Laserfiche WebLink
59 SIGN COMPONENTS MANUAL (SAM)November 14, 2012 <br />HMA-8NU-RX, HMA-6NU-RX, HME-45N-R12, HME-60N-R12, HME-20N-R24, HME-35N-R24, HME-45N-R24, HME-60N-R24, <br />HMT-YZ-RX, HME-100N-R12, HME-20N-R12, HME-35N-R12. <br />1. The output of this component complies with Class 2 requirements in the Standard for Class 2 Power Units, UL 1310. <br />2. In the end product, power supply spacing to other heat producing components shall be min. 2 inches spacing to sidewalls, and <br />min. 2 inches spacing to top of enclosure. <br />3. These products shall be enclosed in the end product. <br />4. These power supplies are suitable for use in dry and damp locations. <br />5. These devices are intended for factory installation only. <br />6. This Class 2 power supply is not provided with any grounding. The enclosure must be grounded in the end product. <br />LED Modules, Cat. No. HM-FXXQYZTMMMM series, where XX maybe replaced with the number 12; Q may be replaced with <br />SMD or FLUX; Y may be replaced with 20 mm, 30 mm 48 mm, 55 mm, 62 mm or 95 mm, Z may be replaced with R, Y, G, W or <br />RGB, T may be replaced with the numbers 2,3 and 4. <br />1. These products are only suitable for use in dry, damp and wet locations and supplied with a Class 2 power source rated 12 Volt <br />DC or less. <br />2. When units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output rating <br />of the Class 2 supply. <br />3. These products are not required to be enclosed or protected from the weather in the end product. <br />4. These products may be secured in place in the end product by any means available. <br />HANKSCRAFT INC E343966 <br />300 WENGEL DR <br />PO BOX 190 <br />REEDSBURG, WI 53959 <br />LED Modules, SCLM Series. <br />1. These products are only suitable for connection to a Class 2 power source, rated 12 Volt DC or less. <br />2. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 voltage <br />and energy limits and which is rated greater than 15 V. <br />3. These Class 2 LED modules are each rated as noted in the model list tables. When units are connected to a Class 2 circuit, they <br />are not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply. <br />4. These products are suitable for use in dry, damp and wet locations with supply sources rated at 12 Vdc or less. <br />5. These products are not required to be enclosed or protected from the weather in the end product. <br />HANKSCRAFTINC <br />300 WENGEL DR <br />PO BOX 190 <br />REEDSBURG, WI 53959 <br />Class 2 LED System, designated as "INDOOR MENU BOX W/ LED SYSTEM". <br />1. These products should be installed in accordance with the manufacturer's instructions. <br />2. The Class 2 load side of these products is suitable for use in dry and damp locations. <br />3. The suitability of enclosure of these products shall be determined in the end product. <br />4. The need for conducting temperature test shall be determined in the end product applications. <br />5. The mounting means of these products shall be determined in the end product applications. <br />6. The suitability of the LED driver (power supply) shall be determined in the end use. <br />E344153 <br />HATO LIGHTING B V <br />HANDELSSTRAAT 31 <br />E356565 <br />6135 KK SITTARD, THE NETHERLANDS <br />Class 2 LED Module, Cat. No. EUL-Fixt-XXXX-XXXX-XX-XXX; "EUL" stands for the productname "EcoUnlimitLED"; "Fixt" stands <br />for a Fixt-Length; The first four X are Arabic numerals from 200 up to 2800, these indicate the fixt-length in cm; The second four X <br />are Arabic numerals 4250 (+/-250) or 6500 (+/-500), these indicate the Correlated Color Temperature (CCT) in Kelvin; The two X <br />indicate the number of segments per side. Any Arabic number from 1 up to 14 segments per side; The last three X are Arabic <br />numerals and indicate the nominal power of the design. <br />1. These products shall only be used in an End-enclosure for Dry and Damp Locations Only. <br />2. These products shall only be connected to a Class 2 power source or LPS power source, rated max. 4.17 Amps, 24 Volt DC <br />with a maximum power limit of 100 VA. <br />3. Each model is allowed to contain a maximum of 14 segments, as detailed in the mounting instructions. <br />4. The suitability of leads shall be evaluated in end product use. <br />5. The need to perform an input test and a temperature test shall be evaluated in end product use. <br />HEARTLAND LIGHTING L L C, DBA EMERALIGHT E248921 <br />11470 BAKER RD <br />PLATTE CITY, MO 64079 <br />Aluminum reinforced sign face trim, Cat. Designations SnakeEye, SideWinder, DiamondBack, Trinity, T2, Glory 1, Glory 11, and <br />PowerHouse. <br />1. The number and arrangement of the LED boards connected to a Class 2 power supply shall not exceed the output <br />wattage/current rating of the power supply. Each LED board is rated as follows: <br />Watt/ma usage for each color <br />Modd Volage·OC \AN al Gn Red Amb <br />SnakeEye 12 0542 ----