LEGEND
<br />'177 M TELEPHONE BACKBOARD
<br />SEE SPEC #1
<br />ncyI
<br />�A}
<br />CJ� -
<br />D `1I
<br />c�
<br />z
<br />LUx
<br />w
<br />L�-
<br />F.5
<br />1 1 10 9 8 7 6 5 4 3.5 3 2 1.3 1 .1 1
<br />I I I I I I I I I I I I I
<br />I I I I SUITE 600 I I
<br />PROJECT
<br />NORTH
<br />1/8"=1'-0"
<br />0 8 16 32
<br />CONTRACTOR TO VERIFY SITE CONDITIONS
<br />PRIOR TO PRICING.
<br />NOTE:
<br />CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL
<br />EXISTING FIELD CONDITIONS. CONTRACTOR WILL NOTIFY
<br />SPACES IMMEDIATELY AS TO ANY DISCREPANCIES BETWEEN
<br />FIELD CONDITIONS AND WORKING DRAWINGS.
<br />SPACES'S DESIGN AND CONSTRUCTION DRAWINGS HAVE BEEN DESIGNED TO SUBSTANTIALLY
<br />CONFORM TO CALIFORNIA TITLE 24 ACCESSIBILITY CODES. ANY TENANT MODIFICATIONS TO
<br />THESE DRAWINGS WILL BE THE TENANT'S LIABILITY. DURING THE TENANT'S OCCUPANCY OF
<br />THE SPACE, THE TENANT WILL BE RESPONSIBLE TO PROVIDE REASONABLE ACCOMMODATION
<br />TO INDIVIDUAL EMPLOYEES BASED UPON CALIFORNIA TITLE 24 ACCESSIBILITY CODES. ANY
<br />DEVIATION BY THE TENANT FROM CALIFORNIA TITLE 24 ACCESSIBILITY CODES WILL BE THE
<br />TENANT'S SOLE RESPONSIBILITY AND LIABILITY. NEITHER SPACES/ARCHITECT NOR THE
<br />CONTRACTOR WILL BE LIABLE FOR ANY TENANT DEVIATIONS.
<br />LIVE LOADS
<br />�G G.C. TO ENSURE COMPLIANCE WITH C.B.C. SECTION 1607.3.5.:
<br />"LIVE LOADS POSTED. THE LIVE LOADS FOR WHICH EACH FLOOR OR PORTION
<br />THEREOF OF A COMMERCIAL OR INDUSTRIAL BUILDING IS OR HAS BEEN DESIGNED
<br />SHALL HAVE SUCH DESIGN LIVE LOADS CONSPICUOUSLY POSTED BY THE OWNER IN
<br />THAT PART OF EACH STORY IN WHICH THEY APPLY, USING DURABLE METAL SIGNS,
<br />AND IT SHALL BE UNLAWFUL TO REMOVE OR DEFACE SUCH NOTICES. THE
<br />OCCUPANT OF THE BUILDING SHALL BE RESPONSIBLE FOR KEEPING THE ACTUAL
<br />LOAD BELOW THE ALLOWABLE LIMITS."
<br />TO THAT END...
<br />CONTRACTOR SHALL INSTALL A DURABLE PLACARD IN THE FILE/STORAGE ROOM AT
<br />A CONSPICUOUS LOCATION. THE AREA OF THE PLACARD SHALL BE 100 SQ. INCHES
<br />MINIMUM. THE OCCUPANT OF THE SUBJECT PORTION OF THE BUILDING SHALL BE
<br />RESPONSIBLE FOR KEEPING THE ACTUAL LOAD BELOW THE ALLOWABLE LOAD LIMITS
<br />INDICATED ON THE PLACARD. THE PLACARD SHALL INDICATE THE FOLLOWING
<br />INFORMATION:
<br />1. THE OPEN SHELF RACKS SHALL BE 16" DEEP BY 6'-0" HIGH MAXIMUM.
<br />2. NO NEW FILE SYSTEM SHALL BE ADDED TO THE FILE ROOMS IN ADDITION TO
<br />THE LAYOUT SHOWN ON THE ARCHITECTURAL DRAWINGS.
<br />3. THE FILE SYSTEM SHALL NOT BE RELOCATED OR REPLACED WITH HEAVIER
<br />UNITS.
<br />4. NO OTHER HEAVY EQUIPMENT WEIGHING MORE THAN 400 POUNDS SHALL BE
<br />LOCATED IN THIS AREA.
<br />5. NO STORAGE IS ALLOWED ON TOP OF THE FILE SYSTEM.
<br />6. THE LIVE LOAD IN THE OPEN AREA AROUND THE FILING SYSTEMS AND IN ALL
<br />OTHER AREAS SHALL NOT EXCEED 50 POUNDS PER SQUARE FOOT (PSF).
<br />7. ITEMS "1" THROUGH "6" ABOVE MAY BE MODIFIED ONLY AFTER REVIEW AND
<br />APPROVAL BY A LICENSED CIVIL OR STRUCTURAL ENGINEER.
<br />THE PLACARD SHOULD ALSO SHOW THE LAYOUT OF THE FILE SYSTEM AND BOOK
<br />SHELVES AS SHOWN ON THE ARCHITECTURAL DRAWINGS.
<br />THE END USER / TENANT IS RESPONSIBLE FOR ENSURING THAT THE ABOVE
<br />RECOMMENDATIONS ARE FOLLOWED AT ALL TIMES.
<br />SUITE 635
<br />TYPICAL OUTLET DIMENSIONS
<br />NOTE: TWO OR MORE
<br />SWITCHES TO BE
<br />GANGED IN SINGLE
<br />FACEPLATE
<br />6" SWITCH
<br />THERMOSTAT
<br />w
<br />J
<br />m
<br />Of I-
<br />TYP. TELEPHONE JACK
<br />WALL
<br />o
<br />Q PHONE
<br />TYP. DUPLEX OUTLET
<br />I- UJI
<br />ww Q
<br />o-
<br />Ld
<br />0 w CL
<br />o_
<br />00
<br />6" MAX
<br />SUITE 630
<br />A-3 KEY NOTES
<br />8
<br />ALL OUTLETS/PLATES
<br />AND SWITCHES/PLATES TO
<br />BE WHITE, COLOR TO
<br />BE UNIFORM
<br />THROUGHOUT SUITE.
<br />PROVIDE NEW AS NEEDED,
<br />AND REPLACE EXISTING
<br />AS REQUIRED.
<br />K2
<br />WHERE OUTLETS ARE
<br />EXISTING TO REMAIN AND
<br />ARE BELOW 18" O.C.,
<br />MOVE UP TO 18" O.C. PER CODE. REPAIR WALL
<br />WHERE OCCURS.
<br />K3
<br />EXISTING TELEPHONE
<br />BACK BOARD AND 20 AMP
<br />SEPARATE CIRCUITS IN
<br />TELE/DATA
<br />ROOM TO REMAIN. TENANT'S VENDOR TO RUN CABLING INTO EXPANSION
<br />AREA.
<br />U)
<br />DUPLEX WALL
<br />OUTLET
<br />SC
<br />DUPLEX WALL
<br />OUTLET -SEPARATE CIRCUIT
<br />QUADURAPLEX
<br />WALL OUTLET
<br />(MULTI -LINE)
<br />TELEPHONE AND/OR DATA
<br />OUTLET WITH
<br />3/4" CONDUIT, WHITE
<br />FE FIRE EXTINGUISHER
<br />FOR PCf�
<br />SEE SPEC #5
<br />Master I
<br />Date:
<br />D DEMO
<br />E EXISTING
<br />N NEW
<br />ER EXISTING TO RELOCATED
<br />R RELOCATED
<br />TYP. TYPICAL THROUGHOUT SUITE
<br />ALL ITEMS ARE EXISTING TO REMAIN, UNLESS OTHERWISE NOTED./
<br />1
<br />SPECIFICATIONS
<br />1 TELEPHONE BACKBOARD: (EXISTING) 8' X 4' X 3/4" PLYWOOD. INSTALL AND
<br />PAINT TO MATCH WALLS. PROVIDE SEPARATE CIRCUIT OUTLET AND 2" CONDUIT
<br />HOME -RUN TO BASE BUILDING TELEPHONE ROOM. PLYWOOD TO BE OF
<br />FIRE -RETARDANT -TREATED WOOD TO COMPLY WITH C.B.C. SECTION 207.10.
<br />2 SINGLE SINK & FAUCET: (EXISTING)
<br />"JUST" BRAND SINK #US-ADA-1830-A-18, SINGLE ADA COMPLIANT BOWL,
<br />DRAIN LOCATION AS REQUIRED; 18"LONG X 30"WIDE X 5-1/2" DEEP.
<br />18GA TYPE 304 18-8 SSTL. UNDERSIDE IS FULLY UNDERCOATED. TO BE
<br />USED WITH SOLID SURFACES COUNTER TOPS.
<br />"DELTA" BRAND ADA COMPLIANT FAUCET, TRINSIC 9159-DST, CHROME FINISH
<br />J-ADA-35 DRAIN SYSTEM WITH OVERFLOW SYSTEM, AND ADA
<br />COMPLIANT DRAIN INSULATOR KIT #J-ADA-150 OR SIMILAR INSULATION
<br />IF/AS REQUIRED BY CODES.
<br />3� INSTA-HOT: (EXISTING) CHRONOMITE MODEL #SR-30 INSTANTANEOUS HOT
<br />WATER HEATER OR EQUAL IN CABINET BELOW. 277V/ 30 AMP/ 8310 WATTS.
<br />4� GARBAGE DISPOSAL: (EXISTING) IN-SINK-ERATOR BRAND, MODEL: "BADGER 5",
<br />GRAY ENAMEL, 120V, 6.9 AMPS, 60 HZ., 1 /2 H.P. OR EQUAL. PLUMBER IS
<br />TO VERIFY PROPER G.D. INSTALLATION W/SINK.
<br />5 FIRE EXTINGUISHER: (EXISTING) NEW BUILDING STANDARD
<br />TYPICAL CABINET IS WHITE, SEMI -RECESSED STYLE: POTTER ROEMER MODEL
<br />#70-12DV, 3-1/4" DEPTH (WITH LOCK IN PUBLIC CORRIDORS, WITHOUT LOCK
<br />IN SUITES). TYPICAL FIRE EXTINGUISHER IS AMEREX BRAND, 5 LB. DRY
<br />CHEMICAL TYPE, 2A10BC, MODEL #500. BUILDING APPROVED VENDOR: PAUL
<br />FIRE DOCTOR (714) 544-4390. QUANTITY & LOCATIONS OF EXTINGUISHERS TO
<br />BE VERIFIED WITH THE CITY OF SANTA ANA BUILDING INSPECTOR AND THE
<br />ARCHITECT PRIOR TO INSTALLATION. NEW TO MATCH BUILDING STD. U.O.N.
<br />DISHWASHER: EXISTING
<br />REFRIGERATOR: EXISTING
<br />MICROWAVE: EXISTING
<br />9� COPIER: EXISTING
<br />10 SERVER: EXISTING
<br />BUILDING STANDARD NOTES
<br />GENERAL:
<br />1. VERIFYING EXISTING CONDITIONS - BEFORE SUBMITTING BID, G.C. SHALL BECOME
<br />THOROUGHLY FAMILIAR WITH ACTUAL EXISTING CONDITIONS AT THE BUILDING. THE
<br />INTENT OF THE WORK IS SHOWN ON THE DRAWINGS AND DESCRIBED HEREINAFTER.
<br />BY THE ACT OF SUBMITTING A BID PROPOSAL FOR WORK, THE CONTRACTOR SHALL
<br />BE DEEMED TO HAVE MADE SUCH A STUDY AND EXAMINATION AND TO ACCEPT ALL
<br />CONDITIONS PRESENT AT THE SITE. NO REQUEST FOR ADDITIONAL PAYMENT SHALL
<br />BE CONSIDERED VALID, DUE TO FAILURE TO ALLOW FOR CONDITIONS WHICH MAY
<br />EXIST.
<br />2. ALL SUBCONTRACTORS SHALL BE CITY AND STATE LICENSED.
<br />3. G.C. TO VERIFY CAPACITY OF EXISTING ELECTRICAL PANEL/TRANSFORMERS IS
<br />ADEQUATE FOR PROPOSED WORK. IF ANY ADDITIONS TO ELECTRICAL CAPACITY OF
<br />BUILDING IS REQUIRED, IT SHALL BE INCLUDED IN SCOPE AND BID FOR PROPOSED
<br />WORK.
<br />4. G.C. TO VERIFY HVAC CONDITIONS/ZONING WITH BUILDING ENGINEER TO ENSURE
<br />ADEQUACY OF EXISTING UNITS FOR SUITE. ANY ADDITIONS TO HVAC EQUIPMENT
<br />SHALL BE INCLUDED IN SCOPE AND BID FOR PROPOSED WORK.
<br />5. ALL SUITES TO RECEIVE TELEPHONE BACKBOARD, U.O.N. TELEPHONE BACKBOARD TO HAVE (1)
<br />SEPARATE CIRCUIT AND (1) 2" CONDUIT TO BASE BUILDING TELEPHONE. SAND AND PAINT
<br />BACKBOARD, U.O.N.
<br />6. ALL EXISTING HANDICAPPED FACILITIES SHALL MEET OR COMPLY WITH TITLE 24
<br />HANDICAPPED ACCESSIBILITY REQUIREMENTS.
<br />7. ALL FIRE LIFE SAFETY, TITLE 24 REQUIREMENT COMPLIANCE MUST BE INCLUDED IN
<br />BID.
<br />8. ELECTRICAL ENGINEER/SUBCONTRACTOR IS RESPONSIBLE FOR FIRE LIFE SAFETY ENGINEERING
<br />AND BUILD -OUT, EXCLUDING SPRINKLERS. SEE FLS SPECS ON SHEET A-2.
<br />9. ALL SPECIFICATIONS FOR EQUIPMENT THAT IS DIFFERENT FROM THE ARCHITECTURAL
<br />DRAWINGS ARE TO BE INDICATED ON THE ENGINEERING DRAWINGS. SEE ENGINEER'S
<br />DRAWINGS FOR COMPLETE SPECIFICATIONS, CONDUIT SIZE AND CONNECTIONS.
<br />10. ALL ARCHITECTURAL AND ENGINEERING DOCUMENTS TO BE PRODUCED ON AUTOCAD
<br />IN .DWG FILE FORMAT. PROPERTY MANAGER/ENGINEERS TO RECEIVE A COPY OF THE
<br />COMPLETED DISCS.
<br />11. SEPARATE MECHANICAL, HVAC, ELECTRICAL, AND FIRE LIFE SAFETY IN THIS SUITE FROM THAT
<br />OF ADJACENT SUITES, AND COMBINE AS REQUIRED WITHIN SUITE, IF NOT ALREADY.
<br />12. PROVIDE PROPER ELECTRICAL AND PLUMBING FOR ALL APPLIANCES AND/OR EQUIPMENT AS
<br />SPECIFIED. SEE PLAN, SPECS, MILLWORK DETAILS, AND KEYNOTES/ALTERNATE PRICING NOTES.
<br />OUTLETS:
<br />13. ALL ELECTRICAL/TELEDATA OUTLETS ARE EXISTING TO REMAIN, U.O.N. BUILDING
<br />STANDARD TELE/DATA COLOR IS WHITE. G.C. TO CONFIRM THAT ALL OUTLETS ARE
<br />OPERATIONAL. ALL OUTLETS THAT ARE DAMAGED, DISCOLORED OR MISSING SCREWS ARE TO BE
<br />REPAIRED OR REPLACED. ALL OUTLETS TO HAVE COVER PLATES. NEW COVER PLATES AND
<br />OUTLET FINISHES TO MATCH EXISTING BUILDING STANDARD, U.O.N.
<br />14. ALL TELEPHONE AND DATA OUTLETS ARE TO BE 3/4" CONDUIT IN A SINGLE RUN
<br />TO BE STUBBED OUT AT 6" ABOVE THE FINISHED CEILING. NO LOOPING. G.C. TO
<br />PROVIDE PULL STRING U.O.N.
<br />15. WHEN A TELE/DATA OR DATA OUTLET IS INDICATED NEXT TO AN ELECTRICAL
<br />OUTLET, THE ENGINEER MUST NOT PROVIDE MORE THAN 4 OUTLETS PER BREAKER.
<br />NO OUTLETS FOR ANY OTHER USE ARE TO BE PROVIDED ON THE SAME BREAKER
<br />WITH DATA ELECTRICAL OUTLETS. TWO (2) SPARE BREAKERS ARE TO REMAIN FOR
<br />THE BUILDING ENGINEER'S USE.
<br />16. ALL OUTLETS NOT STANDARD ARE TO BE LABELED ACCORDINGLY.
<br />17. TYPICAL SPACING FOR WALL OUTLETS IS 6" FROM EACH OTHER. (NO BACK TO BACK
<br />OUTLETS). ALL TELEPHONE AND ELECTRICAL OUTLETS TO BE MOUNTED VERTICALLY @
<br />18" FROM SLAB TO THE CENTER OF OUTLET, U.O.N. ALL OUTLETS NOT DIMENSIONED
<br />ARE TO BE LOCATED TO THE NEAREST STUD.
<br />18. PATCH AND PAINT DRYWALL WHERE EXISTING ELECTRICAL IS TO BE REMOVED.
<br />BLANK PLATES SHALL NOT BE PERMITTED, REMOVE EXISTING BLANK PLATES.
<br />19. ALL OFFICES TO HAVE A MINIMUM OF TWO DUPLEX OUTLETS, ONE TELEPHONE OUTLET, AND
<br />ONE DATA OUTLET. U.O.N. [THE TELEPHONE AND DATA OUTLETS MAY BE COMBINED INTO A
<br />SINGLE MULTI -LINE TELE/DATA OUTLET.]
<br />6ANICE
<br />v v •
<br />Santa Ana, Ca. 92705
<br />TENANT
<br />MWK ,u
<br />AREA SQUARE FOOTAGE
<br />EXISTING SUITE 840: 3,298 SQ.FT.
<br />EXPANDED SUITE 640: 4,486 SQ.FT.
<br />EXISTING SUITE 600: 5,480 SQ.FT.
<br />REDUCED SUITE 600: 4.292 SQ.FT.
<br />THESE DRAWINGS AND/OR THE ACCOMPANING SPECIFICATIONS AS INSTRUMENTS
<br />OF SERVICE, ARE THE EXCLUSIVE PROPERTY OF SPACES AND THEIR USE AND
<br />PUBLICATION SHALL BE RESTRICTED TO THE ORIGINAL SPACE OR SUITE FOR
<br />WHICH THEY WERE PREPARED. RE -USE, REPRODUCTION, OR PUBLICATION BY
<br />ANY MEMOD, IN WHOLE OR IN PART IS PROHIBITED EXCEPT BY WRITTEN PER-
<br />MISSION FROM SPACES. TITLE TO THESE PLANS AND/OR SPECIFICATIONS SHALL
<br />REMAIN SPACES WITHOUT PREJUDICE, AND VISUAL CONTACT WITH THEM SHALL
<br />CONSTITUTE PRIMA FACIA EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS.
<br />PRESCREEN CORRECTIONS 10.08.25
<br />SUBMIT TO 09.15.25
<br />PLAN CHECK
<br />RELEASED TO 09.15.25
<br />NO. DESCRIPTION DATE
<br />REVISIONS
<br />COMMERCIAL INTERIORS
<br />Elmo *A �I
<br />■\■ " M
<br />PLANNING & DESIGN
<br />3150 BRISTOL, STE 205 1 COSTA MESA, CA 92626
<br />949.724.1499 1 www.spaces-oc.com
<br />DRAWN
<br />o ■CALIFORNIA COUNCIL FOR -
<br />6
<br />U
<br />U
<br />0
<br />ip.r-G�,
<br />o DATE
<br />y 09.02.25
<br />G'!
<br />= CHECKED
<br />A RPti
<br />PRINT DATE
<br />= 80J 1ION000 vINNOJI1v0■ =109.10.25
<br />SIXTH
<br />FLOOR
<br />TELEPHONE/
<br />ELECTRICAL
<br />PLAN