Laserfiche WebLink
2422 W. Marty Lane <br /> October 2, 2025 <br /> Page: 3 <br /> <br />Additional expansion index tests need to be performed after completion of pad to verify that the <br />expansion index of the underlying soils is as stated above. If the test results indicate that the <br />underlying soils are not classified as very low expansive soils for the area of the proposed slab-on- <br />grade, the recommendations below should be adjusted accordingly. <br /> <br />Other professionals in the design team may have different concerns depending on their own <br />discipline and experience. Therefore, our recommendations should be considered as minimum and <br />should be superseded by more restrictive recommendations of other members of the design team or <br />the governing agencies, if applicable. <br /> <br />Footing Design. The following minimum criteria should be adopted for the footing design: <br />a. Allowable Bearing Capacity: qall = 1,500 psf <br />b. Minimum Footing Width: 12 inches <br />c. Minimum Footing Depth: 18 inches <br />d. Minimum Reinforcement: 2 # 5 bars at both the top and bottom in continuous <br />footings <br />Notes: <br />i. Depth of footing is measured from the lowest adjacent grade. <br />ii. Allowable bearing capacity may be increased by one-third for short-term wind or <br />seismic loads. <br />iii. The above-mentioned footing dimensions recommendations should not be considered <br />to preclude more restrictive criteria of regulating agencies or by the structural <br />engineer/architect. <br />iv. The design of the foundation system should be performed by the project structural <br />engineer, incorporating the geotechnical parameters described above. <br /> <br />Slab Design. The following recommendations should be incorporated for the slab-on-grade design: <br />a. The minimum thickness of slab-on-grade should be 5 inches. <br />b. The minimum steel reinforcement for slab-on-grade should be # 4 located at mid- <br />height on 18-inch centers both ways (or equivalent). <br />c. A modulus of subgrade reaction of 100 lb/in2/in may be utilized for the slab design <br />d. Moisture barrier (visqueen) of a minimum 10-mil thick should be placed-in below <br />the slab; and located in middle of a minimum of 4 inch thick of sand that is placed <br />underneath the slab in accordance with an equivalent method specified in Section <br />4.505.2.1 of the California Green Code. <br /> <br />Concrete Flatworks. The minimum thickness for concrete flatworks is 4 inches in order to minimize <br />potential for excessive cracks. In addition, construction joints or weakened plane joints should be <br />provided at 6-foot frequent intervals. <br /> <br /> <br /> <br /> <br />