My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2437 S Lowell St - Plan
PBA
>
Building
>
ProjectDox
>
L
>
Lowell St
>
2437 S Lowell St
>
2437 S Lowell St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/10/2025 5:00:09 AM
Creation date
12/10/2025 5:00:05 AM
Metadata
Fields
Template:
Plan
Permit Number
20187291
Full Address
2437 S Lowell St
Street Number
2437
Street Direction
S
Street Name
Lowell
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
projects@evengineersnet.com <br />http://www.evengineersnet.com <br />Wind (Uplift Check) <br />DCR check=0.35 CONNECTION PASS <br />Vertical Load Resisting System Design <br />Gravity Load Check <br />Roof Dead Load <br />Roof Dead Load 10.0 psf <br />PV Dead Load 3.0 psf <br />Roof Live Load 20 psf <br />PV Roof Live Load 0 psf <br />Snow Load 0 psf <br />IEBC Check <br />Existing With PV <br />Roof Dead Load (D)10.0 13.0 psf <br />Roof Live Load (Lr)20.0 0.0 psf <br />Roof Snow Load (S)0.0 0.0 psf <br />Cs=1 1.00 <br />Existing With PV <br />(D + Lr) = 24.0 14.4 psf <br />(D + S) = 8.7 11.3 psf <br />Maximum Gravity Load 24.0 14.4 psf <br />Load Increase (%)-39.8%OK <br />IBC Provision 2021 <br />Siesmic Loads Check <br />Roof Dead Load 10 psf <br />% or Roof with Pv 23.42% <br />Dpv and Racking 3 psf <br />Average Total Dead Load 10.7 psf <br />Increase in Dead Load 3.5%OK <br />Limits of Scope of Work and Liability <br />*The requirements of Section 806.2 of the 2018 IEBC are met and the structure is <br />permitted to remain unaltered. <br />The Existing structure is assumed to have been designed and constructed following appropriate codes and to have <br />appropriate permits. The analysis was according to applicable building codes, professional engineering and design <br />experience, opinions and judgments. This evalution produced for this structure's assessment is only for the proposed <br />solar panel installation referenced in the stamped plan set and were made according to generally recognized structural <br />analysis standards and procedures. Prior to commencement of work, the contractor shall verify the framing sizes, <br />spacings, and spans. Contractor shall also verify that there is framing damage or deficiencies. If observed, the EOR must <br />be notified before install. <br />The increase in seismic Dead weight as a result of the solar system is less than 10% of the existing structure and therefore <br />no further seismic analysis is required.
The URL can be used to link to this page
Your browser does not support the video tag.