE PROPOSED
<br />UNIT ELECTRICAL SERVICE LINE'S CAPACITY TO SERVE ALL APPLIANCES AND ELECTRICAL FIXTURES
<br />IN THE UNIT. IF THE PROPOSED ELECTRICAL CONNECTION LINE TO THE UNIT AND INSIDE THE UNIT
<br />ARE MISSING, DISPLACED, INCORRECT CAPACITY OR OTHERWISE INNACURATE, THE CONTRACTOR
<br />AND/OR PROJECT CONTACT SHALL NOTIFY ALL PARTIES AND A REVISION TO THE PLANS SHALL BE
<br />MADE.
<br />3. SUBFEED FROM EXISTING MAIN SERVICE TO PROPERTY: CONTRACTOR TO VERIFY AVAILABLE
<br />CAPACITY FOR ADDITIONAL LOAD (FOR UNIT).
<br />4. ELECTRICAL PANELBOARD SCHEDULE, CIRCUITS, WIRING DIAGRAM, POWER PLAN PERFORMED BY
<br />LICENSED ELECTRICTIAN DURING CONSTRUCTION IN ACCORDANCE TO 2022 CALIFORNIA ELECTRICAL
<br />CODE.
<br />5. ELECTRICAL PANEL GROUNDING ACCORDING TO 2022 CALIFORNIA ELECTRICAL CODE.
<br />6. ALL APPLIANCES AND ELECTRICAL FIXTURES SHALL BE INSTALLED IN ACCORDANCE WITH
<br />MANUFACTURER'S RECOMMENDATIONS AND 2022 CALIFORNIA ELECTRICAL CODE.
<br />7. UNLESS SPECIFIED IN THE SCHEDULE, AN APPLIANCE'S BRAND AND MODEL TBD DURING
<br />CONSTRUCTION, PROVIDED IT MEETS 2022 CALIFORNIA ELECTRICAL CODE.
<br />8. DURING CONSTRUCTION AND INSTALLATION OF THE ELECTRICAL SYSTEM ANY APPLIANCES LISTED
<br />MAY BE REPLACED WITH AN EQUIVALENT MODEL AND BRAND PROVIDED THEY MEET 2022
<br />CALIFORNIA ELECTRICAL CODE AND MEET OR EXCEED ALL APPLICABLE ENERGY STANDARDS IN THE
<br />TITLE 24 REPORT FOR THE PROJECT.
<br />9. ANNULAR SPACES AROUND ELECTRIC CABLES, CONDUITS OR OTHER OPENINGS IN PLATES AT
<br />EXTERIOR WALLS, FOUNDATION, FLOOR OR ROOFTOP SHALL BE PROTECTED AGAINST THE PASSAGE
<br />OF RODENTS BY CLOSING SUCH OPENINGS WITH CEMENT MORTAR, CONCRETE MASONRY OR
<br />SIMILAR METHOD ACCEPTABLE TO THE ENFORCING AGENCY.
<br />1. BATHROOM REQUIRES A DEDICATED 20-AMP CIRCUIT FOR THE REQUIRED BATHROOM OUTLETS.
<br />THIS CIRCUIT CANNOT SUPPLY ANY OTHER RECEPTACLES, LIGHTS, FANS, ETC.. (EXCEPTION: WHERE
<br />THE CIRCUIT SUPPLIES A SINGLE BATHROOM, OUTLETS FOR OTHER EQUIPMENT WITHIN THE SAME
<br />BATHROOM SHALL BE PERMITTED TO BE SUPPLIED. )
<br />2. ALL 120-VOLT, SINGLE PHASE, 15- AND 20- AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS
<br />INSTALLED IN DWELLING UNIT KITCHEN, DINING ROOMS, LIVING ROOMS, BEDROOMS, CLOSETS,
<br />HALLWAYS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC-FAULT CIRCUIT
<br />INTERRUPTER, COMBINATION TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT.
<br />CEC 210.12
<br />1. PROVIDE TAMPER RESISTANT RECEPTACLES, ARCH-FAULT AND GFCI AS REQUIRED BY
<br />APPLICABLE CODES.
<br />2. PROVIDE AFCI PROTECTION FOR ALL OUTLETS OR DEVICES IN A READILY ACCESSIBLE LOCATION
<br />IN KITCHENS, FAMILY ROOMS, DINING, LIVING ROOMS, LIBRARIES DENS, LAUNDRY, OR SIMILAR
<br />ROOMS AND AREAS.
<br />3. TAMPER-RESISTANT RECEPTACLES ARE REQUIRED FOR RECEPTACLES THAT ARE 66" AND LESS
<br />ABOVE THE FINISHED FLOOR, AND IN ANY OF THE FOLLOWING LOCATIONS: KITCHENS, FAMILY
<br />ROOMS, DINING, LIVING ROOM, LIBRARIES DENS, BEDROOMS, RECREATION ROOMS, LAUNDRY, OR
<br />SIMILAR ROOMS OR WALL SPACE. RECEPTACLES IN A DEDICATED SPACE FOR A REFRIGERATOR,
<br />DISHWASHER, OR WASHER/DRYER ARE EXEMPT.
<br />BRANCH CIRCUIT NOTES:BRANCH CIRCUIT NOTES:
<br />RECEPTACLE NOTES:RECEPTACLE NOTES:
<br />1. ALL EXTERIOR LUMINARIES TO BE HIGH EFFICACY AND SHALL MEET THE FOLLOWING
<br />REQUIREMENTS, AS APPLICABLE PER CEC 150.0(K)(3):
<br />A. CONTROLLED BY A MANUAL ON AND OFF SWITCH THAT DOES NOT OVERRIDE TO ON THE
<br />AUTOMATIC
<br />ACTIONS OF ITEMS B) OR C) BELOW; AND
<br />B. CONTROLLED BY PHOTOCELL AND MOTION SENSOR. CONTROLS THAT OVERRIDE TO ON SHALL
<br />NOT BE
<br />ALLOWED UNLESS THE OVERRIDE AUTOMATICALLY REACTIVATES THE MOTION SENSOR WITHIN 6
<br />HOURS; OR
<br />C. CONTROLLED BY ONE OF THE FOLLOWING METHODS:
<br />A. (1) PHOTOCONTROL AND AUTOMATIC TIME SWITCH CONTROL.
<br />B. (2) ASTRONOMICAL TIME CLOCK.
<br />C. (3) ENERGY MANAGEMENT CONTROL SYSTEM.
<br />1. ALL RECESSED LUMINAIRES IN CEILINGS SHALL COMPLY WITH ALL OF THE FOLLOWING:
<br />A. BE LISTED FOR 'ZERO CLEARANCE INSULATION CONTACT (IC)' BY UL (UNDERWRITERS
<br />LABORATORIES) OR OTHER NATIONALLY RECOGNIZED TESTING/RATING LABORATORIES;
<br />B. HAVE A LABEL THAT THE LUMINAIRE IS AIRTIGHT;
<br />C. BE SEALED WITH A GASKET OR CAULK BETWEEN THE LUMINAIRE HOUSING AND CEILING, AND
<br />SHALL HAVE ALL AIR LEAK PATHS BETWEEN CONDITIONED AND UNCONDITIONED SPACES SEALED
<br />WITH A GASKET OR CAULK;
<br />D. SHALL NOT CONTAIN SCREW BASE SOCKETS;
<br />E. SHALL ONLY CONTAIN “HIGH EFFICACY” LIGHT SOURCES OR BE MARKED AS 'JA8-2022-E'
<br />EXTERIOR LUMINAIRES:EXTERIOR LUMINAIRES:
<br />RECESSED DOWNLIGHT LUMINAIRES IN CEILINGS (T24):RECESSED DOWNLIGHT LUMINAIRES IN CEILINGS (T24):
<br />1. ALL LIGHTING SHALL BE HIGH EFFICACY. LAMPS DEEMED AUTOMATICALLY HIGH
<br />EFFICACY NEED ONLY MANUAL ON/OFF SWITCH. IF THE LAMP IS NOT AUTOMATICALLY
<br />HIGH EFFICACY, IT MUST BE JA8 CERTIFIED AND IS REQUIRED TO HAVE A MANUAL
<br />ON/OFF SWITCH PLUS EITHER A VACANCY SENSOR OR DIMMER CONTROL.
<br />2. IN BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS, AT LEAST ONE
<br />LUMINAIRE IN EACH OF THESE SPACES SHALL BE CONTROLLED BY A VACANCY
<br />SENSOR. VACANCY SENSORS SHALL BE INSTALLED IN ALL OF THE ROOM TYPES
<br />LISTED, IF APPLICABLE TO THE PROJECT.
<br />3. ALL LIGHT MOUNTING ACCESSORIES SHALL BE PROVIDED ACCORDING TO LIGHTING
<br />FIXTURE'S MANUFACTURER'S REQUIREMENTS.
<br />4. IF NOT SPECIFIED IN THE SCHEDULE - LIGHT'S BRAND AND MODEL TBD DURING
<br />CONSTRUCTION, PROVIDED IT MEETS 2022 CALIFORNIA ELECTRICAL CODE.
<br />5. DURING CONSTRUCTION AND INSTALLATION OF THE ELECTRICAL SYSTEM ANY LIGHTS
<br />LISTED CAN BE REPLACED WITH EQUIVALENT BRAND/MODEL PROVIDED THEY MEET 2022
<br />CALIFORNIA ELECTRICAL CODE.
<br />LIGHTING NOTES:LIGHTING NOTES:
<br /> 1/4" = 1'-0"1 ELECTRICAL PLAN