Laserfiche WebLink
DS <br /> <br />D <br />S <br />DS <br />D <br />S <br />DS <br />DS <br /> <br />D <br />S <br />DS <br />DS <br />D <br />S <br />DS <br />45' <br />2020 <br />20 20 <br />43 <br />A020 <br />South <br />FSD <br />LAUNDRY <br />131 SF <br />40 <br />BL <br />D <br />G <br /> <br />A <br />1 <br />BL <br />D <br />G <br /> <br />A <br />2 <br />10 <br />' <br /> <br />- <br /> <br />4 <br /> <br />3 <br />/ <br />4 <br />" <br />4' - 5 3/8"11' - 11 1/2" <br />BUILDING TYPE: V-A <br />OCC. GROUP: U - UTILITY <br />FIRE SPRINKLER TYPE: NFPA-13 <br />FIRE SEPARATION DESTIANCE = 0'-7 5/8" <br />MAX. ALLOWED UNPROTECTED OPENING = NOT PERMITTED <br />NO OPENINGS AT TRASH ENCLOSURE, SEE , COMPLIES <br />10 <br />' <br /> <br />- <br /> <br />4 <br /> <br />3 <br />/ <br />8 <br />" <br />7 5/8" <br />TRASH <br />A <br />B <br />1 <br />A901 <br />/1 A901 <br />A201Ea <br />s <br />t <br />A201 <br />A201 <br />A201 <br />North <br />W <br />e <br />s <br />t <br />South <br />76' <br />20 <br />20 <br />20 <br />20 20 <br />A020 <br />South <br />FSD <br />10' - 0" <br />10 <br />' <br /> <br />- <br /> <br />4 <br /> <br />3 <br />/ <br />8 <br />" <br />x' <br />y <br />X <br />EGRESS AND OCCUPANCY LEGEND <br />MAXIMUM TRAVEL DISTANCE (1017.2) <br />R-2 = 250' MAX <br />OCCUPANCY TYPE <br />AREA OF SPACE <br /># OF OCCUPANTS <br />OCCUPANT LOAD <br />FACTOR PER CBC <br />1004.1.2 <br />y <br />EXIT DOOR (AND MAX # OF OCCUPANTS SERVED BY DOOR) <br />EXIT DISCHARGE (AND MAX # OF OCCUPANTS SERVED) <br />DOOR FIRE RATING (PROVIDED FOR CONVENIENCE, SEE PLANS <br />FOR DOOR TAGS AND DOOR SCHEDULE FOR ADDITIONAL INFO) <br />X <br />X <br />X <br />z <br />23.4 <br />35.0 <br />2.4 <br />1RST FLOOR <br />TOTAL WALL AREA: 663.0 SF <br />TOTAL OPENING AREA : 2*2.4 + 2*23.4 + 2*35 = 121.6 SF <br />PERCENTAGE: 18.3% <br />2ND FLOOR <br />TOTAL WALL AREA: 605.3 SF <br />TOTAL OPENING AREA : 2*2.4 + 2*23.4 = 51.6 SF <br />PERCENTAGE: 8.5% <br />BUILDING TYPE: VA <br />EXTERIOR BEARING WALL PROTECTION: 1 HR <br />EXTERIOR NON BEARING WALL PROTECTION: 0 HR <br />FIRE SEPARATION DESTIANCE = 10'-0" <br />MAX. ALLOWED UNPROTECTED OPENING = 45% <br />9' <br /> <br />- <br /> <br />1 <br />" <br />9' <br /> <br />- <br /> <br />1 <br />1 <br /> <br />1 <br />/ <br />2 <br />" <br />66' - 7" <br />9' <br /> <br />- <br /> <br />1 <br />" <br />9' <br /> <br />- <br /> <br />1 <br />1 <br /> <br />1 <br />/ <br />2 <br />" <br />23.4 <br />53.3 <br />2ND FLOOR <br />TOTAL WALL AREA: 528.5. SF <br />TOTAL OPENING AREA : 4*23.4+53.3 = 146.9 SF <br />PERCENTAGE: 27.8% <br />1RST FLOOR <br />TOTAL WALL AREA: 668.0 SF <br />TOTAL OPENING AREA : 122.2 SF <br />PERCENTAGE: 18.3% <br />BUILDING TYPE: VA <br />EXTERIOR BEARING WALL PROTECTION: 1 HR <br />EXTERIOR NON BEARING WALL PROTECTION: 0 HR <br />FIRE SEPARATION DESTIANCE = 10'-4 3/4" TO PL <br />DISTANCE IMAGINARY LOT LINE AT TRASH = 10'-1" <br />MAX. ALLOWED UNPROTECTED OPENING = 45% <br />28.6 <br />57' - 11 1/2" <br />TRASH <br />11' - 11 1/2" <br />TR <br />A <br />S <br />H <br />6' <br /> <br />- <br /> <br />0 <br />" <br />1RST FLOOR - TRASH <br />TOTAL WALL AREA: 71.8 SF <br />TOTAL OPENING AREA : 13.2 SF <br />PERCENTAGE: 18.3% <br />al <br />l <br /> <br />i <br />d <br />e <br />a <br />s <br />, <br /> <br />d <br />e <br />s <br />i <br />g <br />n <br />s <br /> <br />a <br />n <br />d <br /> <br />p <br />l <br />a <br />n <br />s <br /> <br />r <br />e <br />p <br />r <br />e <br />s <br />e <br />n <br />t <br />e <br />d <br /> <br />b <br />y <br /> <br />t <br />h <br />i <br />s <br /> <br />d <br />r <br />aw <br />i <br />n <br />g <br /> <br />a <br />r <br />e <br /> <br />t <br />h <br />e <br /> <br />e <br />x <br />c <br />l <br />u <br />s <br />i <br />v <br />e <br /> <br />p <br />r <br />o <br />p <br />e <br />r <br />t <br />y <br /> <br />o <br />f <br /> <br />bs <br />b <br /> <br />d <br />e <br />s <br />i <br />g <br />n <br />, <br /> <br />i <br />n <br />c <br />. <br /> <br />an <br />d <br /> <br />s <br />h <br />a <br />l <br />l <br /> <br />n <br />o <br />t <br /> <br />b <br />e <br /> <br />r <br />e <br />p <br />r <br />o <br />d <br />u <br />c <br />e <br />d <br /> <br />i <br />n <br /> <br />w <br />h <br />o <br />l <br />e <br /> <br />o <br />r <br /> <br />i <br />n <br /> <br />p <br />a <br />r <br />t <br /> <br />w <br />i <br />t <br />ho <br />u <br />t <br /> <br />t <br />h <br />e <br /> <br />e <br />x <br />p <br />r <br />e <br />s <br />s <br /> <br />p <br />r <br />i <br />o <br />r <br /> <br />w <br />r <br />i <br />t <br />t <br />e <br />n <br /> <br />p <br />e <br />r <br />m <br />i <br />s <br />s <br />i <br />o <br />n <br /> <br />o <br />f <br /> <br />s <br />a <br />i <br />d <br /> <br />a <br />rc <br />h <br />i <br />t <br />e <br />c <br />t <br />s <br />, <br /> <br />a <br />n <br />y <br /> <br />u <br />n <br />a <br />u <br />t <br />h <br />o <br />r <br />iz <br />e <br />d <br /> <br />r <br />e <br />u <br />s <br />e <br /> <br />o <br />f <br /> <br />t <br />h <br />e <br />s <br />e <br /> <br />p <br />l <br />a <br />n <br />s <br /> <br />o <br />t <br />h <br />e <br />r <br /> <br />t <br />h <br />a <br />n <br /> <br />f <br />o <br />r <br /> <br />t <br />h <br />e <br /> <br />p <br />r <br />o <br />j <br />e <br />c <br />t <br />a <br />n <br />d <br /> <br />l <br />o <br />c <br />a <br />t <br />i <br />o <br />n <br /> <br />s <br />h <br />o <br />w <br />n <br /> <br />i <br />s <br /> <br />p <br />r <br />o <br />h <br />i <br />b <br />i <br />t <br />e <br />d <br />. <br />JOB NO. <br />SUBMITTAL <br />DATE <br />SHEET TITLE <br />SHEET NO. <br />CLIENT: <br />Plot Date:File: <br />REVISION <br />DATE <br />21 <br />3 <br />0 <br /> <br />E <br /> <br />4 <br />T <br />H <br /> <br />S <br />T <br /> <br /># <br />2 <br />0 <br />0 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />1ST PLAN CHECK SUBMITTAL 08/20/2024 <br />970 W. 190TH ST., STE 250, TORRANCE CA 90502 <br />O: 310.217.8885 <br />BSBDESIGN.COM <br />D E S I G N <br />BSB <br />4TH P.C. SUBMITTAL <br />07/08/2025 <br />2ND PLAN CHECK SUBMITTAL 01/29/2025 <br />3RD PLAN CHECK SUBMITTAL 04/17/2025 <br />4TH PLAN CHECK SUBMITTAL 07/08/2025 <br />11/4/2025 8:52:21 PM <br />MR230056 <br />A020 <br />PROJECT INFORMATION <br />OL <br />I <br />V <br />E <br /> <br />C <br />R <br />E <br />S <br />T <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />T <br />I <br />A <br />L <br />21 <br />5 <br />0 <br /> <br />E <br />. <br /> <br />F <br />O <br />U <br />R <br />T <br />H <br /> <br />S <br />T <br />. <br /> <br />& <br /> <br />2 <br />1 <br />6 <br />0 <br /> <br />E <br />. <br /> <br />F <br />O <br />U <br />R <br />T <br />H <br /> <br />S <br />T <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />OL <br />I <br />V <br />E <br /> <br />C <br />R <br />E <br />S <br />T <br />PROJECT LOCATION <br />APN: 400-091-23 <br />PROJECT ADDRESS: 2130 E. 4TH STREET <br /> SANTA ANA, CA 92705 <br />PROJECT DESCRIPTION <br />THE PROJECT CONSISTS OF 15 UNITS OF SUPPORTIVE MULTI-FAMILY HOUSING CONSISTING OF <br />ONE EIGHT-UNIT AND ONE SEVEN UNIT TWO STORY BUILDINGS, A TRASH ENCLOSURE & LIGHT <br />STANDARDS TO BE CONSTRUCTED ON THE CLIENT'S SITE IN THE CITY OF SANTA ANA, CA. <br />BUILDING "A1 & A2" : 2-STORY (15 - UNITS) <br />1. BUILDING A1: 2-STORY - 7 UNITS & A COMMUNITY ROOM <br />2. BUILDING A2: 2-STORY - 8 UNITS <br />(1) LIGHT STANDARD, (20) COMMERICAL PARKING SPACES <br />PROJECT SUMMARY AND ZONING INFORMATION <br />ZONE: OVERLAY ZONE ("MEMU"), DISTRICT CENTER - MEDIUM HIGH <br />LOT SIZE: 115,029 S.F (2.64 ACRES) <br />AREA OF IMPROVEMENT: 13,801 S.F (0.32 ACRES) <br />FLOOR AREA: RESIDENTIAL: 3,988 S.F. x 2 = 7,976 SF / BLDG. <br />DENSITY: 15 UNITS / 2.64 ACRES = 5.68 UNITS PER ACRE (GROSS) <br />15 UNITS / 0.32 ACRES = 46.87 UNITS PER ACRE (NET) <br />FLOOR AREA RATIO ALLOWED TOTAL FLOOR AREA RATIO: N/A <br />(F.A.R.): PROVIDED TOTAL FLOOR AREA / LOT AREA: <br />15,892 SF + (+/- 27,951 SF ) = 43,843 SF / 115,029 SF = 0.38 FAR <br />MAXIMUM BUILDING HEIGHT: MEMU OVERLAY: 6 STORIES [SAMC-MEMU OVERLAY] <br /> +/- 26' - 0" PROPOSED <br />LOT COVERAGE: N/A 38% OR 43,903 SF PROVIDED <br />TOTAL LANDSCAPE AREA 3,080 SF PROVIDED <br />BUILDING SETBACKS: REQUIRED: PROVIDED <br />SAMC (MEMU ZONE) MIN. MAX. MIN. MAX. <br />BLDG. TO STREET & PARKING <br />ADJACENT TO PUBLIC ST ROW - 10' N/A N/A <br />ADJACENT TO ALLEY OR INTERN AISLE 3' - 4'-6" N/A <br />ADJACENT TO PARKING 7' - 10' N/A <br />CLEAR ZONE 25' - N/A N/A <br />BUILDING TO PROPERTY LINE <br />ADJACENT TO RES. USES <br /> 1ST & 2ND FLOOR 15' - N/A N/A <br /> 3RD FLR & ABOVE 20'/30' - N/A N/A <br />ADJ. TO ALL OTHER USES <br /> ALL FLOORS 5' - 10' 10' <br />BUILDING TO BUILDING <br /> UP TO 3RD FLOOR 6' - 10' 10' <br /> 4TH FLOOR AND ABOVE 15' - N/A N/A <br />OPEN SPACE: (SAMC - MEMU OVERLAY) # OF UNITS S.F. REQ. <br />PRIVATE / COMMON OPEN SPACE - 90 S.F. / DU 15 1,350 S.F. <br />PUBLICLY ACCESSIBLE COMMON OPEN SPACE - 10% 0F T0TAL LOT AREA 11,503 S.F. <br />TOTAL OPEN SPACE REQUIRED: 12,853 SF <br />PRIVATE / COMMON OPEN SPACE PROVIDED 761 + 1,430SF / 146 SF PER UNIT <br />TOTAL OPEN SPACE PROVIDED: 0 SF / 0% OF TOTAL LOT AREA <br />(PUBLICLY ACCESSIBLE) (CONCESSION REQUESTED) <br />P BK 42 PG 43 PAR 1 PARCEL MAP 42-43 PAR 1 AND POR PAR 1 OF PARCEL <br />LEGAL DESCRIPTION: <br />R2 / A3: BUILDING HEIGHT ALLOWED (CBC TABLE 504.3): 70 FEET, 4 STORIES <br />- WITHOUT AREA INCREASE <br />PROPOSED: 2 STORIES, +/- 26'-0" TOP OF RIDGE, R-2, TYPE VA <br />ALLOWED: 70 FEET* - COMPLIES <br />MAX ALLOWABLE HEIGHT <br />OPEN SPACE / COMMON / PRIVATE SUMMARY <br />(E) COMMERCIAL PARKING 152 STALLS (2 VAN ACCESSIBLE, 3 STANDARD ACCESSIBLE) <br />PARKING COMMERCIAL PARKING 129 (2 VAN ACCESSIBLE, 3 STANDARD ACCESSIBLE) <br />RESIDENTIAL PARKING REQ'D. 0 <br />RESIDENTIAL PARKING PROVIDED 2* (1 VAN ACCESSIBLE, 1 STANDARD ACCESSIBLE) <br />TOTAL PARKING STALLS PROVIDED: 131 (3 VAN ACCESSIBLE, 4 STANDARD ACCESSIBLE) <br />* NOTE: RESIDENTIAL PARKING STALLS PROVIDED PER THE CITY OF SANTA ANA ARE VOLUNTARY AND NOT <br /> REQUIRED <br />PARKING SUMMARY <br />TYPE OF CONSTRUCTION <br />OCCUPANCY <br />BLDG "A1 & A2" AND TRASH ENCLOSURE: VA - FULLY SPRINKLED (NFPA 13) <br />BUILDINGS "A1 & A2" : FULLY SPRINKLERED (NFPA 13) <br />AUTOMATIC FIRE SPRINKLERS SHALL BE NFPA 13 AUTOMATIC FIRE SPRINKLER SYSTEM IN COMPLIANCE W/ <br />SECTION (903.3.1.1). QUICK RESPONSE SPRINKLERS SHALL BE INSTALLED IN ACCORDANCE W/ SECTION <br />903.3.1 IN ALL DWELLING UNITS. <br />R-2: RESIDENTIAL UNITS <br />BUILDING CODE ANALYSIS <br />GOVERNING CODES <br />2022 CALIFORNIA BUILDING CODE (CBC) <br />2022CALIFORNIA ELECTRICAL CODE (CEC) <br />2022 CALIFORNIA MECHANICAL CODE (CMC) <br />2022 CALIFORNIA PLUMBING CODE (CPC) <br />2022 CALIFORNIA FIRE CODE (CFC) <br />2022 CALIFORNIA GREEN BUILDING CODE (CGBC) <br />2022 CALIFORNIA ENERGY CODE (CEC) <br />PROPOSED: <br />R-2 , TYPE VA - 2 STORIES, +/- 26'-0" TOP OF RIDGE <br />ALLOWED: 3 STORIES* - COMPLIES <br />*FOR GROUP NON SEPARATED OCCUPANCIES WITH A3 OCCUPANCY BUILDINGS OF TYPE VA <br />CONSTRUCTION EQUIPPED THROUGHOUT WITH AN APPROVED AUTOMATIC SPRINKLER SYSTEM IN <br />ACCORDANCE WITH SECTION 903.3.1.1. <br />MAX ALLOWABLE STORIES <br />PROPOSED: <br />R-2, B, U - TYPE VA <br />ALLOWABLE FOR MIXED OCCUPANCY, 2 STORY BUILDING (506.2.2) = 15,892 -COMPLIES <br />*BUILDINGS TWO OR MORE STORIES ABOVE GRADE PLANE EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM <br />INSTALLED IN ACCORDANCE WITH SECTION 903.3.1.1. <br />MAX ALLOWABLE AREA <br />CBC TABLE 504.3 <br />CBC TABLE 504.4 <br />CBC TABLE 506.2 <br />FUNDING SOURCE & ACCESSIBILITY REQUIREMENTS <br />THIS PROJECT IS 100% PRIVATELY FUNDED / PRIVATELY OWNED <br />SCALE:1/8" = 1'-0" <br />BLDG 1 (& BLDG 2) LEVEL 1 & TRASH 1 <br />SCALE:1/8" = 1'-0" <br />BLDG 2 (& BLDG 1) 2ND LEVEL 2 <br />FIRE RESISTANCE (TYPE VA)CBC TABLE 601 <br />UTILITY - ACCESSORY OCCUPANCY <br />214 SF < 10% OF FLOOIR AREA <br />506.2.2 Mixed-Occupancy Two Story Building: <br />The allowable area of each story of a mixed-occupancy building shall be determined in accordance with the <br />applicable provisions of, Section 508.3.2 <br />Aa = [At + (NS × If)] <br />where: <br />Aa = Allowable area (square feet). <br />At = Tabular allowable area factor (NS, S13R or SM value, as applicable) in accordance with Table 506.2. <br />NS = Tabular allowable area factor in accordance with Table 506.2 for a nonsprinklered building (regardless of <br />whether the building is sprinklered). <br />If, = Area factor increase due to frontage (percent) as calculated in accordance with Section 506.3.. <br />BEARINGS WALLS <br />EXTERIOR: 1-HOUR <br />INTERIOR : 1-HOUR <br />NON-BEARING WALLS & PARTITIONS (EXTERIOR) - TABLE 705.5 <br />5 ≤ X < 10 1-HOUR <br />X ≥ 30 0-HOUR <br />NON-BEARING WALLS & PARTITIONS (INTERIOR) 0-HOUR <br />FLOOR CONSTRUCTION 1-HOUR <br />ROOF CONSTRUCTION 1-HOUR <br /> <br />EGRESS WIDTH PER (1005.3.1) <br />MAX. OCC SERVED BY STAIR (this level) 40 <br />EGRESS WIDTH FACTOR (1005.3.1) = 0.3 <br />MIN. REQ. STAIR CLEAR WIDTH (40 x 0.3) = 12" <br />MIN. PROVIDED STAIR CLEAR WIDTH = 44" <br />MIN. PROVIDED CLEAR DOOR WIDTH: = 64" <br />EXIT TRAVEL DISTANCE ( TABLE 1017.2) <br />OCCUPANCY R, WITH SPRINKLER SYSTEM <br />MAXIMUM ALLOWED TRAVEL DISTANCE = 250' <br />MAX. PROVIDED TRAVEL DISTANCE = 121' <br />CO <br />M <br />P <br />L <br />I <br />E <br />S <br />R2 3,988 SF <br />200 20 <br />RESIDENTIAL <br />STAIR EGRESS WIDTH PER (1005.3.1) <br />MAX. OCC SERVED BY STAIR (this level) 20 <br />EGRESS WIDTH FACTOR (1005.3.1) = 0.3 <br />MIN. REQ. STAIR CLEAR WIDTH (20 x 0.3) = 6" <br />MIN. PROVIDED STAIR CLEAR WIDTH = 44" <br />MINIMUM CORRIDOR WIDTH ( TABLE 1020.3) <br />OCCUPANT LOAD LESS THAN 50 <br />MINIMUM REQUIRED WIDTH = 36" <br />MINIMUM PROPOSED WIDTH = 36" <br />CO <br />M <br />P <br />L <br />I <br />E <br />S <br />CO <br />M <br />P <br />L <br />I <br />E <br />S <br />MINIMUM CORRIDOR WIDTH ( TABLE 1020.3) <br />OCCUPANT LOAD LESS THAN 50 <br />MINIMUM REQUIRED WIDTH = 36" <br />MINIMUM PROPOSED WIDTH = 36" <br />CO <br />M <br />P <br />L <br />I <br />E <br />S <br />ALLOWABLE BLDG AREA -RESIDENTIAL BLDG -SINGLE <br />LEVEL <br />LEVEL 1 <br />AREA <br />DESCRIPTION BLDG # <br />OCCUPANCY / <br />CONSTRUCTION <br />TYPE <br />STORIES ALLOWED <br />(WITHOUT HT. <br />INCREASE) <br />HEIGHT <br />ALLOWED <br />BASE ALLOWED <br />AREA PER FLOOR <br />(CBC TABLE 506.2.1) <br />PROVIDED <br />AREA <br />RESIDENTIAL A1 & A2 V-A / R-2 4 70 36,000 SF 7,439 SF <br />COMPLIES <br />YES <br />LEVEL 2 RESIDENTIAL A1 & A2 V-A / R-2 4 70 36,000 SF 7,916 SF YES <br />16,340 SF <br />CO <br />M <br />P <br />L <br />I <br />E <br />S <br />SCALE:1/16" = 1'-0" <br />EAST ELEVATION -BLDG. A2 - FSD ANALYISIS 3 <br />SCALE:1/16" = 1'-0" <br />SOUTH ELEVATION -BLDG. A2 -FSD ANALYISIS 4 <br />1. FOR ELEVATIONS THAT ARE NOT INDICATED ON THIS <br />SHEET HAS MORE THAN 30'-0" OF FIRE SEPARATION <br />DISTANCE AND MEETS THE REQUIREMENT OF CBC 705.8.1 <br />EXCEPTION #2 <br />2. BUILDINGS WHOSE EXTERIOR BEARING WALLS, EXTERIOR <br />NONBEARING WALLS AND EXTERIOR PRIMARY STRUCTURAL <br />FRAME ARE NOT REQUIRED TO BE FIRE-RESISTANCE RATED <br />SHALL BE PERMITTED TO HAVE UNLIMITED UNPROTECTED <br />OPENINGS <br />NOTES: <br />A <br />PLUMBING FIXTURE JUSTIFICATION CPC TABLE 422.0 <br />TABLE 4-1 OCCUPANT LOAD FACTOR: <br />ASSEMBLY - W/O FIXED SEATING: 147 SF NET / 30 = 4.9 OR 5 OCC. <br />BUSINESS: 113 SF NET / 150 = 0.75 OR 2 OCC. <br />KITCHEN: 46 SF NET / 50 = 0.92 OR 1 OCC. <br />STORAGE: 67 SF NET / 4000 = 0.017 OR 1 OCC. <br />TOTAL OCC. LOAD = 9 OCC. <br />TABLE 422.1 MINIMUM PLUMBING FACILITIES: <br />PER CPC SECTION 422.2 SEPARATE FACILITIES, EXCEPTION #2, IN OCCUPANCIES WITH A <br />TOTAL OCCUPANT LOAD OF 10 OR LESS, INCLUDING CUSTOMERS AND EMPLOYEES, ONE <br />TOILET FACILITY, DESIGNED FOR USE BY NO MORE THAN ONE PERSON AT A TIME, SHALL BE <br />PERMITED FOR USE BY BOTH SEXES. <br />A <br />B 635 SF <br />150 5 <br />ASSEMBLY <br />LEVEL 1 ASSEMBLY A1 V-A / B 704 54,000 SF 771 SF YES <br />NON SEPARATED OCCUPANCIES <br />CBC 508.3.2 ALLOWABLE BUILDING AREA <br />16,340 SF < 34,500 SF ------------------> COMPLIES <br />B: COMMUNITY ROOM <br />A <br />A <br />B 131 SF <br />150 1 <br />ASSEMBLY <br />LAUNDRY - INCIDENTAL USE (CBC 509.1) <br />NFPA 13 - NO RATING REQUIRED <br />ASSEMBLY LISTED AS B (CBC 303.1.2) <br />ASSEMBLY LISTED AS B (CBC 303.1.2) <br />A <br />1. ALL INTERIOR WALL AND CEILING FINISHES SHALL COMPLY WITH MIN. FLAME SPREAD/SMOKE INDEX PER 2022 CBC 803.13 (PER <br />ASTM E 84 FLAME SPREAD/ SMOKE INDEX OF GYP BOARD, STUCCO, CMU, AND BATHROOM WALL TILE ARE ALL CLASS A) <br />2. ALL INTERIOR WALL AND CEILING FINISHES SHALL COMPLY WITH C.B.C. CHAPTER 8 AND TITLE 24. CCR FOR MAXIMUM ALLOWABLE <br />FLAME SPREAD RATING. <br />MIN. FLAME SPREAD CLASS (SEE ADJACENT PLANS FOR LOCATIONS) <br />INTERIOR WALL AND CEILING FINISHES CBC TABLE 803.13 <br />A <br />FLAME SPREAD/SMOKE DEVELOPMENT CLASS REFRENCE: <br />A = 0-25 FLAME SPREAD INDEX/ 450 SMOKE DEV INDEX <br />B = 26-75 FLAME SPREAD INDEX/ 450 SMOKE DEV INDEX <br />C = 76-200 FLAME SPREAD INDEX/ 450 SMOKE DEV INDEX <br />FLAME SPREAD/SMOKE DEVELOPMENT CLASS REFRENCE: <br />A = 0-25 FLAME SPREAD INDEX/ 450 SMOKE DEV INDEX <br />B = 26-75 FLAME SPREAD INDEX/ 450 SMOKE DEV INDEX <br />C = 76-200 FLAME SPREAD INDEX/ 450 SMOKE DEV INDEX <br />3. ANY WALL/CEILING FINISHES SELECTED BY CONTRACTOR, OWNER, OR INTERIOR DESIGNER THAT DIFFER FROM FINISH BUILDING <br />MATERIALS SHOWN ABOVE, MUST COMPLY WITH THE MIN. FLAME SPREAD/SMOKE INDEX AS REQ'D PER 2019 CBC TABLE 803.13 AND <br />MUST BE SUBMITTED, BY THE CONTRACTOR, TO THE BUILDING AUTHORITY FOR APPROVAL. <br />4. ALL FLOORING MATERIALS MUST COMPLY WITH 2022 CBC SECTION 804 (RADIANT FLUX). ANY FINISHES SELECTED BY CONTRACTOR, <br />OWNER, OR INTERIOR DESIGNER THAT DIFFER FROM THOSE SHOWN ABOVE, MUST BE SUBMITED TO BLD DPT AND FIRE DPT FOR <br />APPROVAL <br />OCCUPANCY CLASS MIN. FLAME <br />SPREAD/SMOKE <br />DEVELOPMENT CLASS <br />X X <br />R-2 C <br />UNIT OPEN CORRIDOR <br />R-2 C <br />B C <br />COMMUNITY ROOM <br />LAUNDRY ROOM <br />B C <br />TRASH <br />NO <br />R <br />T <br />H <br />NO <br />R <br />T <br />H <br />A <br />B <br />U: UTILITY <br />* ACCESSORY OCCUPANCY PER CBC 508.2 AGGREGATE AREA IS LESS THAN 10% OF THE FLOOR AREA OF THE STORY IN WHICH <br />THEY ARE LOCATED AND SHALL NOT EXCEED THE TABULAR VALUES FOR NON SPRINKLERED BUILDINGS IN TABLE 506.2 FOR THE <br />ACCESSORY STRUCTURE. <br />B <br />TYPICAL CONDITIONED SPACE @ EACH UNIT ON FL 1: 750 SF <br />TYPICAL CONDITIONED SPACE @ EACH UNIT ON FL 2: 775 SF <br />C <br />C <br />LEVEL 1 TRASH <br />ENCLOSURE -V-A / U 4 70 36,000 SF 214 SF YES <br />C <br />C <br />C <br />C <br />A PC COMMENTS RESPONSE #1 01/29/2025 <br />B PC COMMENTS RESPONSE #2 04/17/2025 <br />C PC COMMENTS RESPONSE #3 07/08/2025