2150 & 2160 E Fourth St - Plumbing & Mechanical Revision - Plan
PBA
>
Building
>
ProjectDox
>
F
>
Fourth St
>
2150 E Fourth St
>
2150 & 2160 E Fourth St - Plumbing & Mechanical Revision - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/15/2026 5:00:14 AM
Creation date
1/15/2026 5:00:04 AM
Metadata
Fields
Template:
Plan
Permit Number
30149660
30149661
40141055
40141056
Full Address
2150 E Fourth St
2160 E Fourth St
Street Number
2160
Street Direction
E
Street Name
Fourth
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DIFFUSERS/GRILLES/REGISTERS <br />TAG AIRFLOW <br />RANGE (CFM)NOTES <br />DUCT <br />SIZE <br />(IN.) <br />NOTES: <br />1.ALL PERFORMANCE DATA SHALL BE IN ACCORDANCE WITH ANSI/ASHRAE STANDARDS. <br />2.UNLESS OTHERWISE NOTED, ALL DIFFUSERS/REGISTERS/GRILLES SHALL HAVE NC RATINGS <30. <br />3.COORDINATE FRAME TYPE WITH ARCHITECTURAL RCP. <br />4.COLOR TO BE SPECIFIED BY ARCHITECT. <br />5.PROVIDE GRILLE WITH VERTICAL ORIENTED BLADES AND MULTI SHUTTER DAMPER. <br />MANUFACTURER <br />MODEL NO. <br />FACE <br />SIZE <br />(IN.) <br />PRESS. <br />DROP <br />(IN. W.G.) <br />FUNCTION <br />TAG <br />CFM <br />S-1 TRUAIRE <br />210VM <br />CEILING & WALL <br />SUPPLY GRILLE <br />Ø5 <br />Ø6 <br />Ø7 <br />Ø8 <br />Ø9 <br />Ø10 <br />0 - 50 <br />51 - 100 <br />101 - 150 <br />151 - 200 <br />201 - 300 <br />301 - 400 <br />0.01 <br />0.01 <br />0.01 <br />0.02 <br />0.02 <br />0.01 <br />10 x 4 <br />10 x 6 <br />12 x 6 <br />14 X 6 <br />14 X 8 <br />14 X 12 <br /> 1,2,3,4,5 <br />R-1 TRUAIRE <br />290 FIXED BAR <br />CEILING & WALL <br />RETURN GRILLE <br />Ø10 <br />Ø18 <br />0 - 850 <br />0 - 2500 0.06514 X 14 <br />30 X 20 1,2,3,4,5 <br />GENERAL <br />SCHEDULE OF FANS <br />TYPE <br />TAG SERVICE MANUFACTURER <br />MODEL NO. <br />NOTES <br />LOCATION <br />NOTES: <br />1.ALL FANS SHALL BE TESTED AND RATED, CERTIFIED, AND SEALED IN ACCORDANCE WITH AMCA FOR BOTH SOUND AND AIR PERFORMANCE. <br />ALL FANS SHALL BE U.L. LISTED. <br />2.FAN SHALL BE PROVIDED WITH A NEMA-1 (INDOORS) OR NEMA-3R (OUTDOORS) DISCONNECT SWITCH. REFER TO ELECTRICAL DRAWINGS FOR <br />MORE INFORMATION. <br />3.PROVIDE GRAVITY BACKDRAFT DAMPER IN THROAT OF EXHAUST DUCT. <br />4.FAN SHALL BE PROVIDED WITH BUILT-IN HUMIDITY SENSOR. <br />FAN DATA MOTOR <br />WEIGHT <br />(LBS) <br />TYPE / <br />DESIGN <br />TAG <br />TYPE <br />SONES <br />EXTERNAL <br />STATIC <br />PRESSURE <br />(IN. W.G.) <br />TOTAL <br />AIR QTY <br />(CFM) <br />MOTOR <br />TYPE <br />RATED <br />SIZE <br />VOLTS/ <br />PHASE/ <br />HERTZ <br />EF <br />B BATHROOM AIRKING <br />ES80SH CEILING 17.0 CEILING <br />MOUNTED 80 0.1 0.3 29.4 W 120/1/60 1,2,3PSC <br />NOTE: ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL RELAYS AS REQUIRED TO <br />ACHIEVE CONTROL OF UNITS AS SPECIFIED BELOW <br />SEQUENCE OF OPERATIONS <br />Unit shall operate via a wall-mounted thermostat. Fan to operate as required by <br />thermostat. Cooling and heating modes shall operate as required by thermostat.FC/CU's <br />Fan to operate continuously while house is occupied. Fan to act as IAQ fan to meet <br />ASHRAE 62.2 ventilation requirements.EF B <br />AIR SYSTEM DESIGN <br />CRITERIA <br />CITY SANTA ANA <br />COUNTY ORANGE <br />CLIMATE ZONE 08 <br />SUMMER AMBIENT DESIGN <br />TEMPERATURE (°F DB/WB)91 / 68 <br />SUMMER DAILY RANGE (°F WB)26 <br />WINTER AMBIENT DESIGN <br />TEMPERATURE (°F DB)33 <br />SUMMER INDOOR DESIGN <br />TEMPERATURE (°F DB)75 <br />WINTER INDOOR DESIGN <br />TEMPERATURE (°F DB)68 <br />WHOLE UNIT VENTILATION <br />CALCULATION (ASHRAE 62.2) <br />CONTINUOUSLY <br />LOCATION UNIT A-1 <br />FLOOR AREA (SQFT)830 <br />NO. OF BEDROOMS 2 <br />VENTILATION RATE (CFM) = 0.03(SQFT) <br />+7.5(BEDROOMS+1)47.4 <br />DESIGNED VENTILATION (CFM)80 <br />18 <br />GENERAL <br />SCHEDULE OF NEW HEAT PUMP CONDENSING UNITS <br />TAG SERVICE MANUFACTURER <br />MODEL NO.TONSLOCATION <br />AMB. <br />DB <br />(°F) <br />TOTAL <br />LOAD <br />(MBH) <br />SENS. <br />LOAD <br />(MBH) <br />COOLING HEATING <br />WEIGHT <br />(LBS) <br />TOTAL <br />LOAD <br />(MBH) <br />REF. PIPING <br />TYPE <br />VOLTS/ <br />PHASE/ <br />HERTZ <br />MCA <br />(A) <br />MOCP <br />(A) <br />ELECTRICAL <br />TAG <br />HP <br />NOTESAMB. <br />DB <br />(°F) <br />EER <br />(EER2) <br />SEER / <br />(SEER2) <br />HSPF/ <br />(HSPF2) <br /> CONN. Ø <br />LIQUID / <br />SUCTION <br />(IN.) <br />SYSTEM <br />CHARGE <br />(LBS) <br />NOTES: <br />1.DISCONNECT SWITCH TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. <br />2.PROVIDE CONTROL WIRING, CONDUIT, ETC. FOR A COMPLETE AND OPERABLE SYSTEM. <br />3.PROVIDE ALL REQUIRED MATERIALS & INSULATED REFRIGERANT LINES FOR COMPLETE INSTALLATION. SIZE RS/RL PIPING PER MANUFACTURERS GUIDELINES. <br />4.RS/RL ACCESS PORTS LOCATED OUTDOORS SHALL BE PROTECTED FROM UNAUTHORIZED ACCESS WITH LOCKING TYPE TAMPER RESISTANT CAPS. UNLESS THEY ARE PROTECTED BY WALLS OR <br />FENCING AND REQUIRING KEY ACCESS. <br />5.CONDENSING UNIT SHALL REST ON A CONCRETE OR OTHER APPROVED BASE PER DETAILS ON MD-1. <br />6.INSTALL EQUIPMENT IN ACCORDANCE WITH BOTH THE DETAILS SHOWN IN THE CONTRACT DOCUMENTS AND IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. <br />NOTES: <br />1.DISCONNECT SWITCH TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. <br />2.PROVIDE HARD-WIRED PROGRAMMABLE SETBACK THERMOSTAT, CONTROL WIRING, CONDUIT, ETC. FOR A COMPLETE AND OPERABLE SYSTEM. <br />3.PROVIDE UNIT WITH ECM MOTOR SET TO PROVIDE CFM QUANTITIES PER SCHEDULE. <br />4.PROVIDE UNIT WITH ACCESS PER MANUFACTURER'S RECOMMENDATIONS AND LOCAL CODE REQUIREMENTS. <br />5.PROVIDE UNIT WITH FACTORY SECONDARY DRAIN PAN. <br />6.PROVIDE ALL REQUIRED MATERIALS & INSULATED REFRIGERANT LINES FOR COMPLETE INSTALLATION. SIZE RS/RL PIPING PER MANUFACTURERS GUIDELINES. <br />7.INDOOR UNIT TO RECEIVE POWER FROM OUTDOOR UNIT. <br />8.PROVIDE MERV 13 FILTER. <br />GENERAL <br />SCHEDULE OF NEW FAN COIL UNITS <br />TAG SERVICE MANUFACTURER <br />MODEL NO.HPLOCATION WEIGHT <br />(LBS) <br />VOLTS/ <br />PHASE/ <br />HERTZ <br />MCA <br />(A) <br />MOCP <br />(A) <br />ELECTRICAL <br />TAG <br />FC <br />NOTESOUTSIDE <br />AIR QTY <br />(CFM) <br />EXTERNAL <br />STATIC <br />PRESSURE <br />(IN. W.G.) <br />TOTAL <br />AIR QTY <br />(CFM) <br />FAN DATA <br />TOTAL <br />LOAD <br />(MBH) <br />SENS. <br />LOAD <br />(MBH) <br />COOLING HEATING <br />TOTAL <br />LOAD <br />(MBH) <br />ELEC. <br />HEAT <br />18 CARRIER <br />40MBDQ18---3 18 54 16.5 18.0 N/A 1,2,6,7,80600SEE PLAN --SEE PLAN 208/230/1 <br />/60 <br />POWERED <br />BY <br />OUTDOOR <br />UNIT <br />1.20.4 <br />1.5 208/230/1 <br />/60 251616.5 --1/4 <br />1/2 1,2,3,4,5,612.5 <br />(11.7) <br />19.6 <br />(18.0)19.0 4.08R-410A11.0 <br />(9.5)95 47CARRIER <br />38MARBQ18--3 101SEE PLAN GROUND <br />EF <br />L LAUNDRY AIRKING <br />E130S CEILING 14.1 CEILING <br />MOUNTED 130 0.1 <0.3 37.0 120/1/60 1,2,3PSC <br />SF <br />C CORRIDOR BROAN <br />FIN-180P CEILING 11.0 CEILING <br />MOUNTED 180 0.2 -28.2 120/1/60 1,2,3ECM <br />al <br />l <br /> <br />i <br />d <br />e <br />a <br />s <br />, <br /> <br />d <br />e <br />s <br />i <br />g <br />n <br />s <br /> <br />a <br />n <br />d <br /> <br />p <br />l <br />a <br />n <br />s <br /> <br />r <br />e <br />p <br />r <br />e <br />s <br />e <br />n <br />t <br />e <br />d <br /> <br />b <br />y <br /> <br />t <br />h <br />i <br />s <br /> <br />d <br />r <br />a <br />w <br />i <br />n <br />g <br /> <br />a <br />r <br />e <br /> <br />t <br />h <br />e <br /> <br />e <br />x <br />c <br />l <br />u <br />s <br />i <br />v <br />e <br /> <br />p <br />r <br />o <br />p <br />e <br />r <br />t <br />y <br /> <br />o <br />f <br />Go <br />u <br />v <br />i <br />s <br /> <br />E <br />n <br />g <br />i <br />n <br />e <br />e <br />r <br />i <br />n <br />g <br /> <br />a <br />n <br />d <br /> <br />s <br />h <br />a <br />l <br />l <br /> <br />n <br />o <br />t <br /> <br />b <br />e <br /> <br />r <br />e <br />p <br />r <br />o <br />d <br />u <br />c <br />e <br />d <br /> <br />i <br />n <br /> <br />w <br />h <br />o <br />l <br />e <br /> <br />o <br />r <br /> <br />i <br />n <br /> <br />p <br />a <br />r <br />t <br /> <br />w <br />i <br />t <br />h <br />o <br />u <br />t <br /> <br />t <br />h <br />e <br /> <br />e <br />x <br />p <br />r <br />e <br />s <br />s <br /> <br />p <br />r <br />i <br />o <br />r <br /> <br />w <br />r <br />i <br />t <br />t <br />e <br />n <br /> <br />p <br />e <br />r <br />m <br />i <br />s <br />s <br />i <br />o <br />n <br /> <br />o <br />f <br /> <br />s <br />a <br />i <br />d <br /> <br />e <br />n <br />g <br />i <br />n <br />e <br />e <br />r <br />s <br />, <br /> <br />a <br />n <br />y <br /> <br />u <br />n <br />a <br />u <br />t <br />h <br />o <br />r <br />i <br />z <br />e <br />d <br /> <br />r <br />e <br />u <br />s <br />e <br /> <br />o <br />f <br /> <br />t <br />h <br />e <br />s <br />e <br /> <br />p <br />l <br />a <br />n <br />s <br /> <br />o <br />t <br />h <br />e <br />r <br /> <br />t <br />h <br />a <br />n <br /> <br />f <br />o <br />r <br /> <br />t <br />h <br />e <br /> <br />p <br />r <br />o <br />j <br />e <br />c <br />t <br /> <br />a <br />n <br />d <br /> <br />l <br />o <br />c <br />a <br />t <br />i <br />o <br />n <br /> <br />s <br />h <br />o <br />w <br />n <br /> <br />i <br />s <br /> <br />p <br />r <br />o <br />h <br />i <br />b <br />i <br />t <br />e <br />d <br />. <br />JOB NO. <br />SUBMITTAL <br />SHEET TITLE <br />SHEET NO. <br />CLIENT: <br />DATE <br />21 <br />3 <br />0 <br /> <br />E <br /> <br />4 <br />T <br />H <br /> <br />S <br />T <br /> <br /># <br />2 <br />0 <br />0 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />BSB: MR230056; Gouvis: 66467 <br />WATER REVISIONS <br />09/12/2025 <br />1ST PLAN CHECK SUBMITTAL 08/20/2024 <br />2ND PLAN CHECK SUBMITTAL 1/29/2025 <br />3RD PLAN CHECK SUBMITTAL 04/17/2025 <br />4TH PLAN CHECK SUBMITTAL 07/10/2025 <br />WATER REVISIONS 09/12/2025 <br />OL <br />I <br />V <br />E <br /> <br />C <br />R <br />E <br />S <br />T <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />T <br />I <br />A <br />L <br />21 <br />5 <br />0 <br /> <br />E <br />. <br /> <br />F <br />O <br />U <br />R <br />T <br />H <br /> <br />A <br />N <br />D <br /> <br />2 <br />1 <br />6 <br />0 <br /> <br />E <br />. <br /> <br />F <br />O <br />U <br />R <br />T <br />H <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />OL <br />I <br />V <br />E <br /> <br />C <br />R <br />E <br />S <br />T <br />DATE SIGNED: 7/8/25 <br />M-0.2 <br />EQUIPMENT <br />SCHEDULES <br />PC COMMENTS RESPONSE #1 01/29/2025A <br />DATEREVISION <br />PC COMMENTS RESPONSE #2 04/17/2025B <br />PC COMMENTS RESPONSE #3 07/10/2025C <br />WATER REVISIONS 09/12/2025D <br />PC COMMENTS RESPONSE #4 10/10/2025E <br />CLIENT REVISIONS 10/10/20251