My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10180524_2528 N. JACARANDA - Plan (2)
PBA
>
Building
>
Plans
>
J
>
Jacaranda St
>
2528 N Jacaranda St
>
10180524_2528 N. JACARANDA - Plan (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/14/2023 8:23:33 AM
Creation date
10/25/2020 9:48:47 PM
Metadata
Fields
Template:
Plan
Permit Number
10180524
Full Address
2528 N Jacaranda St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SOLARMOUNT Technical Datasheets :FUNIRAC <br />A Mtln GROUP COM;'AM·,• <br />SolarMount Technical Datasheet <br />Pub 110818-ltd Vi.0 August 2011 <br />SolarMount Module Connection Hardware 1 <br />Bottom Up Module Clip 1 <br />Mid Clamp · 9 <br />End Clamp 2 <br />SolarMount Beam Connection Hardware 3 <br />L-Foot. 3 <br />SolarMount Beams 4 <br />Solar[Viount Module Connection Hardware <br />SolarMount Bottom Up Module Clip <br />Part No. 302000C <br />4 <br />Bottom 2 Washer ·Bottom Up Clip material: One of the following extruded aluminum <br />'Nut (hidden..g»alloys: 6005-T5, 6105-T5, 6061-T6 <br />· Ultimate tensile: 38ksi, Yield: 35 ksi <br /> Finish: Clear Anodized <br />e Bottom Up Clip weight: -0.031 lbs (149) <br />14*244 .-fit - Allowable and design loads are valid when components are <br />assembled with SolarMount series beams according to authorized <br />UNIRAC documents <br />Assemble with one W-20 ASTM F593 bolt, one W,-20 ASTM F594 <br />serrated flange nut, and one W' flat washer <br />· Use anti-seize and tighten to 10 ft-lbs of torque <br /> · Resistance factors and safety factors are determined according to <br />part 1 section 9 of the 2005 Aluminum Design Manual and third- <br />party test results from an IAS accredited laboratory <br /> Module edge must be fully supported by the beam <br />fri Up Clip / <br />Beam ... <br />'A -1 <br />* NOTE ON WASHER: Install washer on bolt head side of assembly. <br />DO NOT install washer under serrated flange nut <br />31 LY <br />A /7,1 - <br />+X cli <br />1.24 <br />t.(•) <br />Applied Load Average Allowable Safety Design Resistance <br />Direction Ultimate Load Factor,Load Factor, <br />lbs (N)lbs (N)FS lbs (N) .O <br />Tension, Y+1566 (6967)686 (3052)2.28 1038 (4615)0.662 <br />Transverse, X+1128 (5019)329 (1463)3.43 497 (2213)0.441 <br />Sliding, Zi 66 (292)27 (119)2.44 41 (181)0.619 <br />Dimensions specified in inches unless noted
The URL can be used to link to this page
Your browser does not support the video tag.