My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2437 S Lowell St - Plan
PBA
>
Building
>
ProjectDox
>
L
>
Lowell St
>
2437 S Lowell St
>
2437 S Lowell St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/10/2025 5:00:09 AM
Creation date
12/10/2025 5:00:05 AM
Metadata
Fields
Template:
Plan
Permit Number
20187291
Full Address
2437 S Lowell St
Street Number
2437
Street Direction
S
Street Name
Lowell
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PAGE <br />REV: A2 10/23/2025 <br />ACXEL CALI <br />2437 S LOWELL ST, SANTA ANA, <br />CA, 92707 <br />PROJECT NUMBER: <br /> 109R-437CALI <br />SHEET <br />DESIGNER: <br />NITHYA L <br />CUSTOMER RESIDENCE: <br />TEL. (657) 324-1021 <br />APN: 140-153-21 <br />(415) 580-6920 ex3 <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603 <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />INVERTER CALCULATIONS <br />EACH INVERTER HAS THE FOLLOWING VALUES WHICH ARE CALCULATED FOLLOWING THESE FORMULAS: <br />INVERTER X: <br />{[((TEMP COEF VOC) X (VOC)) / 100] X (LOW TEMP - STC TEMP) + VOC} * (# MODULES / STRING) <br />INVERTER POWERWALL 3 1707000-XX-Y <br />INVERTER OVERCURRENT PROTECTION: <br /> (INVERTER(S) MAX COMBINED CURRENT) X (CONTINOUS LOAD) = <br /> 48 A X 1.25 = 60.0 A 100 A OVERCURRENT PROTECTION <br />ALLOWABLE BACKFEED: <br /> ALLOWABLE BACKFEED = (PANEL RATING) X 1.2 - (MAIN BREAKER RATING) = <br /> 225 A * 1.2 - 125 A = 145.0 A <br /> 100 A ≤ 145.0 A INTERCONNECTION <br /> MEETS CEC 2022 705.12(B)(3)(2) REQUIREMENTS <br />WIRE CALCULATIONS <br />WIRE AMPACITY CALCULATED FROM CEC 310.16/310.17 AS APPROPRIATE WITH AMBIENT TEMPERATURE CALCULATIONS FROM CEC 310.15(B)(1) <br />AND RACEWAY FILL ADJUSTMENTS FROM CEC 310.15(C)(1). CONDUIT ON THE ROOF SHALL BE INSTALLED NO LESS THAN 1" ABOVE THE ROOF <br />DECK. PV CIRCUIT CONDUCTOR AMPACITY IS CONSTRAINED USING THE 75°C COLUMN WITH THE CONTINUOUS DUTY UPRATING OR THE 90°C <br />COLUMN WITH THE RELEVANT AMBIENT TEMPERATURE AND RACEWAY FILL ADJUSTMENTS WITHOUT THE CONTINUOUS DUTY UPRATING PER <br />690.8(B), WHICHEVER IS THE LOWER VALUE WILL GOVERN CONDUCTOR SIZING. NON-PV CIRCUIT CONDUCTORS USE THE AMPACITY IN THE 75°C <br />COLUMN OR THE 90°C COLUMN WITH THE RELEVANT AMBIENT TEMPERATURE AND RACEWAY FILL ADJUSTMENTS, WHICHEVER IS LESS (110.14(C) <br />& 310.15(A)(2)). THE RATING OF THE CONDUCTOR AFTER ADJUSTMENTS SHALL BE GREATER THAN, OR EQUAL TO, THE CONTINUOUS DUTY <br />UPRATED CURRENT. <br />CALC EX: WIRE AMPACITY X AMBIENT TEMP. CORR. FACTOR X CONDUIT FILL ADJ. FACTOR >= OUTPUT CURRENT <br />ELECTRICAL <br />CALCS <br />PV-4.2
The URL can be used to link to this page
Your browser does not support the video tag.