My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1851 E 1st St Unit #600 & 640 - Plan
PBA
>
Building
>
ProjectDox
>
F
>
First St
>
1851 E First St Unit# 600
>
1851 E 1st St Unit #600 & 640 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/15/2026 5:00:12 AM
Creation date
1/15/2026 5:00:04 AM
Metadata
Fields
Template:
Plan
Permit Number
101124866
101124867
Full Address
1851 E First St Unit# 600
1851 E First St Unit# 640
Street Number
1851
Street Direction
E
Street Name
First
Street Suffix
St
Unit Number
640
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Plannin <br />IAV- <br />ncyI <br />Pon <br />J <br />C� <br />G <br />11 <br />F. <br />No <br />11 10 9 8 7 6 5 4 3.5 3 2 1.3 1.1 1 <br />I I I I I I I I I I I I I <br />I I I I I SUITE 600 ! I I <br />PROJECT <br />NORTH <br />1/8"=1'-0" <br />NEI <br />0 8 16 32 <br />CONTRACTOR TO VERIFY SITE CONDITIONS <br />PRIOR TO PRICING. <br />NOTE: <br />CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL <br />EXISTING FIELD CONDITIONS. CONTRACTOR WILL NOTIFY <br />SPACES IMMEDIATELY AS TO ANY DISCREPANCIES BETWEEN <br />FIELD CONDITIONS AND WORKING DRAWINGS. <br />SPACES'S DESIGN AND CONSTRUCTION DRAWINGS HAVE BEEN DESIGNED TO SUBSTANTIALLY <br />CONFORM TO CALIFORNIA TITLE 24 ACCESSIBILITY CODES. ANY TENANT MODIFICATIONS TO <br />THESE DRAWINGS WILL BE THE TENANT'S LIABILITY. DURING THE TENANT'S OCCUPANCY OF <br />THE SPACE, THE TENANT WILL BE RESPONSIBLE TO PROVIDE REASONABLE ACCOMMODATION <br />TO INDIVIDUAL EMPLOYEES BASED UPON CALIFORNIA TITLE 24 ACCESSIBILITY CODES. ANY <br />DEVIATION BY THE TENANT FROM CALIFORNIA TITLE 24 ACCESSIBILITY CODES WILL BE THE <br />TENANT'S SOLE RESPONSIBILITY AND LIABILITY. NEITHER SPACES/ARCHITECT NOR THE <br />CONTRACTOR WILL BE LIABLE FOR ANY TENANT DEVIATIONS. <br />OCCUPANT LOAD INFORMATION <br />MAXIMUM OCCUPANT LOAD & <br />LOAD FACTOR FOR INDIVIDUAL ROOMS <br />ROOM # <br />S.F. <br />OCC. LOAD FACTOR <br />MAX OCC. LOAD <br />PER ROOM <br />EXISTING RECEPTION 640 <br />241 <br />15 <br />16 <br />EXISTING CONFERENCE 641 <br />250 <br />15 <br />17 <br />EXISTING OFFICE 642 <br />327 <br />150 <br />2 <br />EXISTING OFFICE 643 <br />192 <br />150 <br />1 <br />EXISTING OFFICE 644 <br />190 <br />150 <br />1 <br />EXISTING OFFICE 645 <br />201 <br />150 <br />1 <br />EXISTING OFFICE 646 <br />260 <br />150 <br />2 <br />EXISTING OPEN OFFICE 647 <br />204 <br />150 <br />1 <br />EXISTING OPEN OFFICE 648 <br />315 <br />150 <br />2 <br />EXISTING OPEN OFFICE 649 <br />525 <br />150 <br />4 <br />EXISTING TELCO 650 <br />147 <br />300 <br />1 <br />EXISTING BREAK 651 <br />128 <br />15 <br />9 <br />NEW OPEN OFFICE 652 <br />549 <br />150 <br />4 <br />NEW OFFICE 653 <br />147 <br />150 <br />1 <br />NEW OFFICE 654 <br />150 <br />150 <br />1 <br />NEW OFFICE 655 <br />126 <br />150 <br />1 <br />NEW OFFICE 656 <br />129 <br />150 <br />1 <br />PASS WAY 1 <br />59 <br />N/A <br />N/A <br />TOTAL= 65 <br />OCCUPANT LOAD OF EACH ROOM OR AREA IS BASED ON 2022 C.B.0 <br />SECTION 1004 AND TABLE 1004.5. SEE C.B.C. TABLE 1006.2.1 <br />FOR SPACES WITH ONE MEANS OF EGRESS BASED ON MAXIMUM <br />OCCUPANT LOAD. <br />NOTE: <br />TACTILE EXIT SIGNAGE TO COMPLY, PER 2022 C.B.C. SECTION 1013. SEE A-4 <br />FOR DETAILS. REFER TO A-2 FOR EMERGENCY NIGHT LIGHT AND EXIT SIGN <br />LOCATIONS, PER 2022 C.B.C. SECTIONS 1008 & 1009. <br />(SPRINKLERED BUILDING) <br />MAX. COMMON PATH IS 100 FEET <br />MAX. EXIT PATH IS 300 FEET <br />OCCUPANT LOAD FOR SUITE 640 (FOR B OCCUPANCY <br />4,486 S.F., REQUIRES TWO (2) EXIT. THREE (3) EXIT IS PROVIDED. <br />EGRESS NOTES: <br />1. THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALL NORMALLY BE PROVIDED BY THE <br />PREMISES ELECTRICAL SUPPLY, PER 2022 C.B.C. 1008.3. <br />2. IN THE EVENT OF POWER SUPPLY FAILURE IN ROOMS AND SPACES THAT REQUIRE TWO OR MORE <br />MEANS OF EGRESS, AN EMERGENCY ELECTRICAL SYSTEM SHALL AUTOMATICALLY ILLUMINATE ALL OF <br />THE FOLLOWING AREAS: AISLES, CORRIDORS, EXIT ACCESS STAIRWAYS AND RAMPS, PER 2022 C.B.C. <br />1008.3 & 1008.3.1 THROUGH 1008.3.5. <br />3. LANDINGS SHALL HAVE A WIDTH NOT LESS THEN THE WIDTH OF THE STAIRWAY OR THE DOOR, <br />WHICHEVER IS GREATER. DOORS IN THE FULLY OPEN POSITION SHALL NOT REDUCE A REQUIRED <br />DIMENSION BY MORE THAN 7 INCHES. WHERE A LANDING SERVES AN OCCUPANT LOAD OF 50 OR MORE, <br />DOORS IN ANY POSITION SHALL NOT REDUCE THE LANDING TO LESS THAN ONE—HALF ITS REQUIRED <br />WIDTH. LANDINGS SHALL HAVE A LENGTH MEASURED IN THE DIRECTION OF TRAVEL OF NOT LESS THAN <br />44 INCHES, PER 2022 C.B.C. 1010.1.6. <br />4. EXITS SHALL DISCHARGE DIRECTLY TO THE EXTERIOR OF THE BUILDING. THE EXIT DISCHARGE SHALL BE <br />AT GRADE OR SHALL PROVIDE A DIRECT PATH OF EGRESS TRAVEL TO GRADE. THE EXIT DISCHARGE <br />SHALL NOT REENTER A BUILDING, PER 2022 C.B.C. 1028.2. <br />5. APPROVED EXIT SIGNS SHALL BE LOCATED AS NECESSARY TO CLEARLY INDICATE THE DIRECTION OF <br />EGRESS TRAVEL AS REQUIRED BY CALIFORNIA BUILDING CODE 1013.1; AND SHALL BE INTERNALLY OR <br />EXTERNALLY ILLUMINATED AS REQUIRED BY SECTION 1013.3 IN ACCORDANCE WITH THE PROVISIONS SET <br />FORTH IN SECTIONS 1013.5 AND NOTE: ADDITIONAL EXIT SIGNS MAY BE REQUIRED AT TIME OF <br />FIELD INSPECTION. <br />EGRESS PLAN LEGEND <br />COMMON PATH <br />- - - EXIT PATH <br />FA TACTILE EXIT SIGN <br />® 2'x4' LED LIGHT FIXTURE W/ NIGHTLIGHT <br />ILLUMINATED EXIT SIGN <br />FE FIRE EXTINGUISHER <br />FOR P <br />Master <br />_'44. <br />Date: <br />SEE SHEET A-4 FOR DETAILS <br />OANICE <br />v v • <br />Santa Ana, Ca. 92705 <br />TENANT <br />fl <br />AREA SQUARE FOOTAGE <br />EXISTING 640: 3,298 TOTAL SF <br />EXPANDED 640: 4,486 TOTAL <br />EXISTING 600: 5,480 TOTAL SF <br />REDUCED 600: 4,292 TOTAL SF <br />THESE DRAWINGS AND/OR THE ACCOMPANING SPECIFICATIONS AS INSTRUMENTS <br />OF SERVICE, ARE THE EXCLUSIVE PROPERTY OF SPACES AND THEIR USE AND <br />PUBLICATION SHALL BE RESTRICTED TO THE ORIGINAL SPACE OR SUITE FOR <br />WHICH THEY WERE PREPARED. RE -USE, REPRODUCTION, OR PUBLICATION BY <br />ANY MEMOD, IN WHOLE OR IN PART IS PROHIBITED EXCEPT BY WRITTEN PER- <br />MISSION FROM SPACES. TITLE TO THESE PLANS AND/OR SPECIFICATIONS SHALL <br />REMAIN SPACES WITHOUT PREJUDICE, AND VISUAL CONTACT WITH THEM SHALL <br />CONSTITUTE PRIMA FACIA EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. <br />PRESCREEN CORRECTIONS 10.08.25 <br />SUBMIT TO 09.15.25 <br />RELEASED TO 09.03.25 <br />NO. DESCRIPTION DATE <br />REVISIONS <br />COMMERCIAL INTERIORS <br />■ <br />Elmo *A <br />■■■ "Mral <br />PLANNING & DESIGN <br />3150 BRISTOL, STE 205 1 COSTA MESA, CA 92626 <br />949.724.1499 1 www.spaces—oc.com <br />DRAWN <br />o ■CALIFORNIA COUNCIL FOR --I <br />6 <br />U <br />U <br />O <br />ip.r-G�, <br />o DATE <br />y 09.02.25 <br />G'! <br />= CHECKED <br />A RPti <br />PRINT DATE <br />= 80J 1ION000 vINNOJI1v0■ =109.10.25 <br />SIXTH <br />FLOOR <br />EGRESS <br />PLAN <br />Sheet Title <br />Project Number 2068.928 <br />Sheet Number EG-1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.