My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10180344_W 4TH - Plan (2)
PBA
>
Building
>
Plans
>
F
>
Fourth St
>
209 W Fourth St
>
10180344_W 4TH - Plan (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/19/2021 12:42:35 AM
Creation date
10/25/2020 9:48:01 PM
Metadata
Fields
Template:
Plan
Permit Number
10180344
Full Address
209 W Fourth St
Fully Linked
True
Document Relationships
10180344 - Permit
(Permit - Plan)
Path:
\Building\Permits\F\Fourth St\209 W Fourth St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ESR-1772 I Most Widely Accepted and Trusted Page 5 of 6 <br />TABLE 3-ALLOWABLE LOAD CAPACITIES FOR THREADED RODS AND REINFORCING BARS FOR SET ADHESIVE ANCHOR <br />SYSTEMS INSTALLED IN UNREINFORCED BRICK MASONRY1.2 <br />CONFIGURATION A - SHEAR ANCHOR OR REBAR DOWEL <br />Anchor Rod Minimum Minimum Allowable Allowable <br />Diameter or Rebar Size Embedment Wall Thickness Tension Load Shear Load3 <br />(inches)(inches)(lbs)(lbs) <br />3/4 8 13 - 1,000 <br />No. 5 8 13 - 750 <br />No. 6 8 13 - 1,000 <br />CONFIGURATION B - 221/2° COMBINATION ANCHOR <br />Anchor Rod Minimum Minimum Allowable Allowable <br />Diameter Embedment Wall Thickness Tension Load)Shear Load' <br />(inch)(inches)(lbs)(lbs) <br />314 Within 1 inch of <br />opposite wall surface 13 1,200 1,000 <br />CONFIGURATION C - THROUGH-BOLT ANCHOR <br />Anchor Rod Dia. <br />(inch) <br />Minimum Steel Minimum Allowable <br />Sleeve Embedment Wall Thickness Tension Load <br />(inches)(lbs) <br />Allowable <br />3 Shear Load3 <br />(lbs) <br />5/8 8 inches Rom <br />interiorwall surfaoe 13 1,200 750 <br />For SI: 1 inch = 25.4 mm, 1 Ibf = 4.45 N, 1 foot-pound = 1.356 N-m, 1 psi = 6.89 Pa. <br />1Allowable load values are applicable only to anchors where in-place shear tests indicate minimum mortar strength of 50 psi, net. <br />2No increase for lateral loading, such as loading induced by wind or earthquake, is permitted. <br />Anchors must be tested in accordance with Section 4.4 for use with the IEBC. <br />Configuration A <br />(Shear) <br />PLASTIC <br />OR STEEL <br />J l SCREEN TUBE <br />F"0-#=Sium,, *44,K,110*414'*ilr,2 f,,1 <br />Configuration B Configuration C <br />(Tension & Shear)(Tension & Shear) <br />- 6.16.xw <br />STEEL <br />PLASTIC PLATE <br />Z OR STEEL L. <br />SCREEN TUBE <br />, <br />4f *.• DIA. <br />BENT HEX <br />THREADED NUT <br />ROD <br />STEEL <br />SCREEN TUBE <br />/ , STEEL SLEEVE <br />J \ <br />W DIA. <br />ROD <br />FIGURE 1-ANCHOR INSTALLATIONS FOR UNREINFORCED BRICK MASONRY <br />(Refer to Sections 4.1 through 4.3 for details concerning design and installation of anchors in unreinforced brick masonry)
The URL can be used to link to this page
Your browser does not support the video tag.