My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10179314_2800 N. MAIN 1048 - Plan (2)
PBA
>
Building
>
Plans
>
M
>
Main St
>
2800 N Main St Unit# 1048
>
10179314_2800 N. MAIN 1048 - Plan (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2024 2:06:05 AM
Creation date
10/25/2020 9:43:29 PM
Metadata
Fields
Template:
Plan
Permit Number
10179314
Full Address
2800 N Main St Unit# 1048
Fully Linked
True
Document Relationships
10179314 - Permit
(Permit - Plan)
Path:
\Building\Permits\M\Main St\2800 N Main St Unit# 1048
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
93 SIGN COMPONENTS MANUAL (SAM)June 19, 2013 <br />N GLANTZ & SON E352418 <br />2501 CONSTANT COMMENT PL <br />LOUISVILLE, KY 40299 <br />Structural panels, Models EMPB30, EMPB31 L. <br />1. The structural panel is suitable for use in dry, damp and wet locations. <br />2. The structural panel may be used in decorative and sign body applications, and shall not be used as part of the sign enclosure. <br />3. The panel is not suitable for use in component mounting and support applications. <br />4. Rain tightness shall be determined in the end product. <br />5. Electrical spacing and bonding for grounding shall comply with the end product standard. <br />6. Not suitable for use in terminating conduit. <br />7. Any parts other than neon standoffs or small decorative parts secured to the panel must be secured by means of through bolts, <br />nuts and washers. The minimum washer diameter is 7/16 in. <br />8. A letter made from a structural panel shall have at least two points of support and shall have no point more than 10 in. from a <br />point of support. <br />9. The structural panels are rated 75°C, where consideration will need to be given to end product thermal spacing from heat <br />producing components. <br />10. These materials are available as unpainted aluminum or pre-painted aluminum. <br />11. This material has not been investigated for the securement of conduit, electrode housings or the like, suitability shall be <br />determined in the end product. <br />NANJING CEDAR GREEN TECHNOLOGIES CO LTD <br />739 SHENGAN AVENUEY <br />BINJIANG DEVELOPMENT AREA <br />JIANGNING DISTRICT <br />E358556 <br />NANJING, JIANGSU CHINA <br />Class 2 LED modules, Cat. No. CD-MXX-XXX-XX-XX-XXX series. The first X can be any one of the Arabic numerals of 1 through <br />9, these indicate LED quantity; The second X can be any letter in alphabet, represent for beam angel The third X is for the supplier <br />of the lamp; The fourth X is for the model of the lamp; The fifth X can be any one of alphanumeric characters; The sixth and <br />seventh X is for the color; The eighth and ninth X is for the product versions; The last three X are for the input voltage, 12V <br />represent the input voltage is 12VDC, 15V represent the input voltage is 15VDC. <br />1. These products are only suitable for connection to a Class 2 power source, rated 15 Volt DC or less. (For model CD- MXX-XXX- <br />XX-XX-15\/9 <br />2. These products are only suitable for connection to a Class 2 power source, rated 12 Volt DC or less. (For model CD- MXX-XXX- <br />XX-XX-12\4 <br />3. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 voltage <br />and energy limits and which is rated greater than electrical ratings. <br />4. When units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output rating <br />of the Class 2 supply. <br />5. These products are suitable for use in dry, damp and wet locations with supply sources rated at 15 Vdc or less. (For model CD- <br />MXX-XXX-XX-XX-15\0 <br />6. These products are suitable for use in dry, damp and wet locations with supply sources rated at 12 Vdc or less. (For model CD- <br />MXX-XXX-XX-XX-12\0 <br />7. These products are not required to be enclosed or protected from the weather in the end product. <br />8. The suitability of supply leads shall be determined in end use. <br />NANOLUMENS INC <br />4900 AVALON RIDGE PKY <br />NORCROSS, GA 30071 <br />Component Signs, Models NS-521, NS-600, NS-625. <br />1. These components should be installed in accordance with the manufacturer's installation instructions. <br />2. These products are suitable for use in dry locations. <br />3. Each power supply can only drive max number of 15 modules. <br />4. These units are rated as follows; <br />E348993 <br />1 Input Output Per Power Supply <br />Input Voltage Max. Input Current Input Frequency Output Voltage Max. Output Current <br />Model Designation (Vac) (A) (Hz)(Vdc) (A) <br />NS-521, NS-600, NS-625 120-240 5-2.5 50/60 5 60 <br />5. These products shall be enclosed in a suitable electric enclosure in the end product. <br />6. When provided with attachment plug, this product shall be connected to a dedicated receptacle in a permanently connected <br />sign. <br />7. These products are suitable for factory installation only. <br />NC LED CO LTD <br />16-17 GAGOK-RI <br />HWADO-EUP <br />NAMYANGJU-SI, GYEONGGI-DO 472-841 REPUBLIC OF KOREA <br />E347462
The URL can be used to link to this page
Your browser does not support the video tag.