My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10179402_2800 N. MAIN #247 - Plan (2)
PBA
>
Building
>
Plans
>
M
>
Main St
>
2800 N Main St Unit# 247
>
10179402_2800 N. MAIN #247 - Plan (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/19/2021 1:41:30 AM
Creation date
10/25/2020 9:44:08 PM
Metadata
Fields
Template:
Plan
Permit Number
10179402
Full Address
2800 N Main St Unit# 247
Fully Linked
True
Document Relationships
10179402 - Permit
(Permit - Plan)
Path:
\Building\Permits\M\Main St\2800 N Main St Unit# 247
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
June 19, 2013 SIGN COMPONENTS MANUAL (SAM)126 <br />Class 2 LED Module, Cat. No. 701946-XXYYYYYYZZZ series, where XX, YYYYYY and ZZZ may be replaced with any <br />alphanumeric characters or blank. <br />1. These products are suitable for use in dry, damp and wet locations and supplied only with a Class 2 power source rated 24 Volt <br />DC or less. <br />2. When units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output rating <br />of the Class 2 supply. <br />3. These products are not required to be enclosed or protected from the weather in the end product. <br />4. These products may be secured in place in the end product by any means available. <br />Class 2 power supply, Model 701285. <br />1. Power supply is intended to power LEDs in signs. <br />2. Power supply model is intended for permanent connection only. <br />3. These units are suitable for use in dry location without a need for an additional enclosure and in damp locations when installed <br />inside a sign that complies with the Exclusion of Water Test in UL 48. <br />4. If the power supply output wiring is extended longer than the 5 foot leads provided, the spliced connections shall be made <br />inside a Listed junction box suitable for the application included with proper grounding. <br />Class 2 power supply, Cat. Nos. 701349, 701351. <br />1. Power supply models 701349 and 701351 are intended to power LEDs in signs. <br />2. Power supply model 701349 and 701351 are intended for permanent connection only. <br />3. These units are suitable for use in dry location without a need for an additional enclosure and in damp locations when installed <br />inside a sign that complies with the Exclusion of Water Test in UL 48. <br />5. These power supplies have two outputs. The Class 2 output circuits are not to be conductively connected to each other in the <br />sign by wiring or other type of component. <br />6. The maximum rated output power for Model 701349 is 42 watts at each Class 2 output. The maximum rated output power for <br />Model 701351 is 60 watts at each Class 2 output. <br />Class 2 power supplies, Models 701507-MOD, 701507-MOD277 (AD060S277/347-SLN). All may be followed by alphanumeric <br />suffix. <br />1. These power supplies have a maximum of one Class 2 output. The output of these power supplies has been evaluated to Class <br />2 output requirements for dc circuits. <br />2. These products with Class 2 outputs are suitable for use in dry, damp and wet locations. <br />3. In the end product, power supply spacing to other heat producing components shall be minimum 4 inches spacing to sidewalls, <br />and minimum 2 inches spacing to top of enclosure. <br />4. When used in wet locations, each unit shall be provided with Listed (QCRV) 1/2 inch, liquid tight conduit fittings on primary <br />circuit. <br />5. When used in a cord connected product, the need for conducting a leakage current test shall be considered in the end product. <br />6. When not marked for Dry and Damp Locations Only the power supply primary bracket shall be provided with min. 3.5 threads <br />and maximum 5 threads tapered for connection to liquid tight conduit fitting. If less than 3.5 threads, the liquid tight shall be <br />provided with watertight fitting Listed (QCRV) 1/2 inch, liquid tight conduit fittings. <br />7. The suitability of grounding connection shall be determined in the end-use product. <br />Class 2 power supply, Model 701680. <br />1. The product shall be installed in compliance with the mounting, spacing, casualty, and segregation requirements of the ultimate <br />application. <br />2. These units are provided with a Class 105(A) insulation system. <br />3. The suitability of the input and output connections shall be determined in each end use application. <br />4. These power units are intended for dry or damp location use only. <br />5. Strain Relief on input lead construction and Impact Tests have not been investigated. <br />6. The polymeric enclosure of each unit has not been evaluated as ultimate enclosure. The flame class of polymeric enclosure of <br />each unit is V-2, and the necessity of additional fire barriers shall be determined in end product. <br />7. Multiple power supplies shall be spaced at least 25mm (1 in.) end to end or 102mm (4 in.) in other directions. If lesser spacings <br />are used, then the Temperature Test shall be conducted in the end use product. For reference the maximum enclosure (case) <br />temperature on the power supply was 90°C when tested at 58.4° ambient. <br />Class 2 power supply, Model 701680-MW. <br />1. These power supplies have been evaluated to Class 2 output requirements for dc circuits with a maximum of one Class 2 <br />output. <br />2. The load powered by the Class 2 output of the power supplies rated at max 30 VDC or less are suitable for use in dry, damp and <br />wet locations. <br />3. In the end product, power supply spacing to other heat producing components shall be minimum 2 inches spacing to sidewalls, <br />and minimum 2 inches spacing to top of enclosure. <br />4. These products are provided with the following electrical ratings: <br />1 Input Output <br />Model Vac A Hz Vdc A <br />]701680-MW 100-240 0.55 50/60 12 1.67 <br />5. These products shall be enclosed in the end product. <br />6. These power supplies are suitable for use in dry and damp locations. <br />Class 2 power supply, Model 701681. <br />1. The product shall be installed in compliance with the mounting, spacing, casualty, and segregation requirements of the ultimate <br />application. <br />2. These units are provided with a Class 105(A) insulation system. <br />3. Input leads are Style 1015, No. 18 AWG, rated VW-1,600 V, 105°C. Output leads are Style 1430, No. 18 AWG, rated VW-1, <br />300 V, 105°C. The suitability of the input and output connections shall be determined in each end use application. <br />4. These power units are intended for dry or damp location use only. <br />5. Strain Relief and Impact Tests have not been investigated on input lead construction. The suitability of the enclosure as ultimate <br />enclosure shall be determined in the end-use application. <br />6. The polymeric enclosure of each unit has not been evaluated as ultimate enclosure. The flame class of the polymeric enclosure <br />is V-0 and the necessity of additional fire barriers shall be determined in end product.
The URL can be used to link to this page
Your browser does not support the video tag.