Laserfiche WebLink
(N) <br />FURNACE <br />(E) GARAGE <br />(E) MASTER BEDROOM <br />N.I.C <br />(E) BATH <br />(E) <br />KITCHEN <br />(E) BEDROOM #2 <br />(E) CL. <br />(E) BEDROOM #1 <br />(E) BEDROOM #3 <br />N.I.C <br />N.I.C N.I.C <br />N.I.C <br />REF. <br />ENTRY <br />SD SD <br />SD <br />SINK <br />(E) CL. <br />(E) CL. <br />(E) BATH <br />(E) BATH <br />1'-10" <br />2' <br />- <br />6 <br />" <br />(E) ATTIC <br />ACCESS <br />(E) <br />LINEN <br />(E) <br />ELECTRICAL <br />PANEL <br />(E) ATTIC <br />ACCESS <br />AREA OF WORK <br />1'-10" <br />2' <br />- <br />6 <br />" <br />NOTE : <br />-COMBINATION SMOKE & CO ALARMS <br />SMOKE ALARM SHALL BE INTERCONNECTED <br />HARDWIRED WITH BATTERY BACKUP AND <br />SHALL BE INSTALLED IN ACCORDANCE WITH NFPA <br />72. CARBON MONOXIDE ALARM BE <br />INTERCONNECTED HARWARD WITH BATTERY <br />BACKUP. <br />-SMOKE ALARM SHALL BE INSTALLED NOT LESS <br />THAN 3FT HORIZONTALLY FROM THE DOOR OF THE <br />BATHROOM PER 2022 CRC, SECTION R314.3. <br />-SMOKE ALARMS SHALL BE INSTALLED A MINIMUM <br />OF 20FT HORIZONTAL DISTANCE FROM A <br />PERMANENTLY INSTALLED COOKING APPLIANCE OR <br />PLEASE SHOW THAT IONIZATION OR <br />PHOTOELECTRIC SMOKE ALARMS SHALL BE <br />PROVIDED IN ACCORDANCE WITH 2022 CRC, <br />SECTION R314.3.3 ITEM 4 EXCEPTION. <br />(E) GAS METER <br />(E) STORAGE <br />(E) GATE <br />(E) GATE <br />(E) DRIVEWAY <br />(E) CONCRETE PAD <br />(E) BLOCK FENCE <br />(E) BLOCK FENCE <br />P. <br />L <br />. <br /> <br />10 <br />2 <br />' <br />P. <br />L <br />. <br /> <br />10 <br />2 <br />' <br />4'-0"3'-6" <br />(N) ISLAND <br />4' <br />- <br />4 <br />" <br />10 <br />' <br />- <br />0 <br />" <br />2' <br />- <br />0 <br />" <br />3'-0" <br />2'-4" <br />3' <br />- <br />0 <br />" <br />8'-0"5' <br />- <br />0 <br />" <br />EQ <br />EQ <br />(N) WALK <br />IN CLOSET <br />3'-0" <br />4 <br />1 <br />/ <br />2 <br />" <br />2' <br />- <br />4 <br /> <br />1 <br />/ <br />2 <br />" <br />(N) BATH <br />4' <br />- <br />4 <br />" <br />8'-11"2'-0" <br />(E) <br />TANK <br />W.H. <br />2'-10" <br />2'-8" <br />2' <br />- <br />8 <br />" <br />(E) LIVING ROOM <br />2.98 <br />8' <br />- <br />1 <br />" <br />8'-0" <br />2.18 <br />2.51 <br />2.3 <br />02 <br />2.3 <br />2.1 <br />01 <br />SAFETY GLAZING <br />2.56 <br />2.18 <br />2.18 <br />2.18 <br />S/C <br />2.98 <br />P.L. 60.40' <br />NOTE: <br />CONTRACTOR TO VERIFY ALL <br />DIMENTIONS/DISTANCE IN THE FIELD. <br />01 <br />02 <br />3'-0" <br />2' <br />- <br />9 <br />" <br />EX. WALL TO REMAIN <br />EX. WALL TO BE REMOVED <br />AREA NOT IN <br />CONTRACT (N.I.C.) <br />EX. DOOR TO REMAIN <br />1 <br />2 <br />3 <br />INTERIOR WALL <br />1 HOUR FIRE <br />RATED WALL <br />EXTERIOR WALL <br />FLOOR <br />CEILING <br />ROOF <br />2 <br />B <br />3 <br />C <br />1 <br />A <br />TYPICAL, FIRE RATED WALL <br />2X4 WOOD STUDS @ 16" O.C. w/ 5/8" <br />TYPE 'X' GYP. ONE. SIDE W/ SOUND <br />INSULATION <br />INTERIOR WALL <br />2X4 WOOD STUDS @ 16" O.C. w/ 1/2" <br />BD. EA. SIDE w/ SOUND INSULATION <br />EXTERIOR WALL <br />1/2" GYP. BD. 2X4 WOOD STUDS @ 16" O.C. <br />INSULATION R -15 w/ 5/8" PLYWOOD, 2 LAYERS <br />BUILDING PAPER, METAL LATH, 7/8" STUCCO <br />- 01- <br />POCKET DOOR <br />SE <br />E <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br />SEE SCHEDULE <br />- 02- <br />SINGLE DOOR <br />SE <br />E <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br />SEE SCHEDULE <br />CASEMENT WINDOW - 01 - <br />SAFETY <br />GLAZING <br />SE <br />E <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br />VI <br />F <br />3' <br />- <br />0 <br />" <br />SEE SCHEDULE <br />DATE: <br />P.M.: <br />DRAWN BY: <br />JOB NO.: <br />26081 Merit Cir, STE 111 <br />Laguna Hills, CA 92653 <br />909-257-7040 WWW.BNDESIGNBUILDINC.COM <br />THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN <br />DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK <br />EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. <br />D ES I GNBUILDCNI <br />6/ <br />1 <br />2 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />7 <br />: <br />0 <br />6 <br />: <br />5 <br />7 <br /> <br />P <br />M <br />A2.1 <br />B.N. <br />S.R. <br />PROPOSED <br />FLOOR PLAN <br />06.10.2025 <br />202500149 <br />1517 W RAYMAR <br />ST, SANTA ANA, <br />CA 92703 <br />SINGLE <br />FAMILY HOME <br />0 2'-0"4'-0"8'-0" <br />SCALE: 1/4" = 1'-0" <br />REV DATE REMARKS <br /> 1/4" = 1'-0"1 PROPOSED FLOOR PLAN <br />PROPOSED KEYNOTES <br />2.1 PROPOSED NEW WINDOWS <br />2.3 PROPOSED NEW WALL <br />2.18 BATHROOMS: ALL FIXTURES AND FINISHES AS SELECTED. TANK TYPE <br />PORCELAIN WATER CLOSET . ENAMEL LAVS. PROVIDE PLUMBING PER <br />CODE FOR ALL FIXTURES AND SEPARATE SHOWER. MIRROR OVER <br />LAVS AS SELECTED BY INTRIOR DESIGN CONSULTANT OR <br />CONTRACTOR. <br />2.51 PROPOSED NEW POCKET DOOR <br />2.56 PROPOSED NEW ISLAND <br />2.98 NEW CEILING DRYWALL UNDER EXISTING RAFTERS/R-30 INSULATION <br />DOOR SCHEDULEDOOR SCHEDULE <br />DOOR <br />NUMBER <br />NAME. <br />TYPE <br />DOOR DIMENSION DOOR MATERIAL & FINISH <br />FRAME MATERIAL & <br />FINISH <br />HARDWARE <br />HARDWARE <br />W H T MATERIAL FINISH <br />GLASS <br />FINISH MATERIAL FINISH EX <br />I <br />T <br /> <br />D <br />E <br />V <br />I <br />C <br />E <br />FI <br />R <br />E <br />- <br />R <br />A <br />T <br />E <br />D <br />01 3' - 0"6' - 8"1 3/4"WOOD FF FF <br />02 2' - 6"6' - 8"1 3/4"WOOD FF FF <br />CONTRACTOR TO VERIFY ALL SIZES IN THE FIELD PRIOR TO ORDERING DOORS. <br />GENERAL NOTES <br />1- CONTRACTOR SHALL NOT SCALE , DRIVER OR REQUEST DIMENSIONS FROM THE STRUCTURAL <br />ENGINEER, PLUMBING ENGINEER,CIVIL ENGINEER OR ELECTRICAL ENGINEER... FOR ANY ITEMS ON THE <br />DOCUMENTS. ALL DIMENSIONS NEEDED WILLBE REQUESTED OF THE DESIGNER IN WRITING IN THE <br />FORM OF AN RFI.(FAILURE TO ADHERE TO THIS PROCESS WILLRESULT IN DENIAL OF CHANGE ORDERS ) <br />2- GENERAL CONTRACTOR SHALL NOT EXCLUDE (ANY) PORTION OF WORK, OR RELATED WORK FOR <br />(ANY)PORTION OF THE WORK SHOWN OR REFERENCED ON THE DOCUMENTS. <br />A. ALL DIMENSIONS FOR THE PROJECT SHALL BE OBTAINED FROM THE DESIGNERURAL DRAWING,IN THE <br />EVENT THAT THEY ARE NOT PROVIDED THE GC SHALL ASK THE DESIGNER IN WRITING IN THE FORM OF <br />AN RFI. <br />B. IN THE EVENT OF ANITEM BEING UNCLEAR ON THE DRAWINGS DURING BIDDING,THE GC SHALL ASK(IN <br />A BID RFI)TO THE DESIGNER FOR THE INFO, THE GC SHALL ASK THIS INFO IN A TIMLY MANNER SO AS TO <br />GIVE THE DESIGNER TIME TO ANSWER AND DISTRIBUTETO ALL PARTIES. IN TEH EVENT THAT THE GC <br />FAILS TO CLARIFY THIS INFO DUE TO OVERLOOKING IT OR NOT RECEIVING AN ANSWER FORM <br />THEDESIGNER, GC SHALL IDENTIFY THE ITEM/S IN QUETION IN THEIR BID CLARIFICATIONS. <br />C. GC SHALL REVIEW ALL SUBCONTRACTOR SCOPE TO THE FULL-SET OF DOCUMENTS,IT IS GC <br />RESPONSIBILITY TO UNDERSTAND AND DISCUSS SUB-CONTRACTOR SCOPE ATTHE TIME OF BID TO THE <br />POINT THAT THEY FEEL COMFOR TABLE THAT THE DRAWING INTENT HAS BEEN SATISFIED. ANY <br />UNCLEAR ITEMS SHALL BE DISCUSSED WITH THE SUBCONTRACTOR TO CLARIFY THE NEED FOR A BID <br />RFI <br />3- ALL DIMENSIONS ARE TO STRUCTURE-FACE OF FINISHES OR STRUCTURE CONCRETE WALL. <br />4- GENERAL CONTRACTOR TO VERIFY ALL DOOR FRAME WIDTHS,COORDINATE WITH WALL TYPE <br />SCHEDULE FOR WALL THICKNESS REFER TO DOOR SCHEDULE. <br />5-PROVIDE OPENING FOR DOOR SIZE SCHEDULE, JAMBS ARE FLUSH AS SHOWN OR AS DIMENSIONED <br />GREEN CODE BUILDING <br />1. THE FLOW RATES FOR ALL PLUMBING FIXTURES SHALL COMPLY WITH THE MINIMUM FLOW RATES IN <br />TABLE 4.303.2/TABLE 9.403.2. (4.303.1 <br />PLUMBING NOTES <br />1. PROVIDE A NON-REMOVABLE BACKFLOW PREVENTION DEVICE ON ALL EXTERIOR HOSE BIBS, AND <br />LAWN SPRINKLER / IRRIGATION SYSTEMS. <br />WALL LEGEND <br />RE <br />F <br />. <br /> <br />N <br />O <br />R <br />T <br />H <br />DOOR TYPEDOOR TYPE <br />Window Schedule <br />Window Type Width Height Sill Height Finish Comments <br />01 2' - 0"4' - 0"3' - 0".U - FACTOR 0.3, SHGC 0.23 <br />WINDOW SCHEDULEWINDOW SCHEDULE <br />WINDOW TYPEWINDOW TYPE <br />CONTRACTOR TO VERIFY ALL SIZES IN THE FIELD PRIOR TO ORDERING WINDOWS. <br />FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT LABELS <br />FOR VERIFICATION OF THE BUILDING INSPECTOR.” 110.6(A)(5) <br />NO WORK TO STRUCTURAL