Laserfiche WebLink
O EQUIPMENT SCHEDULE <br />TAG DESCRIPTION <br />1 SOLAR PV MODULE <br />2: PV ARRAY <br />3 J-BOX <br />4 D.C/AC INVERTER <br />5 AC DISCONNECT <br />6 MAIN SERVICE PANEL <br />NOTES <br />PHONO SOLAR PS300P-24/T 300W <br />12 MODULES <br />DIMENSION 4"X4")<2" <br />PVI-3.6-OUTD-S-US(240) <br />DU221 RB 30A,240VAC, NON-FUSIBLE, 2POLE <br />200A BUS-200 A MAIN 20 A INV OCPD,120/240V, 1 0 <br />A CONDUIT AND CONDUCTOR SCHEDULE <br />TAG DESCRI;PTION GAUGE # COND. <br />1 PV-WIRE #10 2 <br />2 THWN-2 (ECG) #8 1 <br />3 TH WN-2 #10 2 <br />4 THWN-2 #10 3 <br />5 BARE COOPER (GEC) #6 1 <br />CONDUIT TYPE CONDUIT SIZE LENGHT FT. % VD <br />N/A N/A 30 0.17 <br />N/A N/A 30 N/A <br />EMT 0.75"100 0.56 <br />EMT 0.75"<10 0.17 <br />N/A N/A 8 N/A <br />PROJECT TEAM <br />TRUE POWER SOLAR <br />451 W LAMBERT, <br />TRUE POWER SUITE 212 <br />Ik SOLAR BREA, CA 92821 <br />TEL: (714) 676·8888 <br />LICENCE: CSLB# 970591 <br />(B.C46) <br />PHOTOVOLTAIC SYSTEM SUMMARY <br />SYSTEM SIZE- ( 3600 ) W OC <br />MODULES: ( 12) PHONO SOLAR PS300P-24/T <br />MODULE MAX POWER (P MAX).300W <br />INVERTER: PVI-3.6-OUT[)-S-US(240) <br />RECOMMENDED MOUNTING SYSTEM UNI RACK <br />ARRAY TILT: 18 DEGREES <br />AZIMUTH: 163 DEGREES <br />© 1) UTILITY <br />M) 'SERVICE <br />7 -f 200A BUS <br />NOTE: PV BREAKER200 A MAIN <br /> POSITIONED AT THE OPPOSITEEND OF THE MAIN BREAKER. <br />3/4" <br />co'NDUIT Ii,NOTE: SUM OF THE SERVICE <br />MAIN BREAKERAND BACKFEED <br />BREAKER IS LESS THAT 120% <br />OF SERVICE BUS RATING. <br />/4\ 11 ,®neGGs <br />6' -3/4··C-1#4 <br />MIN (N) <br />63*--@ GROUND RODS 6'-0" <br />(2) 3/4- ® x 10' <br />APART TYPICAL <br />6 MODULES IN <br />SERIES SOURCE CIRCUIT 2-1 n <br />6 MODULES IN | 1 <br />SERIES SOURCE CIRCUIT ·wl- - 461- - -0.12.1 <br />4 22 <br />f <br />3/4'· <br />- -- ----CONDUIT ---INVERTER <br />1 /3\1 -ZE \AC 120V AC 3/4;" <br />Lf \120VAC -CONDUIT <br />NEUTRAL - <br />1 " <br />®-12 <br />L---J- -- -El- - - 1-/CONDUIT*_ -- GEC1 /5\ <br />A <br />12 <br />4 <br />1 <br />-A 20 A <br />ELECTRICAL INFORMATION <br />UTILITY COMPANY. SCE <br />MAIN SERVICE vOLTAGE 240V SINGLE PHASE <br />MAIN SERVICE AMPEF?AGE: !EXISTING 200A BUS- 200 A MAIN <br />BUILDING INFORMATION <br />OCCUPANCY: RESIDENTIAL <br />NUMBER OF FLOORS: 1 <br />ROOF INFORMATION (SITE VERIFY) <br />TYPE: COMP SHINGLE <br />SHEETINDEX <br />Tl TITLE PLAN <br />GENERAL NOTES PV SYSTEM SUMMARY <br />PV1 PLOT PLAN/ROOF PLAN <br />PV2 RACKING DETAIL <br />PV3 RACKING DETAIL CONT/EQIPMENT ELEVATION <br />PV4 ELECTRICAL SINGLE LINE DIAGRAM, <br />PV-C CALCULATIONS <br />PV-C2 WIRE AMPACITIES <br />PV-NOTES PLACARDS NOTES <br />SPECIAL NOTES: <br />CNVERTER ELECTRJCAL. SPECIFIA¢TONS <br />INVERTER BRAND: PVI-3.6-OUTD-US 240 <br />INPUT (DC)] <br />MAC DC POWER 37 <br />MAX INPUT VOLTAGE 60 <br />MPP VOLTAGE RANGE 12 <br />MIN INPUT VOLTAGE 12 <br />MAX INPUT CURRENT IN-A/IN B 16 <br />MAX INPUT CURRENT PER STRING IN-A/IN B 16 <br />NUMBER OF INDEPENDENT MPP INPUTS 2 <br />*mw 04 <br />RATED POWER 36 <br />MAX APPARENT AC POWER 36 <br />AC POWER FREQ. 50 <br />RATED POWER FREQ./GRID VOLTAGE 50 <br />MAX OUTPUT CURRENT 16 <br />POWER FACTOR AT RATED POWER 1 <br />FEED-IN-PHASES/CONNECDON PHASES 1/ <br />NOTE: <br />1. GROUNDED ELECTRODE CONDUCTOR MUST <br />BE PROTECTED FROM PHYSICAL DAMAGE <br />BETWEEN THE GROUNDING ELECTRODE AND <br />50 W THE PANEL (OR INVERTER) IF SMALLER THAN #6 <br />COPPER WIRE (NEC. 250.6413) <br />0' V 2. GROUNDING ELECTRODE CONDUCTOR WILL <br />BECONTINUOUS, EXCEPT FOR SPLICES OR <br />OV-500V JOINTS AT BUSBAR WITHIN LISTED EQUIPMENT <br />(NEC 250.54 C)0V 3.GROUNDING CONNECTORMUST BE <br />A CONTINUOUS SPLICE DONE WITH AN <br />IRREVERSIBLE COMPRESSION Cl-AMP <br />A <br />MODULCELECIRIC-4- _SPE@El*®NS <br />oow PV MODULE BRAND: PHONO PS300P-24/T <br />OOVA PERFORMANCE UNDER STANDARD TEST CONDITIONS (S <br />-60 HZ MAXIMUM POWER MAX 300 Wi <br />HZ-230V OPEN CIRCUIT VOLTAGE Voc 45.6 V <br />A MAXIMUM POWER POINT VOLTAGE VPP 35.6 V <br />SHORT CIRCUIT CURRENT 'sc 8,65 A <br />1 MAXIMUM POWER POINT CURRENT IMPP 8.44 A <br />AC DISCONNECT NOTE: <br />DISCONNECT SHOULD BE <br />CONNECTED WITH INVERTER <br />ENERGIZEDOUTPUTAT <br />BOTTOM IF SWITCH SO <br />BLADES WILL BE NOT <br />ENERGIZED WHEN THE <br />SWITCH IS IN OPEN <br />POSITION. <br />TC) <br />DC SYSTEM GND <br />ELECTRODE <br />3/4" C-1#4 <br />"RACEWAY FOR <br />GROUNDING <br />ELECTRODE <br />CONDUCTOR SHALL <br />BE BONDED AT <br />EACH END" CEC <br />250.64(E) <br />NOTE: <br />IN EXISTING <br />ELECTRICAL SYSTEMS <br />THAT USE ONLY A <br />WATER PIPING <br />GROUNDING <br />ELECTRODE iSYSTEM, <br />AND ADDITIONAL <br />GROUNDING <br />ELECTRODE <br />(I.E. DRIVEN ROD) <br />SHALL BE PROVIDED <br />(NEC 250.50) <br />N <br />CUSTOMER INFORMATION <br />SILVIARUIZ <br />2226 W. BOBBY LN <br />SANTA ANA, CA 92706 <br />PHONE: 714-750-3261 <br />DATE DRAFTER <br />DRAWN <br />CHECKED <br />APPROVED <br />DATE REVISIONS <br />1HOMAS GUIDE <br />NTS <br />FILENAME <br />RUIZ_A.DWG <br />SOLAR P/ENGINEER <br />CHRISTIAN RUIZ <br />lELEPHONE NlailaER <br />602-330-3375 <br />EMAILADORESS <br />CHRISTIANRUIZING@GMAILCOM <br />PROJECTMANAGER <br />TRUE POWER SOLAR <br />PROJECT MANAGER TELEPHONEt <br />714-678-8888 <br />PEFal,TRLIKER <br />JURIDICHONMANCHECKER <br />SHEET: <br />SINGLE-LINE <br />PAGE <br />PV4 <br />I & <br />7