Laserfiche WebLink
2% <br />G <br />W CW CWCWCWCW <br />SS SSSSSSSSSS <br />GAS GASGASGASGAS <br />2% <br />2% <br />2% <br />5% <br />5% <br />2%2% <br />2%2%2% <br />5% <br />2% <br />2% <br />2% <br />2% <br />5% <br />2% <br />2% <br />2% <br />5%5% <br />5% <br />2% <br />F. <br />S <br />. <br />L <br />F. <br />S <br />. <br />L <br />F. <br />S <br />. <br />L <br />F. <br />S <br />. <br />L <br />F. <br />S <br />. <br />L <br />2% <br />CW CWCWCWCWCWCWCWCWCW <br />CW <br />CW <br />CW <br />CW <br />CW <br />SS <br />SS <br />SS <br />SSSSSSSSSSSS <br />DRAINAGE DIRECTION AND SLOPE <br />PROPERTY LINE CORNER POINTS <br />AND ELEVATION DATUM <br />#KEYNOTE CALLOUTS <br />EXISTING WALL TO <br />REMAIN AND NEW WALL <br />WALL TO BE DEMOLISHEDFIRE SEPARATION IMAGINARY LINEF.S.L <br />FIRE SEPARATION DISTANCEF.S.D <br />JURISDICTION HAVING AUTHORITY:SANTA ANA, CA 92703 <br />LEGAL DESCRIPTION:N-TRACT: 4659 BLOCK, LOT 28 <br />ASSESSORS PARCEL NO. APN:010-011-39 <br />IN FLOOD ZONE FEMA SHFA'S:TYPE X <br />CONSTRUCTION TYPE:V-B (NON-RATED) <br />ZONING:R-1 <br />OCCUPANCY GROUP:R3 <br />SPRINKLERS:NO (MAINHOUSE & ADU) <br />NUMBER OF STORIES:1-STORY (ALLOWABLE: 27 FT) <br />REQUIRED SETBACKS FOR ADU <br />FRONT SETBACK 20 FT <br />SIDE SETBACK 4 FT <br />REAR SETBACK 4 FT <br />LOT SIZE: 6,100 SF <br />EXISTING AREA: <br />1.EXISTING MAINHOUSE: <br />-(E) LIVING: 1,374 SF <br />-(E) PORCH:201 SF <br />-(E) GARAGE :457 SF <br /> (E) MAN HOUSE AREA: 2,032 SF <br />NEW AREA: <br />1.NEW DETACHED ADU-1STORY: <br />-(N) LIVING: 749 SF <br />-(N) ENTRY PORCH: 51 SF <br /> ADU TOTAL AREA: 800 SF <br />LOT COVERAGE: <br />(1,347 + 457)X100% /6,100 = 29.6 % (<35%) <br />TOTAL AREA OF YARD FRONT PROVIDE: 20'-10''x 61'-0'' = 1,331 SF <br />LANSDSCAPE OF FRONT YARD REQUIREMENT: 65% MIN <br />LANDSCAPE AREA OF FRONT YARD: 720+ 153= 873 SF <br />LANSDSCAPE OF FRONT YARD PROVIDE: <br />(873/1,331)x100 % = 65.6 % (>65 %) <br />PERMEABLE HARDSCAPE AREA OF FRONT YARD REQUIREMENT: 35% MAX <br />HARDSCAPE AREA OF FRONT YARD: 458 SF <br />PERMEABLE HARDSCAPE AREA OF FRONT YARD PROVIDE: <br />(458/1,331)x100%= 34.4% (<35%) <br />PARKING REQUIRED: <br />(E) MAINHOUSE: 4 STALLS <br />(N) ADU: 0 STALLS <br />TOTAL: 4 STALLS <br />PARKING PROVIDED: <br />(E) MAINHOUSE : 4 STALLS -2 OPEN SPACE (10'X20'') & 2CAR-GARAGE <br />(N) ADU: 0 STALLS <br />TOTAL: 4 STALLS <br />(THE ACCESSORY DWELLING UNIT IS LOCATED WITHIN <br />ONE-HALF MILE WALKING DISTANCE OF PUBLIC TRANSIT. <br />NO ADDITIONAL PARKING SPACE REQUIRED) <br />1. DEMOLITION CONTRACTOR SHALL RELOCATE REUSABLE MATERIALS TO DESIGNATED SALVAGE AREA, NON-USABLE MATERIALS SHALL BE PLACED APPROPRIATELY IN REFUSE BIN <br />AND SHALL BE COVERED AT NIGHT AND DURING RELATIVE HIGH WINDS, RAIN, ETC...REFUSE BIN SHALL BE COVERED DURING TRANSFER TO AND FROM DUMP SITE. CONTRACTOR <br />TO BE LIABLE FOR REFUSE SPILLING. ALL DEBRIS TO BE HAULED AWAY AND CLEAN-UP SHALL BE COMPLETED TO BROOM FINISH. EXISTING MATERIALS AND/OR STRUCTURE TO <br />REMAIN SHALL BE PROTECTED FROM DUST, PAINT CHIPPING, ETC..., BY USE OF PLASTIC OR WHATEVER IS REQUIRED FOR PROPER PROTECTION. EXISTING STRUCTURES SHALL <br />HAVE BRACING AND SHORING AS REQUIRED TO PROTECT THE EXISTING STRUCTURE. PROVIDE DE-WATERING FACILITIES FOR CONSTRUCTION AS REQUIRED. COORDINATE AS-BUILT <br />INFORMATION, STRUCTURAL, ETC. TO DESIGNER/ENGINEER AS REQUIRED. <br />2. THE DISCHARGE OF POLLUTANTS TO ANY STORM DRAINAGE SYSTEM IS PROHIBITED. NO SOID WASTE, PETROLEUM BYPRODUCTS, SOIL PARTICULATE, CONSTRUCTION WASTE <br />MATERIALS, OR WASTEWATER GENERATED ON CONSTRUCTION SITES OR BY CONSTRUCTION ACTIVITIES SHALL BE PLACED, CONVEYED OR DISCHARGED INTO THE STREET, GUTTER <br />OR STORM DRAIN SYSTEM. <br />3. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOTCLEAR AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, <br />PULLBOXES,TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC.) OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN <br />FEET OF ANY POWER LINES WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL <br />EXPENSES. <br />4. WHEN UTILITIES METER ALTERATION / RELOCATION OCCUR, INSTALLATION PROCEDURES SHALL BE VERIFIED AND APPROVED BY THE BUILDING INSPECTOR PRIOR TO <br />INSTALLATION. <br />5. NOTIFY AQMD FOR ASBESTOS REMOVAL PROCEDURE AND SUBMIT ASBESTOS REPORT TO BUILDING DIVISION PRIOR TO DEMOLITION PERMIT ISSUANCE. <br />6. ALL CONSTRUCTION WASTE AND DEBRIS MUST BE CONTAINERIZERD AT ALL TIMES. <br />7. DUST CONTROL MEASURES SHALL BE MAINTAINED THROUGHOUT THE DURATION OF THE PROJECT. <br />8. NEW BUILDING SHALL HAVE APPROVED ADDRESS NUMBERS (CRC R319.1) IN A POSITION THAT IS PLAINLY VISIBLE FROM THE STREET FRONTING THE PROPERTY. NUMBERS SHALL <br />CONTRAST WITH THEIR BACKGROUND. ADDRESS NUMBERS SHALL BE A MINIMUM 4 INCHES HIGH AND 1/2 INCH STROKE WIDTH <br />-IF ILLUMINATED; COMPLY WITH CALIFORNIA ENERGY CODE SECTION 140.8; OR <br />-SIGN SHALL CONSUME NO MORE THAN 5 WATTS OF POWER AS DETERMINED ACCORDING TO SECTION 130.0(C). <br />9. CONCRETE SLAB AND UNDER-FLOOR INPECTIONSIN SHALL BE MADE ATERAFIN-SLAB O UNDER-FLOOR REINFORCING STEEL AND BUILDINGSERVICE EQUIPMENT, CONDUCTS, PIPING <br />OR ORTHE ANCILLARY BUILDING TRADE PRODUCTS OR EQUIPMENT ARE INSTALLED, BUT BEFORE ANY CONCRETE IS PLACED OR FLOOR SHEATHING IS INSTALLED, INCLUDING THE <br />SUBFLOOR. (R109.1.1.1) <br />10. ROUGH INSPECTION OF PLUMBING, MECHANICAL GAS AND ELECTRICAL SYSTEMS SHALL BE MADE PRIOR TO COVERING OR CONCEALMENT, BEFORE FIXTURES OR APPLIANCES ARE <br />SET OR INSTALLED , AND PRIOR TO FRAMING INSPECTION. (R109.1.2) <br />11. WATER PIPING MATERIALS WITHIN A BUILDING SHALL BE IN ACCORDANCE WITH SEC. 604.1 OF THE CALIFORNIA PLUMBING CODE. PEX, CPVC AND OTHER PLASTIC WATER PIPING <br />SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF SEC.604 OF THE CPC, INSTALLATION STANDARDS OF APPENDIX I OF THE CPC AND MANUFACTURERS <br />RECOMMENDED INSTALLTION STANDARDS. CPVC WATER PIPING REQUIRES A CERTIFICATION OF COMPLIANCE AS SPECIFIED IN SEC 604.1.1 OF THE CPC PRIOR TO PERMIT <br />ISSUANCE. <br />1. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED <br />ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL-BOXES, <br />TRANSFORMERS, VAULTS, PUMPS,VALVES, METERS, ETC) OR TO THE LOCATION OF THE <br />HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES- <br />WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY <br />CAUSE CONSTRUCTION DELAYS AND/ OR ADDITIONAL EXPENSES. <br />2. AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE ON <br />THE DOWN STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE <br />EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING. <br />3. PROVIDE LOW CONSUMPTION WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING <br />SHOWER HEADS AND TOILETS MUST BE ADAPTED FOR LOW WATER CONSUMPTION. <br />4. PROVIDE 72" HIGH NON-ABSORBENT WALL ADJACENT TO SHOWER AND APPROVED <br />SHATTER-RESISTANT MATERIALS FOR SHOWER ENCLOSURE. <br />5. ALL CONSTRUCTION WASTE AND DEBRIS MUST BE CONTAINERIZED AT ALL TIMES <br />6. FINAL APPROVAL REQUIRED BY THE PUBLIC WORKS DEPARTMENT FOR STREET <br />IMPROVEMENTS, CURB CORES, CURB/GUTTERS, ETC. SEPARATE PUBLIC WORKS PERMIT <br />REQUIRED FOR DRIVEWAYS, APPROACH TO DRIVEWAY, SEWER LATERALS AND ANY WORK <br />IN RIGHT OF WAY. <br />7. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL <br />CODES AND AMENDMENTS. <br />8. A SURVEY SHALL BE PROVIDED BY A LICENSED SURVEYOR ON STRUCTURES WHICH DEFINE <br />PROPERTY LINES, SET BACKS, DESIGNATED PARKLAND OR STREET RIGHT-OF-WAY. <br />9. DUST CONTROL MEASURES SHALL BE MAINTAINED THROUGHOUT THE DURATION OF THE <br />PROJECT. <br />10. WATER HEATER MUST BE STRAPPED TO WALL. SEE DETAIL ON SHEET 00-G-300. <br />11. PROVIDE ULTRA FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING SHOWER <br />HEADS AND TOILETS MUST BE ADAPTED FOR WATER CONSUMPTION. <br />12. LAG BOLTS: PROVIDE LEAD HOLE 40%-70% OF THREADED SHANK DIA. AND FULL DIA. FOR <br />SMOOTH SHANK PORTION. 91 NDS <br />13. BLOCKING. ROOF RAFTERS AND CEILING JOINTS SHALL BE SUPPORTED LATERALLY TO <br />PREVENT ROTATION & LATERAL DISPLACEMENT IN ACCORDANCE w/ THE PROVISIONS OF <br />CH.8 & CH.6 <br />14. CONTRACTOR AND/OR OWNER SHALL VERIFY CONSTRUCTION SITE TO CONFIRM THAT <br />THERE IS NO TRACEOF DEMOLISHED SWIMMING POOL WITHIN 5 FT FROM PROPOSED <br />PERIMETER OF THE CONSTRUCTION SITE. OTHERWISE, THEY NEED TO SUBMIT SOIL <br />COMPACTION REPORT FROM LICENSED SOIL ENGINEER TO BUILDING INSPECTOR PRIOR TO <br />FOUNDATION INSPECTION. <br />15. SHEARWALLS, LATHING & PLASTER IN MATERIALS SHALL CONFORM TO THE STANDARD <br />LISTED IN CH.6 & CH.7 CRC <br />16. ALL BOLT HOLES SHALL BE DRILLED 1/32" TO 1/16" OVERSIZED. "ENGINEER" MUST <br />INCLUDE IN STRUCTURAL OBSERVATION NOTES. <br />17. PROVIDE RAIN GUTTERS AND CONVEY RAIN WATER TO THE STREET. <br />18. CONCRETE 2500 PSI <br />19. PARALLEL BEAM E.2.0 PSL <br />20. UFER GROUND IS REQUIRED AT NEW ELECTRICAL SERVICE. <br />21. UNDERGROUND UTILITIES REQUIRED ON SITE PLAN AND SHOW FOR ELECTRICAL, CABLE <br />TV. AND TELEPHONE <br />22. ARC FAULT CIRCUIT INTERRUPTION PROTECTION IS REQUIRED FOR ALL BRANCH <br />CIRCUITS PER 2022 CRC210.12 SHALL BE AFCI PROTECTED <br />23. BATHROOMS, KITCHEN, GARAGE & OUTSIDE OUTLETS WILL BE GFCI PROTECTED <br />RECEPTACLE OUTLETS. <br />24. WATER SAVING WATER CLOSET w/1.28 GALLONS PER FLUSH. <br />25. PROVIDE MECHANICAL VENTILATION FOR BATHROOMS AND LAUNDRY ROOMS WITHOUT <br />OPENABLE WINDOW. <br />26. GLAZING WHICH IS LESS THAN 60 INCHES FROM A FLOOR AND WITHIN A 24" ARC OF A <br />DOORWAY'S VERTICAL EDGE MUST COMPLY WITH CH.3 CRC <br />27. LANDINGS AT DOOR. LANDINGS SHALL HAVE A WIDTH NOT LESS THAN THE WIDTH OF <br />THE STAIRWAY OR THE DOOR, WHICHEVER IS GREATER. <br />28. EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH A <br />NATURAL LIGHT IN ACCORDANCE WITH SECTION R303.1 OR SHALL BE PROVIDE AN <br />AVERAGE ILLUMINATION OF 6 FEET-CANDLES OVER THE AREA OF THE ROOM AT A <br />HEIGHT OF 30" ABOVE THE FLOOR LEVEL. <br />29. THE CONTRACTOR SHALL EXAMINE AND BECOME FAMILIAR WITH ALL CONTRACT <br />DOCUMENTS, SURVEY THE PROPERTY AND BECOME FAMILIAR WITH THE EXISTING <br />CONDITIONS AND SCOPE OF WORK. ALL COST SUBMITTED SHALL BE BASED ON A <br />THROUGH KNOWLEDGE OF ALL WORK AND MATERIALS REQUIRED. ANY DISCREPANCY <br />AND/OR UNCERTAINTY AS TO WHAT MATERIALS OR PRODUCT IS TO BE USED SHOULD <br />BE VERIFIED WITH THE OWNER OR ENGINEER OF RECORD. <br />30. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALE. <br />31. IN THE EVENT A DISCREPANCY IS FOUND IN THE CONTRACT DOCUMENTS, THE OWNER <br />AND THE DESIGNER/ENGINEERS SHALL BE NOTIFIED, IN WRITING, IMMEDIATELY. <br />32. THE CALIFORNIA SWIMMING POOL SAFETY ACT (HEALTH & SAFETY CODE SECTION <br />115920) MANDATES THAT ALL DOORS PROVIDING DIRECT ACCESS FROM THE <br />RESIDENCE TO A NEW SWIMMING POOL AND/OR SPA IS PROVIDE WITH AN APPROVED <br />SAFETY COVER OR THE POOL AND/OR SPA IS ISOLATED FROM DIRECT ACCESS TO THE <br />HOME BY AN APPROVED POOL FENCE AND GATE ENCLOSURE. <br />33. BOTH ADU AND PRIMARY DWELLING ROOF MUST MATCH AND BE SUBSTANTIALLY <br />SIMILAR IN DESIGN, PITCH, COLOR, MATERIAL AND TEXTURE. <br />34. FINAL ELECTRICAL PANEL LOCATION WILL BE AS DETERMINED BY SCE AND <br />CITYINSPECTOR <br />ID BUS STOP: 6639 <br />PROJECT LOCATIONS <br />FIRE HYDRANT LOCATIONS <br />LEGAL JURISDICTION : CITY OF SANTA ANA, CA 92703. <br />THE CURRENT PREVAILING BUILDING AND CONSTRUCTION CODES ARE AS FOLLOWS: <br />2022 CALIFORNIA BUILDING CODE <br />2022 CALIFORNIA RESIDENTIAL CODE <br />2022 CALIFORNIA FIRE CODE <br />2022 CALIFORNIA MECHANICAL CODE <br />2022 CALIFORNIA ELECTRICAL CODE <br />2022 CALIFORNIA PLUMBING CODE <br />2022 CALIFORNIA BUILDING ENERGY EFFICIENCY STANDARDS <br />2022 CALIFORNIA GREEN BUILDING STANDARDS CODE <br />2022 SANTA ANA CITY ZONING AND SUBDIVISION ORDINANCE <br />REGULATION OF THE STATE AND LOCAL FIRE MARSHALS & CITY ORDINANCE. CITY OF <br />SANTA ANA MUNICIPAL CODE. <br />THIS PROPOSED PROJECT CONSISTS OF: <br />-BUILD A NEW DETACHED ADU 749 SF AND NEW PORCH FOR ADU 51 SF, WITH: <br /> 2 BEDROOM, 2 BATHROOM, LIVING+ KITCHEN , LAUNDRY. <br />OWNER: <br />NAME: QK HA FAMILY LIMITED PARTNERSIP AND <br />HUONG HAILEY HA <br />ADDRESS: 421 S CENTER ST, SANTA ANA, CA 92703 <br />PHONE: <br />EMAIL: <br />DESIGNER: <br />NAME: TRINH HA <br />16168 BEACH BLVD, STE#201C, <br />HUNTINGTON BEACH, CA 92647 <br />PHONE: 714-928-8006 <br />EMAIL: <br />ENGINEER OF RECORD: <br />NAME: TUNG VO <br />16168 BEACH BLVD, STE#201C, <br />HUNTINGTON BEACH, CA 92647 <br />PHONE: 714-928-8006 <br />EMAIL: TUNGCIVIL2018@GMAIL.COM <br />AD <br />U <br />. <br /> <br />R <br />E <br />A <br />R <br /> <br />S <br />E <br />T <br />B <br />A <br />C <br />K <br /> <br />R <br />E <br />Q <br />. <br /> <br />FR <br />O <br />N <br />T <br /> <br />S <br />E <br />T <br />B <br />A <br />C <br />K <br /> <br />R <br />E <br />Q <br />. <br /> <br />MH. SIDE SETBACK REQ. <br />(E) <br />PARKING <br />SPACE <br />(E) <br />PARKING <br />SPACE FOR <br />CE <br />N <br />T <br />E <br />R <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />10 <br />' <br />- <br />0 <br />" <br />20'-0" <br />(E) 2 CAR-GARAGE <br />457 SF <br />421 S CENTER ST, <br />SANTA ANA, CA 92703 <br />(E) MAINHOUSE -1 STORY <br />(LIVING AREA = 1,347 SF) <br />(E) ELECTRIC POLE <br />4 <br />7 <br />8 <br />(E <br />) <br /> <br />D <br />R <br />I <br />V <br />E <br />W <br />A <br />Y <br /> <br />A <br />P <br />P <br />R <br />O <br />A <br />C <br />H <br />10 <br />F <br />T <br /> <br />E <br />A <br />S <br />E <br />M <br />E <br />N <br />T <br /> <br />F <br />O <br />R <br /> <br />P <br />U <br />B <br />L <br />I <br />C <br /> <br />U <br />T <br />I <br />L <br />I <br />T <br />I <br />E <br />S <br /> <br />TO CENTERLINE <br />30'-0" <br />(E) <br />3'-0" <br />(E) <br />14'-0" <br />(E) <br />3'-0" <br />511 <br />5'-0" <br />5'-0" <br />MH. SIDE SETBACK REQ. <br />(E) <br />18'-0" <br />(E) <br />8'-0" <br />(E) <br />4'-0" <br />28 <br />EASEMENT <br />10'-0" <br />20'-0" <br />(E) FRONT SETBACK <br />21'-10" <br />(E) <br />42'-10" <br />(E) MH. REAR SETBACK <br />35'-5" <br />(E) <br />26'-10" <br />(E) <br />37'-10" <br />(E) SIDE SETBACK <br />5'-10" <br />(E) <br />47'-4" <br />(E) SIDE SETBACK <br />7'-10" <br />(E) <br />3'-1" <br />(E) <br />1'-0" <br />(E) <br />1'-0" <br />(E) <br />1'-0" <br />2'-0" <br />2'-0" <br />1'-0" <br />(E) <br />3'-9" <br />(E) <br />1'-0" <br />(E) <br />1'-0" <br />(E) <br />1'-0" <br />(E) <br />5'-0" <br />(E) <br />20'-10" <br />(E) OVERHANG <br />6'-0" <br />(E) <br />4'-10" <br />(E) <br />1'-0" <br />(E) <br />19'-9" <br />(E) <br />7'-8" <br />(E) <br />23'-0" <br />(E) <br />23'-4" <br />(E) <br />19'-6" <br />22 <br />20 <br />20 <br />20 <br />20 <br />20 <br />20 <br />24 <br />24 <br />24 <br />24 <br />24 <br />24 <br />17 <br />17 <br />1717.2 <br />17.3 <br />17.3 <br />17.3 <br />30.1 <br />PL 100.08' <br />PL <br /> <br />6 <br />1 <br />. <br />0 <br />0 <br />' <br />PL <br /> <br />6 <br />1 <br />. <br />0 <br />0 <br />' <br />PL 100.06'' <br />1.21.41.31.7 <br />1.5 <br />2.22.1 <br />(E) GARAGE SETBACK <br />4'-9"(E) <br />6'-10" <br />(E) <br />1'-0" <br />ADU. SIDE SETBACK REQ. <br />ADU. SIDE SETBACK REQ. 4'-0" <br />4'-0" <br />24 <br />28.1 <br />16.1 (N) <br />PORCH <br />51 SF <br />5'-5 1/2" <br />9'-4"9'-7" <br />4'-0" <br />1'-0" <br />6"10'-0" <br />12'-8 1/2" <br />1'-0" <br />F.S.D <br />3'-0" <br />F.S.D <br />3'-0" <br />33 <br />31 <br />24 <br />24 <br />24 <br />14 <br />14 <br />14 <br />99 <br />8.1 <br />16 <br />(E) PORCH <br />201 SF <br />DISTANCE TO BUILDING <br />6'-0"18'-11" <br />ADU. REAR SETBACK <br />10'-6" <br />423 S CENTER ST, <br />SANTA ANA, CA 92703 <br />(N) DETACHED ADU -1 STORY <br />(LIVING AREA = 749 SF) <br />ADU. SIDE SETBACK <br />13'-8 1/2" <br />42'-3 1/2" <br />ADU. SIDE SETBACK <br />5'-0" <br />1 <br />01-A-301 <br />1 <br />01-A-301 <br />2 <br />01-A-301 <br />4 <br />01-A-301 <br />3 <br />01-A-301 <br />13 <br />11.1 <br />11.1 <br />10.1 <br />(E) <br />20'-0" <br />20.1 <br />(N) LANDSCAPE AREA= 153 SF <br />(E) LANDSCAPE AREA= 720 SF <br />HARDSCAPE AREA = 458 SF <br />36'-10" <br />99 <br />12'-4 1/2" <br />3'-11 1/2" <br />6'-0" <br />3'-0" <br />(N <br />) <br /> <br />L <br />A <br />N <br />D <br />I <br />N <br />G <br /> <br /> <br />18 <br /> <br />S <br />F <br />7'-0" <br />3'-0"(N) LANDING <br />21 SF <br />8.1 <br />2025.03 <br />10.10.2025 <br />©2025Sheet No. <br />Rev. <br />Project No. <br />Date Print: <br />Design by <br />TRINH HA. <br />Date. <br />Pr <br />o <br />j <br />e <br />c <br />t <br />: <br />Description. <br />1.07.23.2025Correction 1st. <br />2.09.12.2025Correction 2nd. <br />3.10.20.2025Correction 3rd. <br />01-A-000 <br />CE <br />N <br />T <br />E <br />R <br /> <br />S <br />T <br /> <br />- <br />RE <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />Ad <br />d <br />r <br />e <br />s <br />s <br /> <br />M <br />a <br />i <br />n <br /> <br />H <br />o <br />u <br />s <br />e <br />: <br /> <br />4 <br />2 <br />1 <br /> <br />S <br /> <br />C <br />e <br />n <br />t <br />e <br />r <br /> <br />S <br />t <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />92 <br />7 <br />0 <br />3 <br />Ad <br />d <br />r <br />e <br />s <br />s <br /> <br />D <br />e <br />t <br />a <br />c <br />h <br />e <br />d <br /> <br />A <br />D <br />U <br />: <br /> <br />4 <br />2 <br />3 <br /> <br />S <br /> <br />C <br />e <br />n <br />t <br />e <br />r <br /> <br />S <br />t <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br />9 <br />2 <br />7 <br />0 <br />3 <br />PROJECT DATA / <br />SITE PLAN <br />CONSTRUCTION NOTES <br />GENERAL NOTES <br />VICINITY MAPPROJECT DATA SHEET INDEX <br />SYMBOL LEGEND <br />SCOPE OF WORK <br />APPLICABLE CODES <br />SITE PLAN KEYNOTES <br />DIG ALERT (811) IS TO BE CONTACTED AND THAT COMPLIANCE WITH <br />EXCAVATION SAFETY IN ACCORDANCE WITH GOVERNMENT CODE 4216 WILL <br />BE FOLLOWED PRIOR TO ANY EXCAVATION TAKING PLACE. <br />DIG ALERT 811 <br />DIRECTORY <br />PARCEL MAP <br />00-G-000 COVER SHEET <br />00-G-200 CAL GREEN CODE <br />00-G-201 CAL GREEN CODE <br />00-G-300 GENERAL DETAILS <br />01-A-000 PROJECT DATA / SITE PLAN <br />01-A-001 EXISTING SITE PLAN <br />01-A-100 EXISTING_MAINHOUSE FLOOR PLANS <br />01-A-101 EXISTING_MAINHOUSE ELEVATIONS <br />01-A-200 PROPOSED_ ADU FLOOR & ROOF PLAN <br />01-A-201 PROPOSED_ ELEVATIONS & SECTIONS <br />01-A-202 DOOR & WINDOW SCHEDULE <br />01-A-300 ARCHITECTURAL DETAILS <br />01-A-301 FIRE PROTECTION DETAILS <br />04-D-001 DRAINAGE PLAN <br />05-E-001 PROPOSED_ADU CEILING ELECTRICAL PLAN <br />02-S0.0 GENERAL STRUCTURAL NOTES <br />02-S0.1 TYPICAL DETAILS <br />02-S1.0 FOUNDATION PLAN AND FRAMING PLAN <br />02-SD1 STRUCTURAL DETAILS <br />02-SD2 STRUCTURAL DETAILS <br />03-T-000 TITLE 24 MANDATORY MEASURES SUMMARY <br />03-T-001 TITLE 24 _DETACHED ADU <br />1.2 (N) ELECTRICAL PANEL FOR ADU 200 AMP, WITH A 225A BUS BAR <br />1.3 "(N) 60 AMP SUBPANEL FOR ADU ESS SYSTEM" <br />1.4 (N) ELECTRICAL METER FOR ADU 200 AMP <br />1.5 UPGRADE ELECTRICAL SUB PANEL FOR MAINHOUSE 200 AMP, WITH A 225A BUS BAR <br />1.7 (N) ELECTRICAL METER FOR MAINHOUSE 200 AMP, RELOCATION <br />2.1 (N) ELECTRICAL WIRE UNDERGROUND CONNECT FROM ELECTRIC METER/PANEL <br />2.2 (N) DROP ELECTRIC WIRE UNDERGROUND CONNECT FROM ELECTRIC POLE <br />4 (E) GAS METER <br />5 (E) GAS SUPPLY LINE, 3/4" MIN. STAINLESS STEEL PIPE <br />7 (E) WATER METER <br />8 (E) WATER SUPPLY LINE, 1" MIN. COPPER PIPE <br />8.1 (N) WATER SUPPLY LINE, 1" MIN. COPPER PIPE OR 1" MIN. POLYVINYL CHLORIDE PIPE CONNECTED FROM THE <br />EXISTING SYSTEM OF THE MAIN HOUSE <br />10.1 (N) CLEAN-OUT <br />11 (E) SEWER LINE CONECTED TO EXISTING SYSTEM OF THE CITY <br />11.1 "(N) SEWER LINE. (4'' MIN. DIA. SEWER LINE, FROM (N) DWELLING UNIT WITH MINIMUM 2% SLOPE FRO <br />DRAINAGE)" <br />13 (E) DRIVEWAY PARKING <br />14 (E) WALKWAY / (E) YARD CONCRETE <br />16 (E) LANDING <br />16.1 (N) LANDING. 1 1/2" BELOW THRESHOLD.MINIMUM 36" IN DEPTH. MIN. 2% SLOPE AWAY FROM BUILDING. <br />17 (E) PERIMETER FENCE, 6FT HEIGHT- BLOCK WALL <br />17.2 (E) PERIMETER FENCE- STELL, 6FT HEIGHT <br />17.3 (E) PERIMETER FENCE- BLOCK WALL & STELL ABOVE, 5FT HEIGHT (V.I.F) <br />20 (E) LANDSCAPE <br />20.1 (N) LANDSCAPE <br />22 (E) TREE <br />24 ROOF/ FLOOR LINE ABOVE <br />28 (E) POST <br />28.1 (N) POST, PER STRUCT. <br />30.1 (E) AC UNIT <br />31 (N) DUCTLESS MULTI-SPLIT SYSTEM AC. PER T-24 <br />33 (N) HEAT PUMP WATER HEATERS PER T-24, MODEL: PROPH50 T2 RH37515 (50 GAL, JA13) , EQUIPMENT <br />CABINET TO BE PAINTED TO MATCH THE ADU EXTERIOR MATERIALS <br />99 1HR FIRE-RATED WALL PROVIDE UNPROTECTED OPENING MAX 25% OF WALL AREA, SEE CALCUALTION ON <br />ELEVATION VIEW. <br />1/8" = 1'-0"1PROPOSED SITE PLAN <br />3 <br />3 <br />3