127 SIGN COMPONENTS MANUAL (SAM)June 19, 2013
<br />7. In the end product, power supply spacing to other heat producing components shall be minimum 2 inches spacing to sidewalls,
<br />and minimum 2 inches spacing to top of enclosure.
<br />Class 2 power supplies, Model 701495.
<br />1. These power supplies have been evaluated to Class 2 output requirements for dc circuits with a maximum of four Class 2
<br />outputs.
<br />2. These power supplies are only suitable for use in dry, damp and wet locations.
<br />3. In the end product, power supply spacing to other heat producing components shall be minimum 2 inches spacing to sidewalls,
<br />and minimum 2 inches spacing to top of enclosure.
<br />Class 2 power LED Lighting Strip, 701912-QQXXYYZZZ series, where QQ represents length, XX represents the LED color
<br />temperature, YY represents configuration and ZZZ represents the LED drive current.
<br />1. These products are only suitable for connection to a Class 2 power source, rated 24VDC.
<br />2. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 voltage
<br />and energy limits and which is rated greater than 24VDC.
<br />3. When units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output rating
<br />of the Class 2 supply.
<br />4. These products are suitable for use in dry, damp and wet locations with supply sources rated class 2.
<br />5. These products are not required to be enclosed or protected from the weather in the end product.
<br />6. These products may be secured in place in the end product by any means available.
<br />7. When these products are used in applications other than signs or outline lighting, the need to conduct a temperature test shall
<br />be considered.
<br />Class 2 "Dimming Control Knob" potentiometer, Model 701843.
<br />1. These products are only suitable for connection to the output of a UL Listed or Recognized Class 2 power supply rated max 12
<br />VDC.
<br />2. These products are suitable for use in dry and damp locations.
<br />3. These products are suitable for factory wiring only.
<br />4. These products are 1 Kohm potentiometers intended for connection to max 12 VDC Class 2 power supply that drops the voltage
<br />to a 0-10 V signal to feed into the PWM dimmer.
<br />Class 2 LED Modules, Cat. No. 701960-XXYYYZ Series, where XX, YYY, and Z may be replaced with any alphanumeric
<br />character or blank.
<br />1. These products are suitable for use in dry, damp and wet locations and supplied only with a Class 2 power source rated 24 Volt
<br />DC or less.
<br />2. When units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output rating
<br />of the Class 2 supply.
<br />3. These products are not required to be enclosed or protected from the weather in the end product.
<br />4. These products may be secured in place in the end product by any means available.
<br />SPARTECH PLASTICS
<br />3454 N DETROIT ST
<br />E202184
<br />WARSAW, IN 46580
<br />Rigid sign enclosure systems, designated SunGard, Sungard Plus, PC-2000, DuraGard and PC-2000 Plus.
<br />1. These materials are acceptable for applications of sign enclosures, sign bodies, and decorative parts. For enclosure
<br />applications, these materials may be located no closer than 0.8 mm to any uninsulated live part.
<br />2. The materials, SunGard, PC-2000,or DuraGard and PC-2000 Plus, have a use temperature of 80C. If a heat producing
<br />Component such as electrode, transformer or ballast is located within 1 inch of the material, a temperature test should be
<br />conducted in the end product.
<br />3. The material, SunGard Plus, has a rated temperature index (RTI) of 105°C, and therefore, is suitable for direct contact with and
<br />mounting to heat producing component such as transformers, power supplies, and ballasts in the end product.
<br />4. Marking - The following markings or equivalent shall be provided. Markings A and B below shall be marked anywhere where
<br />readily visible during servicing.
<br />A. "Do not attempt to repair or service a damaged sign face. For servicing of this sign, contact ."(Blank to be
<br />replaced by Applicant's Company name, City and State.)
<br />B. "Replace only with , Type ." (Blanks to be replaced by Applicant's Company name and material Type or
<br />designation.)
<br />5. The SunGard and SunGard Plus are suitable for use as an enclosure of an indoor or outdoor sign and has been evaluated for
<br />UV exposure. The PC-2000,or DuraGard or PC-2000 Plus are suitable only for use as an enclosure for indoor signs.
<br />6. All materials must be a minimum of 0.10 in. (2.54 mm) thick to comply as a sign enclosure. All testing should be repeated if the
<br />thickness of the sheet is reduced to less than 0.10 in.
<br />7. All materials have been investigated for and comply with the termination of conduit, electrode housings or the like.
<br />8. All materials have been approved for component support.
<br />9. The suitability of the securement system for the SunGard and Sungard Plus materials to prevent the entrance of water, which
<br />may contact live parts within a sign in outdoor sign applications, shall be determined.
<br />10. When the material is relied upon for the mounting of the sign and/or sign components, the material shall be subjected to the
<br />mounting means test in the end product.
<br />11. A marking shall be provided inside the sign indicating that servicing or replacement of the sign face material must be done by
<br />the company which sold the sign.
<br />12. Only one side of the Sungard or SunGard Plus plastic sheets are UV coated. Therefore, the UV coated side shall be placed
<br />such that it is the exterior surface of the sign.
<br />13. Testing for exposure to live parts was conducted on the non-UV *coated side of the Sungard and Sungard Plus plastics. Thus,
<br />the non-UV coated side shall be the only side exposed to live parts.
<br />14. The mounting system must secure the sign face to the enclosure in such a way that the edges of the sign face are not exposed
<br />to the interior of the sign. This may be accomplished with channels, flanges or other suitable mechanical means.
<br />Rigid non-enclosure sign face, systems for use in electric signs, designated: R59(1). May be followed by up to five numbers
<br />and/or letters to indicate color.
|