Laserfiche WebLink
MAXIMUM PV SYSTEM VOLTAGE: <br />EACH MODULE OPEN CIRCUIT VOLTAGE (Voc) = 45.6 V <br />TEMPERATURE CORRECTION FACTOR 1.12 (PER NEC TABLE 690.7) <br />MAXIMUM PV SYSTEM VOLTAGE 1.12 X 45.6 V= 51.07 V DC <br />51.07 V DC X 6 MODULES= 306.42 VDC TO INVERTER1 INPUT 1 MPPT 1 <br />51.07 V DC X 6 MODULES= 306.42 VDC TO INVERTER1 INPUT 2 MPPT2 <br />PVI-3.6-OUTD-S-US OPERATING WINDOWS FOR BEST MPP TRACKING 120V-530V. <br />MIN INPUTVOLTAGE 120V <br />MAXIMUM PV SYSTEM CURRENT IS CALCULATED IN ACCORDANCE WITH ARTICLE 690.8 <br />MODULE SHORT CIRCUIT CURRENT (ISC) = 8.65 A <br />1.25 X 8.65 A = 10.81 A <br />10.8 AX 1.25= 13.51A I MAX FOR WIRE AMPACITY. <br />PVI-3.6-OUTD-S-US MAX INPUT AMPERAGE PER STRING INPUT 16A <br />OCPD IN MAIN PANEL IS = 200 A MAI N <br />THE SERVICE PANEL BUS RATING RATING IS = 200A BUS <br />THE INVERTER1 & 2 OUTPUT CONDUCTOR OCPD IS = 20 A <br />THE SUM OF INVERTER OCPD AND MAIN OCPD = 20 A + 200 A MAIN =220 A <br />PER NEC 690364 (B) (2), THE SUM OF 220 A >PANEL BUS RATING <br />200A BUS X 1.2 = 240 A IF YES STOP. CALCULATION COMPLETED. <br />PROJECT TEAM <br />TRUE POWER SOLAR <br />451 W LAMBERT,24 TRUE POWER SUITE 212 <br />A SOLAR BREA CA 92821 <br />iII.TEL· (714,676-8888 <br />LICENCE: CSLB#i970591 <br />(B.C46) <br />PHOTOVOLTAIC}SYSTEM SUMMARY <br />SYSTEM SIZE: ( 3600 ) W DC <br />MODULES. ( 12) PHONO SOLAR PS300P-24/T <br />MODULE MAX POWER (P MAX):300W <br />INVERTER PVI-3 6-OUTD-S-US(240) <br />RECOMMENDED MOUNTING SYSTEM: UNI RACK <br />ARRAY TILT: 18 DEGREES <br />AZIMUTH:163 DEGREES <br />ELECTRICAL INFORMATION <br />UTILITY COMPANY: SCE <br />MAIN SERVICE VOLTAGE· 240V SINGLE PHASE <br />MAIN SERyICE AMPERAGE: EXISTING 200A BUS- 200 A MAIN <br />BUILDiNG INFORMATION <br />OCCUPANCY· RESIDENTIAL <br />NUMBER OF FLOORS: 1 <br />RCOF INFORMATION {SITE VERIFY)! <br />TYPE: COMP SHINGLE <br />SHEETINDEX <br />Tl TITLE PLAN <br />GENERAL NOTES PV SYSTEM SUMMARY <br />PV1 PLOT PLAN/ROCF PLAN <br />PV2 RACKING DErAll <br />PV3 RACKING DETAIL CONT./EQIPMENT ELEVATION <br />PV4 ELECTRICAL SINGLE LINE DIAGRAM <br />pvy¢CALCULATIONS <br />PV-et!WIRE AMPACITIES <br />PV-NOTES PLACARDS NOTES <br />SPECIAL NOTES: <br />CUSTOMER INFORMATION <br />SILVIA RUIZ <br />2226 W BOBBY LN <br />SANTA ANA, CA 92706 2h. <br />PHONE: 714-750-3261 <br />SOLARIVENINEER <br />DATE DRAFTER CHRISTIAN RUIZ <br />TELEPHONE NuwIBER <br />DRAWN 42- 602.330.3375 <br />CHECKED CHRISTIANRUIZING@GMAIL.COM <br />PROJECTMANAGER <br />APPROVED TRUE POWER SOLAR <br />PROJECTMANCERTELEPHONE <br />DATE REVISIONS 714-676·8888 <br />PERT RUNVER <br />JUR,SOICNONPLANCHECKER <br />SI·*EET: <br />CALCULATIONS <br />SCALE THOMAS GpIDE <br />NTS PACE: <br />FILENAME: <br />RUIZ_ADWG PV-C