November 14,2012 SIGN COMPONENTS MANUAL (SAM) 74
<br />3. These products are suitable for use in dry, damp and wet locations.
<br />4. These products are not required to be enclosed or protected from the weather in the end product.
<br />5. When these products are used in applications other than signs or outline lighting, the need to conduct a temperature test shall
<br />be considered.
<br />Class 2 Power Supply, Cat. Nos. MJ-ABCD-WXYZ Series, where AB is 12 and CD-WXYZ is 20-1670,40-3300 or 60-5000..
<br />1. These power supplies have a maximum of one Class 2 outputs. The output of these power supplies have been evaluated to
<br />Class 2 output requirements for dc circuits.
<br />2. These products with Class 2 outputs are suitable for use in dry and damp locations only.
<br />3. In the end product, power supply spacing to other heat producing components shall be minimum 2 inches spacing to
<br />sidewalls, and minimum 2 inches spacing to top of enclosure.
<br />4. These products have not been subjected to Leakage Current, Strain Relief, and Impact Tests. The need to conduct these tests
<br />shall be considered in the product. In addition to these tests, the need to conduct the Mold Stress test on model MJ-1260-500
<br />shall be considered in the end product.
<br />5. These products shall be provided with additional endosure when used in the end product.
<br />Class 2 LEDs, Cat. Nos. Cat. Nos. JE-001X (HS-F504BR4TN), JE-002X (HS-F504BN4TN), JE-003X (HS-F504884TN), JE-004X,
<br />JE-005X (HS-F504BY4TN), JE-006X (HS-R483AR4CY or HS-R484CN4CY or HS-R484CB4CY), where X may be replaced with A,
<br />B, G, M, R or W.
<br />1 These products are only suitable for connection to a Class 2 power source, rated 15 Volt (DC or AC) or less.
<br />2. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 voltage
<br />and energy limited circuit.
<br />3. When units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output
<br />rating of the Class 2 supply.
<br />4. These products are suitable for use in dry, damp and wet locations.
<br />5. These products are not required to be endosed or protected from the weather in the end product.
<br />Class 2 LED Controllers, Models HM-12RGB5A3-RC, HM-12RGB5A3-XY Series, where suffix X and Y may be any alphanumeric
<br />characters.
<br />1. These products are only suitable for connection to the output of a UL Listed or R/C Class 2 Power Supply rated max 24VDC.
<br />2. These products are rated per the Table below. When units are conneded to a Class 2 circuit, their ratings are to be limited to
<br />draw a total wattage of no greater than the secondary current rating of each Class 2 power supply.
<br />Model Input - Class 2 Output - Class 2
<br />HM-12RGB5A3-XY Series 12 - 24 Vdc 10-24V 24 W
<br />3. These products are suitable for use in dry, and damp.
<br />4. These products are each rated max. 24 watts. When units are connected to a Class 2 circuit, they are not to draw a total
<br />wattage of greater than the secondary or output rating of the Class 2 supply.
<br />JUSTIN INC E235322
<br />2663 N LEE AVE
<br />SOUTH EL MONTE, CA 91733
<br />Class 2 Power Supply, Model 601-12DC, 601-12DCR, 101-24DCR, C2240-12DCR, C2240-24DCR, C2240-12, C2240-12-240,
<br />C2240-24, and C2240-24-240.
<br />1. These power supplies have been evaluated for use in LED signs.
<br />2. The power supplies have outputs that individually comply with Class 2 circuit requirements.
<br />3. These units are suitable for use in dry and damp locations without a need for an additional enclosure.
<br />4. The output of this power source shall not be connected to any other power source or provide power to components connected
<br />to another power source.
<br />5. These products shall have conductors entering, leaving or residing in the wiring compartment or junction box extending at
<br />least 150 mm (6 in) inside.
<br />Class 2 Power Supply, Model 601-12DC-LC, 601-12DCR-LC, 101-24DCR-LC, C2240-12DCR-LC, C2240-24DCR-LC, C2240-12-
<br />LC, C2240-12-240-LC, C2240-24-LC,and C2240-24-240-LC.
<br />1. These power supplies have been evaluated for use in portable LED signs.
<br />2. The power supplies have outputs that individually comply with Class 2 circuit requirements.
<br />3. These units are suitable for use in dry and damp locations without a need for an additional enclosure.
<br />4. The output of this power source shall not be connected to any other power source or provide power to components connected
<br />to another power source.
<br />5. The attachment plug on the end of the power supply cord is not to be removed.
<br />KBJ SIGN INC
<br />1800 W ADAMS BLVD
<br />E350092
<br />LOS ANGELES, CA 90018
<br />Class 2 LED Modules, KPL, FPL, KR3.
<br />1. These products are only suitable for connection to a Class 2 power source rated 12 Volt DC or less.
<br />2. These products are intended for use only when connected to a power source that complies with Class 2 voltage and energy
<br />limited drcuit and is rated greater than 12 V DC.
<br />3. When these units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output
<br />rating of the Class 2 supply.
<br />4. These products are suitable for use in dry, damp and wet locations with supply sources rated at 12 Volts DC or less.
<br />5. These products are not required to be enclosed or protected from the weather in the end product.
<br />6. These products may be secured in place in the end product by any means available.
<br />KEYSTONE TECHNOLOGIES LLC E356111
|