LEGEND <br />2' x 2' ACOUSTICAL TILE & GRID, U.O.N. <br />SEE SPEC #1 <br />ncyI <br />�A} <br />CJ� - <br />D `1I <br />c� <br />z <br />LUx <br />w <br />L�- <br />F.5 <br />1 1 10 9 8 7 6 5 4 3.5 3 2 1.3 1 .1 1 <br />I I I I I I I I I I I I I <br />I I I I SUITE 600 I I <br />PROJECT <br />NORTH <br />1/8"=1'-0" <br />0 8 16 32 <br />CONTRACTOR TO VERIFY SITE CONDITIONS <br />PRIOR TO PRICING. <br />NOTE: <br />CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL <br />EXISTING FIELD CONDITIONS. CONTRACTOR WILL NOTIFY <br />SPACES IMMEDIATELY AS TO ANY DISCREPANCIES BETWEEN <br />FIELD CONDITIONS AND WORKING DRAWINGS. <br />SPACES'S DESIGN AND CONSTRUCTION DRAWINGS HAVE BEEN DESIGNED TO SUBSTANTIALLY <br />CONFORM TO CALIFORNIA TITLE 24 ACCESSIBILITY CODES. ANY TENANT MODIFICATIONS TO <br />THESE DRAWINGS WILL BE THE TENANT'S LIABILITY. DURING THE TENANT'S OCCUPANCY OF <br />THE SPACE, THE TENANT WILL BE RESPONSIBLE TO PROVIDE REASONABLE ACCOMMODATION <br />TO INDIVIDUAL EMPLOYEES BASED UPON CALIFORNIA TITLE 24 ACCESSIBILITY CODES. ANY <br />DEVIATION BY THE TENANT FROM CALIFORNIA TITLE 24 ACCESSIBILITY CODES WILL BE THE <br />TENANT'S SOLE RESPONSIBILITY AND LIABILITY. NEITHER SPACES/ARCHITECT NOR THE <br />CONTRACTOR WILL BE LIABLE FOR ANY TENANT DEVIATIONS. <br />A-2 KEY NOTES <br />8 EXISTING/NEW EXIT SIGN: LITHONIA LIGHTING EDGE -LIT "PRECISE COLLECTION" <br />LRP 2 GMR DA �39 COLOR: GREEN <br />K2 ALL MEETING AND CONFERENCE ROOMS TO BE ON SEPARATE ZONE/VAV BOX/T-STAT. <br />(EXISTING, MECHANICAL ENGINEER TO VERIFY) <br />K3 ALL OUTLETS/PLATES AND SWITCHES/PLATES TO BE WHITE, COLOR TO BE UNIFORM <br />THROUGHOUT SUITE. PROVIDE NEW AS NEEDED, AND REPLACE EXISTING AS REQUIRED. <br />K4 RE -SWITCHED LIGHTS IN OPEN OFFICE AREA AT EXPANSION AREA. <br />K5 PROVIDE NEW SLEEVE IN BUILDING TELEPHONE/ELECTRICAL ROOM FOR WIRING OF NEW <br />LIGHTING CONTROLS. (EXISTING) <br />K6 SUITE TO BE ENGINEERED MEET 2022 C.B.C.-TITLE 24; <br />LIGHT FIXTURES TO BE DAY LIGHTING AND DIMMABLE WITH OCCUPANT SENSORS WITH NEW <br />CONTROLS IN EXPANSION AREA. <br />K7 RELOCATE AND/OR ADD/SUBTRACT FIRE SPRINKLERS PER SUITE LAYOUT IN EXPANSION <br />AREA. <br />K8 EXISTING CEILING GRID TO REMAIN, IF NEW CEILING TILES ARE NEEDED; ARMSTRONG <br />DUNE. CEILING TILES TO MATCH EXISTING SUITE, REPLACE AS NEEDED IN EXPANSION <br />AREA. <br />K9 CLEAN OR RE -PAINT ALL HVAC SUPPLY AND RETURN GRILLS THAT ARE RE -USED IN <br />EXPANSION AREA. <br />K10 REWORK GRID AT HATCHED AREA PRIOR TO INSTALLING NEW CEILING TILES. <br />2022 TITLE 24: <br />LIGHTING CONTROL ACCEPTANCE REQUIREMENTS PER 130.4. A CERTIFICATE OF <br />ACCEPTANCE SHALL BE SUBMITTED TO THE ENFORCEMENT AGENCY UNDER SECTION <br />10-103(A) OF PART 1 FOR: <br />A. AUTOMATIC DAYLIGHT CONTROLS <br />B. LIGHTING CONTROLS <br />C. DEMAND RESPONSIVE CONTROLS <br />SUITE 635 <br />BUILDING STANDARD NOTES <br />FIRE LIFE SAFETY: <br />16. ALL LIGHTING, FIRE LIFE SAFETY, AND VENTILATION SHALL COMPLY WITH CURRENT BUILDING CODES. <br />17. ALL FIRE LIFE SAFETY, TITLE 24 REQUIREMENT COMPLIANCE MUST BE INCLUDED IN BID. ELECTRICAL <br />ENGINEER/SUBCONTRACTOR IS RESPONSIBLE FOR FIRE LIFE SAFETY ENGINEERING AND BUILD -OUT, <br />EXCLUDING SPRINKLERS. <br />18. "EXIT" SIGNS SHALL BE PROVIDED IN ACCORDANCE WITH 2O22 C.B.C., CHAPTER 10, SECTIONS 1011. <br />19. INSTALL NEW/RELOCATE EXISTING EXIT SIGNS, FIRE LIFE SAFETY SPEAKERS, STROBES, NIGHT LIGHTS, <br />AND SMOKE DETECTORS AS REQUIRED BY CURRENT BUILDING CODES. NEW TO MATCH EXISTING, <br />U.O.N. VERIFY IF EXISTING SPEAKERS (IF ANY) ARE REGULAR OR FIRE LIFE SAFETY. <br />SEE ENGINEERING PLANS FOR FINAL LOCATIONS AND SPECIFICATIONS. <br />20. IF REQUIRED, G.C. TO ADD/CHANGE OUT ALL EXISTING SPEAKER/STROBES WITH NEW BUILDING <br />STANDARD. G.C. TO VERIFY REQUIREMENT WITH CITY OF SANTA ANA & OBTAIN APPROVAL FROM <br />BUILDING OWNER. SEE SPEC'S #4. 5 & 6. <br />21. 2013 C.B.C. EXCEPTION 4 (SEE NOTE #16 & 27/A-0) WILL BE USED IN AREA AS SHOWN. THE <br />BUILDING IS EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM THROUGHOUT. SMOKE DETECTORS <br />WILL BE INSTALLED WITHIN THE CORRIDOR IN ACCORDANCE WITH THEIR LISTINGS. SEE FIRE LIFE <br />SAFETY PLAN FOR SMOKE DETECTOR LOCATIONS. <br />22. RELOCATE SPRINKLERS IF/AS REQUIRED. INSTALL PER CITY OF SANTA ANA FIRE CODE. <br />23. PLANS SHALL INDICATE HOW REQUIRED STRUCTURAL AND FIRE RESISTIVE INTEGRITY WILL BE <br />MAINTAINED WHERE A PENETRATION WILL BE MADE IN RATED WALLS FOR ELECTRICAL, MECHANICAL, <br />PLUMBING AND COMMUNICATION CONDUITS, PIPES, AND SIMILAR SYSTEMS. SEE 2022 C.B.C. <br />CHAPTER 7, SECTION 714 NOTE ON THE PLANS THE ICC RESEARCH REPORT NUMBER, U.L. <br />NUMBER, STATE FIRE MARSHAL NUMBER, OR APPROVAL NUMBER OF ANOTHER AGENCY ACCEPTED <br />BY THE CITY OF SANTA ANA. <br />SWITCHES, MOTION SENSORS, HVAC, ETC.: <br />24. THE CENTERLINE OF NEW SWITCHES AND WALL MOUNTED MOTION DETECTORS TO BE LOCATED NOT <br />MORE THAN 8" FROM DOOR FRAME WHERE INDICATED AND PRACTICAL. ALL OTHERS TO BE MOUNTED <br />ON THE WALL THAT THE DOOR SWINGS TO, SPACED 4" AWAY FROM EDGE OF DOOR SWING. U.O.N. <br />SENSORS & SWITCHES TO BE MOUNTED AT 42" A.F.F. <br />25. PROVIDE CEILING MOTION DETECTORS AS SHOWN AND PROVIDE NEW AS NEEDED. <br />26. RETURN EXCESS / DEMO LIGHT FIXTURES AND CEILING MOUNTED MOTION SENSORS TO BUILDING <br />STOCK, U.O.N. <br />27. GANG LIGHTING IN OPEN OFFICES AND PASSAGEWAYS OF SUITE. PROVIDE CEILING MOTION SENSORS <br />AS NEEDED, AND OVERRIDE SWITCHES AT EACH EXIT (IF NOT EXISTING). <br />28. SEE MECHANICAL ENGINEERING PLANS FOR LOCATIONS AND SPECIFICATIONS OF HVAC SUPPLY AND <br />RETURN AIR VENTS AND DUCTING (EXISTING BUT NOT SHOWN ON ARCHITECTURAL PLANS). <br />29. G.C. TO CLEAN & REPAIR EXISTING SUPPLY AND RETURN AIR GRILLS, AND REPAIR DUCTS AS <br />REQUIRED. SEE MECHANICAL ENGINEERING PLANS. <br />30. PROVIDE NATURAL VENTILATION (PER SECTION 1203.4 OF THE 2022 C.B.C.) OR MECHANICAL <br />VENTILATION (PER CALIFORNIA MECHANICAL CODE) AS REQUIRED. PROVIDE NATURAL OR ARTIFICIAL <br />LIGHTING PER SECTION 1205 OF 2022 C.B.C. <br />31. ALL ENCLOSED PORTIONS OF BUILDINGS CUSTOMARILY OCCUPIED BY HUMAN BEINGS SHALL BE <br />PROVIDED WITH A NATURAL OR MECHANICAL VENTILATION SYSTEM. MECHANICALLY OPERATED <br />VENTILATION SYSTEMS SHALL BE CAPABLE OF SUPPLYING A MINIMUM OF 5 CUBIC FEET PER MINUTE <br />(OR AS REQUIRED PER 2022 C.M.C.) OF OUTSIDE AIR PER OCCUPANT DURING SUCH TIME AS THE <br />BUILDING IS OCCUPIED. IF THE VELOCITY OF AIR AT A REGISTER EXCEEDS 10 FEET PER SECOND, <br />THE REGISTER SHALL BE PLACED MORE THAN 8 FEET ABOVE THE FLOOR DIRECTLY BENEATH. [SEE <br />NOTES 22 & 23 ON SHEET A-0 FOR ADDITIONAL HVAC CODE NOTES.] <br />SUITE 630 <br />GENERAL: <br />1. VERIFYING EXISTING CONDITIONS - BEFORE SUBMITTING BID, G.C. SHALL BECOME <br />THOROUGHLY FAMILIAR WITH ACTUAL EXISTING CONDITIONS AT THE BUILDING. THE <br />INTENT OF THE WORK IS SHOWN ON THE DRAWINGS AND DESCRIBED HEREINAFTER. <br />BY THE ACT OF SUBMITTING A BID PROPOSAL FOR WORK, THE CONTRACTOR SHALL <br />BE DEEMED TO HAVE MADE SUCH A STUDY AND EXAMINATION AND TO ACCEPT ALL <br />CONDITIONS PRESENT AT THE SITE. NO REQUEST FOR ADDITIONAL PAYMENT SHALL <br />BE CONSIDERED VALID, DUE TO FAILURE TO ALLOW FOR CONDITIONS WHICH MAY <br />EXIST. <br />2. ALL SUBCONTRACTORS SHALL BE CITY AND STATE LICENSED. <br />3. ALL ARCHITECTURAL AND ENGINEERING DOCUMENTS TO BE PRODUCED ON AUTOCAD. <br />PROPERTY MANAGER/ENGINEERS TO RECEIVE A COPY OF THE COMPLETED DISCS. <br />4. ALL EXISTING HANDICAPPED FACILITIES SHALL MEET OR COMPLY WITH TITLE 24 <br />HANDICAPPED ACCESSIBILITY REQUIREMENTS, INCLUDING HEIGHT OF SWITCHES. <br />5. G.C. TO VERIFY HVAC CONDITIONS/ZONING WITH BUILDING ENGINEER TO ENSURE <br />ADEQUACY OF EXISTING UNITS FOR SUITE. ANY ADDITIONS TO HVAC EQUIPMENT <br />SHALL BE INCLUDED IN SCOPE AND BID FOR PROPOSED WORK. <br />6. G.C. TO VERIFY CAPACITY OF EXISTING ELECTRICAL PANEL/ TRANSFORMERS IS <br />ADEQUATE FOR PROPOSED WORK. IF ANY ADDITIONS TO ELECTRICAL CAPACITY OF <br />BUILDING IS REQUIRED IT SHALL BE INCLUDED IN SCOPE AND BID FOR PROPOSED <br />WORK. <br />7. SEPARATE MECHANICAL, HVAC, ELECTRICAL, AND FIRE LIFE SAFETY IN THIS SUITE FROM THAT <br />OF ADJACENT SUITES, AND COMBINE WITHIN SUITE, IF NOT ALREADY. <br />8. ALL ENGINEERING TO BE DESIGN/BUILD SUITES. <br />GRID, TILES, LIGHTS: <br />9. ALL SUSPENDED T-BAR IS EXISTING TO REMAIN, U.O.N. MODIFY AS NEEDED AT <br />CONSTRUCTION. REPAIR GRID AS REQUIRED TO OBTAIN A CONTINUOUS, UNIFORM, <br />AS -NEW APPEARANCE THROUGHOUT SUITE. SEE PARTITION & DEMO PLANS AND <br />SPEC #1. <br />10. ALL ACOUSTICAL CEILING TILES ARE EXISTING TO REMAIN, U.O.N. MODIFY AS NEEDED <br />AT CONSTRUCTION. TRIM/PATCH/REPLACE TILES AS REQUIRED TO OBTAIN A <br />CONTINUOUS, UNIFORM, AS -NEW APPEARANCE THROUGHOUT SUITE. <br />11. LIGHT FIXTURES ARE NEW LED, U.O.N. G.C. TO ALLOW FOR MINIMUM LIGHT LEVEL <br />OF ONE (1) FIXTURE PER EIGHTY (80) SQUARE FEET U.O.N. <br />ALL LIGHTING TO BE CONNECTED TO BASE BLDG. ENERGY MGT. SYSTEM. <br />12. G.C. TO PROVIDE NIGHT LIGHTS. <br />13. WHERE WALLS HAVE BEEN DEMOLISHED OR NEW CEILING GRIDS ADDED, REINFORCE <br />NEW CEILING GRID WITH COMPRESSION STRUTS AS REQUIRED PER CURRENT CODES, <br />SEE REQUIREMENTS IN CEILING DETAILS #11 & 17/8-5. <br />14. PROVIDE BRACING AT CEILING AND TIE WIRES AT FIXTURES TO MEET <br />CBC/BOCA/LOCAL CODES. CONFIRM EXISTING CONDITIONS. <br />15. SPARE. <br />2' X 4' LED LIGHT FIXTURE <br />® <br />2 X 4 LED LIGHT FIXTURE (NIGHT LIGHT) <br />�________, <br />IIER -'��/ II <br />EXISTING 2' X 4' LIGHT FIXTURE TO BE DEMO'D <br />OR <br />P <br />.- <br />DOUBLE TOGGLE DIMMABLE OVERRIDE SWITCH <br />FOR CEILING SENSORS <br />WALL MOUNTED MOTION SENSOR WITH INTEGRAL <br />WITH DIMMABLE OVERRIDE SWITCH <br />2-WAY CEILING MOUNTED MOTION DETECTOR <br />Master <br />I[ <br />1-WAY CEILING MOUNTED MOTION DETECTOR <br />® <br />AREA OF CEILING GRID REPAIR <br />F)ate. <br />PLEASE <br />REFER TO FIRE LIFE SAFETY NOTES: #16-22 <br />& SEE <br />FIRE LIFE <br />SAFETY/ENGINEERING PLANS FOR FINAL <br />LOCATIONS. <br />I(> <br />EXIT SIGN <br />SEE <br />SPEC #3 <br />SD <br />SMOKE DETECTOR <br />SEE <br />SPEC #7 <br />O <br />LIFE SAFETY SPEAKERS <br />SEE <br />SPEC #4 <br />ST <br />FIRE STROBE <br />SEE <br />SPEC #6 <br />D DEMO <br />E EXISTING <br />N NEW <br />1 <br />ER EXISTING TO RELOCATED <br />R RELOCATED <br />TYP. TYPICAL THROUGHOUT SUITE <br />ALL ITEMS <br />ARE EXISTING TO REMAIN, UNLESS <br />OTHERWISE <br />NOTED. <br />SPECIFICATIONS <br />LIGHT FIXTURES AND LIGHT CONTROLS TO COMPLY WITH 2O19 CALIFORNIA ELECTRIC CODE/TITLE <br />24 ENERGY REQUIREMENTS AS NEEDED PER SCOPE OF WORK. <br />A-2 IS FOR GENERAL LIGHT LAYOUT ONLY: SEE ELECTRICAL ENGINEERING DRAWINGS FOR SPECIFIC <br />CHANGES REQUIRED PER SCOPE OF WORK AND FOR ROOM CONTROLLERS, WALL STATION <br />CONTROLS, DAYLIGHT AND MOTION SENSOR LOCATIONS, SPECS AND SYSTEM CONNECTIONS. <br />1. PRIMARY CEILING TILE & GRID (G.C. TO VERIFY SPECS ARE CURRENT): <br />• TILES: NEW LEED SPEC IS ARMSTRONG, DUNE, 9/16" BEVELED TEGULAR #1775 OR <br />W1775HRC (HIGH RECYCLED CONTENT) 24" x 24" x 5/8" TILES [TO MATCH OLD CELOTEX <br />TILES (IN SIZE AND PROFILE) AND WORK WITH EXISTING TEMPRA 2'x 2" GRID.] <br />• CEILING GRID: CHICAGO METALIC CORP. "TEMPRA" 4000 SERIES, 9/16" 2' x 2' GRID <br />[2 FOOT TEE'S 9/16" FACE WHITE #4012-01; 4 FOOT TEE'S #4014.01 CH; MAIN <br />RUNNER #4000-01.] SUSPENSION SYSTEM SHALL COMPLY WITH ASTM C635 SPECS. <br />SEE CEILING DETAILS ON SHEET A-5 IF NEW GRID IS TO BE INSTALLED. <br />2. (DIMMABLE) LED LIGHT FIXTURES: BUILDING STANDARD, SEE CONTROLLERS & NOTES BELOW. <br />NL DENOTES: NIGHT LIGHT. TO HAVE 90 MINUTE BATTERY BACK-UP. <br />SPEC; LITHONIA, 2AVL4 A 40L MDR MVOLT EZ1 LP840 <br />2X4 RECESSED INDIRECT/DIRECT WITH PERFORATED CENTER BASKET AND AIR RETURN SLOTS <br />3. EXIT SIGN: LITHONIA, EDGE -LIT "PRECISE" COLLECTION, LRP SERIES, GREEN LETTERS, SINGLE/ <br />DOUBLE FACE & DIRECTIONAL ARROWS IF/AS NEEDED PER LOCATION, 120/277 DUAL VOLTAGE. <br />4. LIFE SAFETY SPEAKERS: (PROVIDE AS REQ. BY CODES) 4" FLUSH MOUNTED SPEAKERS, TO BE <br />(COMPATIBLE WITH AND) CONNECTED TO THE BASE BUILDING LIFE SAFETY SYSTEM. LOCATION <br />TO BE SPECIFIED BY THE CITY OF SANTA ANA BUILDING DEPT. VERIFY IF SPEC IS PYROTRONIC <br />9070 (ON PREVIOUS PLANS) OR SIEMENS, SE-CW (NEW SPEC SHOWN ON WORK LETTER). <br />5. FIRE SPEAKER/STROBE: (AS NEEDED) SIEMENS, MODEL SE-MC-CW. <br />6. FIRE STROBE: (RELOCATE EXISTING AND/OR ADD NEW AS REQUIRED BY CODES). SIEMANS, <br />MODEL #ZR-MC-CW. <br />7. SMOKE DETECTOR: (PROVIDE AS REQUIRED BY CODES) PYROTRONIC #IL160. STATE FIRE <br />MARSHAL APPROVED. WIRING: #18 TFFM. <br />8. IONIZATION SMOKE DETECTOR: (THROUGHOUT, U.O.N.) SIEMENS, MODEL ILI-1 [WITH SIEMENS <br />DETECTOR BASE MODEL DB-3S (STANDARD) OR MODEL DB-X3RS (RELAY) AS NEEDED.] SPEC <br />PER NATIONAL FAIL SAFE. <br />9. THERMAL DETECTOR: (WHERE REQUIRED) SIEMENS, MODEL IPT-1 [WITH SIEMENS DETECTOR <br />BASE MODEL DB-3S (STANDARD) OR MODEL DB-X3RS (RELAY) AS NEEDED.] SPEC PER <br />NATIONAL FAIL SAFE. <br />10. FIRE SPRINKLERS: COMMON BUILDING TYPE SPRINKLER HEAD IS TYCO TY-B 155 DEGREE, <br />QUICK RESPONSE CHROME SPRINKLERS, WITH CHROME ESCUTCHEONS [PER FIRE PROTECTION <br />SPECIALISTS (714) 635-6500.] <br />11. OTHER FIRE ALARM DEVICES: <br />• MANUAL PULL STATION: SIEMENS, MODEL MSI-10B <br />• RELAY MODULE: SIEMENS, MODEL TRI-R <br />• INTERFACE MODULE (SINGLE): SIEMENS, MODEL TRI-S <br />• INTERFACE MODULE (DUAL): SIEMENS, MODEL TRI-D <br />12. VAV BOXES: SEE MECHANICAL ENGINEERING & BUILDING ENGINEER GLEN CALL FOR SPECS AT <br />VARIOUS LOCATIONS. EXISTING TYPICAL ARE: TRANE, FAN POWERED VAV BOXES AT NORTH <br />FACING ZONE ONLY. TITUS PNEUMATIC VAV BOXES AT INTERIOR ZONES/ALL OTHER LOCATIONS. <br />CONTROLS AND DEVICES <br />BUILDING CONTROLLERS: <br />• 1 QUANTUM CPU WITH Q-MANAGER SERVER PER BUILDING <br />•1 QUANTUM HUB PER FLOOR <br />SUITE CONTROLLERS: <br />MANUFACTURER: LUTRON, "ESN (ENERGI SAVR NODE)" COMPATIBLE WITH "QUANTUM" <br />BUILDING SYSTEM. <br />LIGHTING CONTROLLER: <br />• LUTRON - ENERGI SAVR NODE WITH ECOSYSTEM (QSM-XECO-S) <br />*LUTRON - QS SENSOR MODULE (QSM2-XW-C) <br />*LUTRON - ECOSYSTEM TO 0-10V INTERFACE (NI-LMF-2A) <br />AREA CONTROLS - MANUAL SWITCH TO TURN THE LIGHTS ON OR OFF <br />MULTI -LEVEL CONTROLS - MANUAL SWITCH TO DIM OR BRIGHTEN THE LIGHTS <br />• LUTRON - PICO WIRELESS CONTROL, 3 BUTTON WITH RAISE/LOWER (PJ-3BRL-GXX) <br />SHUT-OFF CONTROLS - AUTOMATIC DEVICE TO TURN OFF THE LIGHTS WHEN THE SPACE IS <br />VACATED <br />• LUTRON - WIRELESS CEILING MOUNT SENSOR (LRF2-OCR2B-P-WH) <br />• LUTRON - WIRELESS WALL MOUNT SENSOR (LRF2-OWLB-P-WH) <br />DAYLIGHTING CONTROLS - DEVICE TO SENSE THE AMOUNT OF NATURAL LIGHT COMING FROM A <br />WINDOW OR SKYLIGHT <br />• LUTRON - WIRELESS DAYLIGHT SENSOR (LRF2-DCRB-WH) <br />RECEPTACLE CONTROLLER: <br />• LUTRON - ENERGI SAVR NODE WITH SOFTSWITCH (QSM-4T20-S) <br />*CONTROLLED RECEPTACLE MUST BE GRAY <br />DEVICES: <br />• DUPLEX TYPE 15A - 120V, SPECIFICATION GRADE <br />- NEMA 5 - 15R HUBBELL MODEL 5252-1 <br />• FLUSH FLOOR BOXES - HUBBELL WITH COVERS AS LISTED: <br />-DUPLEX RECEPTACLES - HUBBELL # S3925 <br />-TELEPHONE / SIGNAL - HUBBELL # S2725 <br />-CARPET FLANGES - HUBBELL # S3079 <br />• FIRE RATED POKE - THRU FITTING - RACEWAY COMPONENTS INC. <br />-RECEPTACLE / TELEPHONE - RC700 <br />-DOUBLE DUPLEX - RC900A <br />-TELEPHONE SIGNAL RC900M <br />-FURNITURE FEEDS - RC90OFF <br />TITLE 24 GUIDELINES: <br />SECTION 130.1 - INDOOR LIGHTING CONTROLS THAT SHALL BE INSTALLED <br />a.130.1(A) AREA CONTROLS: MANUAL ON AND OFF SWITCH. <br />b.130.1(B) MULTI -LEVEL CONTROLS: MANUAL SWITCH THAT ADJUST THE BRIGHTNESS OF THE <br />LIGHTS. <br />C.130.1(C) SHUT-OFF CONTROLS: AUTOMATICALLY TURNS OFF THE LIGHT WHEN THE SPACE IS <br />UNOCCUPIED (MAXIMUM SETTING 30 MINUTES). <br />d.130.1(D) DAYLIGHTING CONTROLS: AUTOMATICALLY ADJUST THE BRIGHTNESS OF THE LIGHTS <br />BASED ON THE AMOUNT OF NATURAL LIGHTS FROM THE WINDOW OR SKYLIGHTS. <br />e.130.1(E) DEMAND RESPONSE: AUTOMATICALLY ADJUST THE LIGHTS TO DIM TO A PRESET <br />LEVELED WHEN UTILITY COMPANIES TRIGGER A "FLEX ALERT" (SYSTEM ONLY NEEDS TO BE DR <br />CAPABLE AT THIS TIME). <br />SECTION 130.5 - ELECTRICAL POWER DISTRIBUTION SYSTEM <br />• 130.5(D) CIRCUIT CONTROLS FOR 120-VOLT RECEPTACLES. <br />TENANT IMPROVEMENT: <br />• INSTALL NEW FIXTURES OR MOVE FIXTURES NO WINDOWS: MANDATORY A/B/C/1. <br />• INSTALL NEW FIXTURES OR MOVE FIXTURES ON DAYLIGHT ZONE/ WITH WINDOWS <br />• (>= 24 SQFT WINDOW OR >= 120 WATTS): MANDATORY A/B/C/D/1. <br />• SPACE >= 10,000 SQFT: MANDATORY A/B/C/D/E/1. <br />•RECONFIGURE A SPACE (INSTALL OR REMOVE WALLS): MANDATORY A/B/C/D/E/1. <br />• MODIFICATION IN PLACE (I.E. FLUORESCENT TO FLUORESCENT RETROFIT): MANDATORY A/B/C/D. <br />• ALTERATION (I.E. FLUORESCENT TO LED RETROFIT): MANDATORY A/B/C/D/E/1. <br />LTS INVOLVEMENT: <br />• LTS WILL PERFORM ALL THE TASKS ASSOCIATED WITH SYSTEM DESIGN AND SUBMITTAL <br />PACKAGE, CONTROLS DRAWINGS, SYSTEM COMPONENT INSTALLATION, CONTROL WIRING, <br />COMMISSIONING AND ACCEPTANCE TESTING FOR PERMIT SIGNOFF. LTS WILL CONSULT WITH <br />ELECTRICAL INSTALLER OF THE FIXTURE AND OUTLETS ON WIRING METHODS FOR SEPARATE <br />CONTROL OF EACH ZONE. <br />•LTS VS ELECTRICAL CONTRACTOR - PERFORMING ELECTRICAL WORK FOR TENANT <br />IMPROVEMENTS SCOPE OF WORK. <br />• TI ELECTRICIANS INSTALL ALL NEW FIXTURES, OUTLET INSTALLATION, WIRING OR RE -WIRING TO <br />ACCOMMODATE LOCAL CONTROL OF EXISTING SPACE. <br />*IF SPACE PLAN IS USING EXISTING FIXTURES, LTS RETROFIT WITH 0-10V DIMMING BALLASTS <br />TO DO ALL CONTROL WIRING, CONTROL SYSTEM COMPONENTS, COMMISSIONING, AND <br />ACCEPTANCE TESTING. <br />PROVIDE NEW SLEEVE IN BLD. TELEPHONE/ELECT. ROOM FOR WIRING OF NEW LIGHTING CONTROLS. <br />6ANICE <br />v v • <br />Santa Ana, Ca. 92705 <br />TENANT <br />�l0 <br />M WK161jus <br />AREA SQUARE FOOTAGE <br />EXISTING SUITE 840: 3,298 SQ.FT. <br />EXPANDED SUITE 640: 4,486 SQ.FT. <br />EXISTING SUITE 600: 5,480 SQ.FT. <br />REDUCED SUITE 600: 4.292 SQ.FT. <br />THESE DRAWINGS AND/OR THE ACCOMPANING SPECIFICATIONS AS INSTRUMENTS <br />OF SERVICE, ARE THE EXCLUSIVE PROPERTY OF SPACES AND THEIR USE AND <br />PUBLICATION SHALL BE RESTRICTED TO THE ORIGINAL SPACE OR SUITE FOR <br />WHICH THEY WERE PREPARED. RE -USE, REPRODUCTION, OR PUBLICATION BY <br />ANY MEMOD, IN WHOLE OR IN PART IS PROHIBITED EXCEPT BY WRITTEN PER- <br />MISSION FROM SPACES. TITLE TO THESE PLANS AND/OR SPECIFICATIONS SHALL <br />REMAIN SPACES WITHOUT PREJUDICE, AND VISUAL CONTACT WITH THEM SHALL <br />CONSTITUTE PRIMA FACIA EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. <br />PRESCREEN CORRECTIONS 10.08.25 <br />FSUBMIT TO 09.15.25 <br />PLAN CHECK <br />/ \ RELEASED TO 09.15.25 <br />NO. DESCRIPTION DATE <br />REVISIONS <br />COMMERCIAL INTERIORS <br />■ <br />■ *A <br />■■■ " MTN <br />PLANNING & DESIGN <br />3150 BRISTOL, STE 205 1 COSTA MESA, CA 92626 <br />949.724.1499 1 www.spaces-oc.com <br />DRAWN <br />o ■CALIFORNIA COUNCIL FOR --I <br />_ <br />6 <br />U <br />U <br />0 <br />W <br />ip.r-G�, <br />o DATE <br />y 09.02.25 <br />= CHECKED <br />m <br />A RP <br />PRINT DATE <br />= 80J 1ION000 vINNOJI1v0■ =109.10.25 <br />SIXTH <br />FLOOR <br />DEMO � <br />REFLECTED <br />CEILING PLAN <br />Sheet Title <br />Project Number 2068.956 <br />Sheet Number A-2 <br />