November 14, 2012 SIGN COMPONENTS MANUAL (SAM) 50 <br />Power Grid, PX = Power White XL, PH = Power White HO, XH = Power White XL HO, MM = Mini Max; 'x' denotes design revision <br />number. <br />1. These products are only suitable for connection to a Class 2 power source. <br />2. When units are connected to a Class 2/"LPS" circuit, they are not to draw a total wattage of greater than the secondary or output <br />rating of the Class 2/"LPS" supply. <br />3. These products are suitable for use in dry, damp and wet locations. <br />4. These products described in this section may be cut into segments per manufacture insulation instructions. <br />5. Units may be provided with UYMR2,3M type VHB double-sided adhesive tape. Tape must be utilized per UYMR2 "Conditions of <br />Use" as defined in the Sign Components Manual. <br />6. The Light Guide has not been evaluated as an LED Strip Light enclosure or diffuser. Suitability shall be determined in the end <br />use product. <br />LED power supplies, Models GECLPS4. <br />1. LED power supply, Catalog No. GECLPS4 for dry and damp locations. <br />2. Each power supply output is Class 2. <br />LED power supplies, Models GECLPS4D. <br />1. LED power supply, Catalog No. GECLPS4D for dry and damp locations. <br />2. Each power supply output is Class 2. <br />LED power supplies, Models GECLPS6 and GECLPSPHA. <br />1. LED power supply, Catalog No. GECLPS6 for dry and damp locations. <br />' 2. Each power supply output is Class 2. <br />LED power supplies, Models GECLPS3. <br />1. LED power supply, Cat. No. GECLPS3 for dry and damp locations. <br />2. Each power supply output is Class 2. <br />LED power supplies, Models GECLPS5, GECLPSPH, GECLPSPW, GECLPSWH. <br />1. LED power supply, Cat. No. GECLPS5, GECLPSPH, GECLPSPW and GECLPSWH for dry and damp locations. <br />2. Each power supply output is Class 2. <br />Power supplies with Class 2 outputs, Models GEPS24-80, GEPS12-60, GEPS24-20. <br />1. These components are intended for use in dry locations only when not potted. When potted, they are suitable for damp <br />locations. <br />2. These power supplies need to be installed in an enclosure with a means for the connection to conduit. <br />3. When a Temperature Test is required of the power supply installed in an enclosure because the enclosure measures less than <br />13.5 by 6 by 4 inches, the maximum temperature on the output transformer by thermocouple is 110°C. Similarly, for Model <br />GEPS24-20, a temperature test is required when installed in an enclosure smaller than 13.5 by 6 by 4 inches, but the maximum <br />temperature on the output transformer by thermocouple is 90°C. <br />4. The output of these LED power supplies with Class 2 are acceptable for use in a damp and wet locations. <br />Power supplies with Class 2 outputs, Model GEXNPS30. <br />1. This component has outputs that qualify as being Class 2. <br />2. These components are intended for use in dry location only. <br />3. The transformer employs a Class B (130) Insulation System. <br />4. These components shall be installed in compliance with the enclosure and mounting requirements of the ultimate application. <br />5. The maximum room ambient temperature permitted by the manufacture is 50(C. <br />6. A Temperature Test is required of the power supply installed in an enclosure that measures less than 13.5 by 6 by 4 inches. The <br />maximum temperature on the output transformer by thermocouple is 110( C. <br />Power supplies with Class 2 outputs, Models GEPS24-180U, GE180/MVA/24T1-C <br />1. The maximum measured output voltage, current and power at the output of these models was found in compliance with the <br />limits for LPS output requirements and additionally evaluated to comply with Class 2 output criteria. <br />2. The transformer employ Class B insulation system. <br />3. Power Supply is intended for use in indoor Dry and Damp location only. <br />4. In the end product, power supply spacing to other heat producing components shall be minimum 2 inches spacing to sidewalls, <br />and minimum 2 inches spacing to top of enclosure. Adjacent power supplies shall be spaced at least 1 in. end to end and 4 in. in <br />any other direction. <br />5. Input and Output leads are style 1316, rated 600 V, 105°C, VW-1. Minimum No. 18 AWG. The suitability of input and output <br />connections shall be determined in each end use application. <br />6. The power supply was submitted and tested for a maximum manufacturer's recommended Tc point described in the table below. <br />If adjacent LED power supplies are spaced closer than 1 in. end to end or 4 in. side to side a temperature test shall be <br />conducted in the end use product. <br />Model Input Voltage, HZ Max. Case Temp @ Tc, °C Ambient, °C <br />GE180/MWV24T1-C, GEPS24-100-277, 60 80 60 <br />180U <br />LED Light Engine, Cat. Nos. 1110-WH-ZZ-TTK, 1110-RD-ZZ-TTK, catalog numbers where: "ZZ" representing assembly version: <br />followed by: "TT" - Optional - represents the color temperature of the LEDs in degree "K" Kelvin. Cat. Nos. 1111-XX-ZZ-Y-UK, <br />catalog numbers may vary per nomendature.: "XX" representing color: RD, RC, YG, GL, SB, BL, WH, YA, WW, GR, PO: "ZZ" <br />representing assembly version; "Y" representing number of LEDs; followed by: "TT" - Optional - represents the color temperature of <br />the LEDs in degree "K" Kelvin. <br />1. These products are only suitable for connection to a Class 2 power source. <br />2. When units are connected to a Class 2/"LPS" circuit, they are not to draw a total wattage of greater than the secondary or output <br />rating of the Class 2f'LPS" supply. <br />3. These products are suitable for use in dry, damp and wet locations. <br />4. The suitability of the LED Light Engine mounting means shall be determined in the end-use application. <br />5. The suitability of the LED Light Engine to be used without an additional electrical enclosure shall be determined in the end-use <br />application. <br />6. These products described in this section may be cut into segments per manufacture insulation instructions. <br />7. Units may be provided with UYMR2,3M type VHB double-sided adhesive tape. Tape must be utilized per UYMR2 "Conditions of <br />Use" as defined in the Sign Components Manual.