2437 S Lowell St - Plan
PBA
>
Building
>
ProjectDox
>
L
>
Lowell St
>
2437 S Lowell St
>
2437 S Lowell St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/10/2025 5:00:09 AM
Creation date
12/10/2025 5:00:05 AM
Metadata
Fields
Template:
Plan
Permit Number
20187291
Full Address
2437 S Lowell St
Street Number
2437
Street Direction
S
Street Name
Lowell
Street Suffix
St
Stamp
ID:
1
Creator:
Import Agent
Created:
12/10/2025 5:00 AM
Modified:
12/9/2025 5:06 PM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
BACKUP LOADS <br />LOAD BREAKER RATING <br />(AMPS)LABEL DEMAND <br />LOAD <br />1 15A-1P LIGHTENING / RECEPTACLES 1500 W <br />2 20A-1P LIGHTENING / RECEPTACLES 1500 W <br />3 20A-1P LIGHTENING / RECEPTACLES 1500 W <br />4 30A-2P DRYER 5760 W <br />5 40A-2P A/C 7680 W <br />6 15A-1P LIGHTENING / RECEPTACLES 1500 W <br />7 20A-1P LIGHTENING / RECEPTACLES 1500 W <br />8 20A-1P LIGHTENING / RECEPTACLES 1500 W <br />9 15A-1P LIGHTENING / RECEPTACLES 1500 W <br />10 15A-1P LIGHTENING / RECEPTACLES 1500 W <br />11 15A-1P LIGHTENING / RECEPTACLES 1500 W <br />12 20A-1P LIGHTENING / RECEPTACLES 1500 W <br />13 20A-1P LIGHTENING / RECEPTACLES 1500 W <br />14 20A-1P LIGHTENING / RECEPTACLES 1500 W <br />15 20A-1P LIGHTENING / RECEPTACLES 1500 W <br />16 20A-1P LIGHTENING / RECEPTACLES 1500 W <br />17 20A-1P LIGHTENING / RECEPTACLES 1500 W <br />18 20A-1P LIGHTENING / RECEPTACLES 1500 W <br />19 20A-1P LIGHTENING / RECEPTACLES 1500 W <br />CONDUIT SCHEDULE <br />TAG CIRCUIT DESCRIPTION CONDUCTOR NEUTRAL GROUND CONDUIT <br />1 Inverter Input (2) 10 AWG (PV WIRE)N/A 6 AWG (BARE)Open Air <br />2 Inverter Input (8) 10 AWG <br />THHN/THWN-2 N/A 8 AWG THHN/THWN-2 3/4 EMT <br />3 Inverter Output (2) 6 AWG <br />THHN/THWN-2 <br />(1) 6 AWG <br />THHN/THWN-2 8 AWG THHN/THWN-2 3/4 EMT <br />4 GATEWAY OUTPUT (2) 3 AWG <br />THHN/THWN-2 <br />(1) 3 AWG <br />THHN/THWN-2 8 AWG THHN/THWN-2 1 EMT <br />PAGE <br />REV: A2 10/23/2025 <br />ACXEL CALI <br />2437 S LOWELL ST, SANTA ANA, <br />CA, 92707 <br />PROJECT NUMBER: <br /> 109R-437CALI <br />SHEET <br />DESIGNER: <br />NITHYA L <br />CUSTOMER RESIDENCE: <br />TEL. (657) 324-1021 <br />APN: 140-153-21 <br />(415) 580-6920 ex3 <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603 <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46MODULE CHARACTERISTICS <br />SILFAB: SIL-440QD 440 W <br />OPEN CIRCUIT VOLTAGE 38.97 V <br />MAX POWER VOLTAGE 33.41 V <br />SHORT CIRCUIT CURRENT 14.29 A <br />INSTALLER MUST CHECK THE CONDITION, <br />INSTALLABILITY AND CODE COMPLIANCE OF <br />EXISTING EQUIPMENT. <br />General Notes: <br />GROUND - UFER, TWO GROUNDS RODS <br />OR COLD WATER GAS BOND <br /> SURGE PROTECTOR TO BE INSTALLED PER MANUFACTURER AND <br />PANEL BOARD SPECS. <br />IF THE RELOCATED LOADS EXTEND MORE THAN 6 FEET, AFCI PROTECTION <br />APPLIES PER 2019 CEC 210.12 <br />ANY MULTIWIRE BRANCH CIRCUITS RELOCATED ARE TO BE IDENTIFIED, GROUPED, <br />AND EQUIPPED WITH A 2-POLE OCPD BREAKER PER CEC 210.4(B,D).PV-4.1 <br />ELECTRICAL <br />CONT