147 SIGN COMPONENTS MANUAL (SAM)October 1, 2013
<br />LED Accent Module, Mega, Accent or Right Light Series, Model Q ABC-XX-YY-ZZZZ series, where Q may be P, M, AC or blank,
<br />AB, XX and YY may be replaced by any alphanumeric characters (0 to 9 incl. or A to ZZ incl. or combinations), C may be blank
<br />or may be any alphanumeric characters (0 to 9 incl. or A to Z incl. or combinations); and ZZZZ may be any alphanumeric
<br />characters (0 to 9999 incl. or A to zzzz incl. or combinations) or blank.
<br />1. These products are only suitable for connection to a Class 2 power source, rated max 24 Volt DC or less.
<br />2. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 voltage
<br />and energy limited circuit.
<br />3. These Class 2 LED Modules are each rated 0.77 Watts per unit. When units are connected to a Class 2 circuit, they are not to
<br />draw a total wattage of greater than the secondary or output rating of the Class 2 supply.
<br />4. These products are suitable for use in dry, damp and wet locations with supply sources rated at 12 Volt DC or less. When rated
<br />24 VDC, these products are suitable for dry and damp locations only.
<br />5. These products are not required to be enclosed or protected from the weather in the end product.
<br />LED Accent LED module, Model AC-X-Y-Z-T, where X is the length of the module, Y identifies the operating voltage, Z identifies
<br />the color, and T identifies a standard.
<br />1. These products are only suitable for connection to a UL Listed or Recognized Class 2, max 30 Vdc only power source.
<br />2. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 voltage
<br />and energy limited supplies.
<br />3. These products are not provided with break points in the printed wiring board. No cuts across the board is permitted.
<br />4. These products are suitable for use in dry, damp, and wet locations.
<br />5. These products are not required to be enclosed or protected from weather.
<br />Right Light Series LED module "Right Light", Models TP-2-12-z, abc-X-Y-Z and RLS-X-Y-Z, where X may be any number from 0
<br />to 9, Y may be any number from 00 to 99, and Z may be any alphanumeric character..
<br />1. These products are only suitable for connection to a UL Listed or Recognized Class max. 24 VDC power source.
<br />2. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 voltage
<br />and energy limited supplies.
<br />3. These products are not provided with break points in the printed wiring board. No cuts across the board are permitted.
<br />4. These products are suitable for use in dry, damp, and wet locations.
<br />5. These products are not required to be enclosed or protected from weather.
<br />LED Driver Enclosure, Model Life Extender Box.
<br />1. This product has been evaluated for Dry and Damp Locations only. If used in a wet location, Rain Testing shall be conducted
<br />during the end product evaluation.
<br />Class 2 LED Module, Models EXSA-1-6, EXSA-1-12.
<br />1. These products are intended for use only when connected to a power source that complies with Class 2 voltage and energy
<br />limited circuit and is rated less than 24V DC.
<br />2. When these units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output
<br />rating of the Class 2 supply.
<br />3. These products are suitable for use in dry, damp and wet locations with supply sources rated at 12 Volt DC or less. When rated
<br />24 VDC, these products are suitable for dr'y and damp locations only.
<br />4. These products do not require an electrical enclosure. The 24Vdc modules require protection from the weather in the end
<br />product, as they are not suitable for wet locations. The 12Vdc modules require no such protection.
<br />5. These products may be secured in place in the end product by any means available.
<br />Class 2 LED Module, Models Tandem XX and Tandem XX Dual, where XX, a non-safety related designation, may be any
<br />alphanumeric character.
<br />1. These products are intended for use only when connected to a power source that complies with Class 2 voltage and energy
<br />limited circuit and is rated less than 24V DC.
<br />2. When these units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output
<br />rating of the Class 2 supply.
<br />3. These products are suitable for use in dry, damp and wet locations with supply sources rated at 15 VAC or 30 V DC max.
<br />4. These products do not require an electrical enclosure.
<br />5. These products may be secured in place in the end product by any means available.
<br />Class 2 LED Module,"BEl" series, designated as Models BEl-W-XY-ZZ series, Where W may be any number from 0 to 9, X may
<br />be any number from 0-9, Y may be L or Hand ZZ may be any two digit number between 0-9.
<br />1. These products are only suitable for connection to a UL Listed or Recognized Class 2 power source with max. 24 VDC.
<br />2. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 voltage
<br />and energy limited supplies.
<br />3. These products are provided with break points in the printed wiring board. No cuts across the board are permitted except where
<br />indicated in the installation instructions.
<br />4. These products are suitable for use in dry, damp, and wet locations.
<br />5. These products are not required to be enclosed or protected from weather.
<br />6. These products may be secured in place in the end product by any means available
<br />UNILUMIN GROUP CO LTD E330828
<br />BLDG A, 112 YONGFU RD
<br />QIAOTOU, FUYONG TOWN
<br />BAOAN DISTRICT
<br />SHENZHEN, GUANGDONG 518103 CHINA
<br />Changing Message Signs, Model P16.
<br />1. Maximum of 2 units when installed in a 15 Amp branch circuit and 3 units for a 20 Amp branch circuit.
<br />2. This product was tested for use at a room ambient temperature of 25°C. Testing was conducted on an open bench positioned in
<br />a vertical position facing horizontally. The need for conducting temperature testing in the end product shall be considered where
<br />the units are installed in a higher ambient,
<br />3. The suitability of the mounting means shall be determined in the end use.
|