November 14,2012 SIGN COMPONENTS MANUAL (SAM) 58
<br />SUITE 6G
<br />2800 W SAHARA AVE
<br />LAS VEGAS, NV 89102
<br />LED Class 2 Strips, Models GL-RGB, GL-101, GL-105.
<br />1. These products are only suitable for connection to a Class 2 power source, rated 30 Volt DC or 15 Volt AC or less.
<br />2. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 voltage
<br />and energy limits and which is rated greater than 30 Volt DC or 15 Volt AC.
<br />3. These Class 2 LED modules are rated as noted in the model list table. When units are connected to a Class 2 circuit, they are
<br />not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply.
<br />4. These products are suitable for use in dry, damp and wet locations with supply sources rated Class 2.
<br />5. These products are not required to be enclosed or protected from the weather in the end product.
<br />Ratings:
<br />Model LED Strip Length Numberof LEDs Voltage Current Power
<br />GL-RGB 500mm 30 12 Vdc 0.2 A 2.4W
<br />GL-101 500mm 30 24 Vdc 0.3 A 7.2W
<br />GL-101 500mm 30 12 Vdc 0.6 A 7.2W
<br />GL-105 485mm 42 24 Vdc 0.36 A 8.6W
<br />GREEN LED MFG
<br />4127-D HOLLISTER
<br />E352678
<br />HOUSTON, TX 77080
<br />LED Class 2 Strips, Models KPL, PPL, DPL, OSPL, CPL, OCPL, KPLOAD, DPL(W), OSPL(W), KR3, K83,1<G3, KY3, DR3, DE33, DG3,
<br />DY3, KT\A/3, KTB3, KTR), DTV\/3, DTB3, DTR3, WPL, WPLO/\0, WR3, WB3, WG3, WSPL, NSR3, NSG3, NS83, NSR3, FPL, KGL,
<br />DGL, KR2, K82, KG2, DR2, 082, 062, DDL, KDLOAD, DDL(\/\4 KRDE KBD2, KGD2, KYD2, DRD2, DBD2, DGD2, DYD2, OSDLOAD,
<br />OSGL, OSDL, KPL4, DPL4, KPL40, DPL40, KPL400/V), DPL400/v), OSPL40, OSPL40(W), OSPL4, FPL40, KOL, DOL, KOR, DOR,
<br />KOB, DOB, KOG, DOG, DRGB3, WRGB3, WSRGB3, KRGB3, KSL, DSL, SSL, KSL(W), DSL(\/\4 KR1, KB1,1<Gl, DR1, DB1, DG1,
<br />NSR, NSG, NSB, DRGB2, SRG82, KRGBD, DRGBD, SRGBD, KRGB2, KRGB40, DRGB40, SRGB40, KPL6, DPLE, OSPL6.
<br />1. These products are only suitable for connection to a Class 2 power source rated 12 Volt DC or less.
<br />2. These products are intended for use only when connected to a power source that complies with Class 2 voltage and energy
<br />limited circuit and is rated greater than 12 V DC.
<br />3. When these units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondar'y or output
<br />rating of the Class 2 supply.
<br />4. These products are suitable for use in dry, damp and wet locations with supply sources rated at 12 Volts DC or less.
<br />5. These products are not required to be enclosed or protected from the weather in the end product.
<br />6. These products may be secured in place in the end product by any means available.
<br />GRIMCO INC
<br />1585 FENCORP DR
<br />E350828
<br />FENTON, MO 63026
<br />Class 2 LED Module, Cat. No. H2.
<br />1. These products are only suitable for connection to a Class 2 power source rated 12 Volt DC or less.
<br />2. These products are intended for use only when connected to a power source that complies with Class 2 voltage and energy
<br />limited circuit and is rated greater than 15V DC.
<br />3. These products are each rated max. 1.5 watts per module. When units are connected to a Class 2 circuit, they are not to draw a
<br />total wattage of greater than the secondary or output rating of the Class 2 supply.
<br />4. These products are suitable for use in dry, damp and wet locations with supply sources rated at 12 Volts DC or less.
<br />5. These products are not required to be enclosed or protected from the weather in the end product.
<br />6. These products may be secured in place in the end product by any means.
<br />Structural Panel, non-electrical enclosure rated for use in electric sign components, Cat. No. MAX-Metal, MAX-Metal XL,
<br />and MAX-Metal HD.
<br />1. Illustrate the proper cutting, pointing, installation, component securement and securement to a building surface of a structural
<br />panel.
<br />2. Structural panels have been evaluated for wet location with 50°C ambient.
<br />3. Structural panels may be employed as external decorative faces and are acceptable for support of complete electrical
<br />enclosures, plastic faces, and moldings that are reliably secured to the panel.
<br />4. Structural panels are not suitable to be used as the enclosure of bare live parts or wiring.
<br />5. Nuts and bolts must be used when fastening a ballast or transformer weighing more than 7-1/2 lbs (3.4 kg).
<br />6. A letter made from a structural panel shall have at least two points of support and shall have no point more than 10 in. from a
<br />point of support.
<br />7. These panels shall be attached with screws, bolts or rivets to the structural framework so as to cause bonding to both
<br />conductive surfaces to ground, and to adequately secure each panel in place.
<br />GUANGZHOU FANGCUN HONGMEI NEON EQUIPMENT FACTORY E333976
<br />1-3 PANLONG INDUSTRIAL AREA
<br />LONGXI RD LIWAN
<br />GUANGZHOU, GUANGDONG 510378 CHINA
<br />Class 2 LED Drivers, Model Nos. HMA-60NU-R12, HMA-30NU-R12, HMA-240NU-RX, HMA-200NU-RX, HMA-150NU-RX, HMA-
<br />120NU-RX, HIVIA-100NU-RX, HMA-90NU-RX, HMA-60NU-RX, HMA-45NU-RX, HMA-50NU-RX, HMA-350NU-RX, HMA-700NU-
<br />RX, HMA-1050NU-RX, HMA-1400NU-RX, HMA-520NU-RX, HMA-20NU-RX, HMA-15NU-RX, HMA-12NU-RX, HMA-10NU-RX,
|