Laserfiche WebLink
PC COMMENTS RESPONSE #1 01/29/2025A <br />al <br />l <br /> <br />i <br />d <br />e <br />a <br />s <br />, <br /> <br />d <br />e <br />s <br />i <br />g <br />n <br />s <br /> <br />a <br />n <br />d <br /> <br />p <br />l <br />a <br />n <br />s <br /> <br />r <br />e <br />p <br />r <br />e <br />s <br />e <br />n <br />t <br />e <br />d <br /> <br />b <br />y <br /> <br />t <br />h <br />i <br />s <br /> <br />d <br />r <br />a <br />w <br />i <br />n <br />g <br /> <br />a <br />r <br />e <br /> <br />t <br />h <br />e <br /> <br />e <br />x <br />c <br />l <br />u <br />s <br />i <br />v <br />e <br /> <br />p <br />r <br />o <br />p <br />e <br />r <br />t <br />y <br /> <br />o <br />f <br />Go <br />u <br />v <br />i <br />s <br /> <br />E <br />n <br />g <br />i <br />n <br />e <br />e <br />r <br />i <br />n <br />g <br /> <br />a <br />n <br />d <br /> <br />s <br />h <br />a <br />l <br />l <br /> <br />n <br />o <br />t <br /> <br />b <br />e <br /> <br />r <br />e <br />p <br />r <br />o <br />d <br />u <br />c <br />e <br />d <br /> <br />i <br />n <br /> <br />w <br />h <br />o <br />l <br />e <br /> <br />o <br />r <br /> <br />i <br />n <br /> <br />p <br />a <br />r <br />t <br /> <br />w <br />i <br />t <br />h <br />o <br />u <br />t <br /> <br />t <br />h <br />e <br /> <br />e <br />x <br />p <br />r <br />e <br />s <br />s <br /> <br />p <br />r <br />i <br />o <br />r <br /> <br />w <br />r <br />i <br />t <br />t <br />e <br />n <br /> <br />p <br />e <br />r <br />m <br />i <br />s <br />s <br />i <br />o <br />n <br /> <br />o <br />f <br /> <br />s <br />a <br />i <br />d <br /> <br />e <br />n <br />g <br />i <br />n <br />e <br />e <br />r <br />s <br />, <br /> <br />a <br />n <br />y <br /> <br />u <br />n <br />a <br />u <br />t <br />h <br />o <br />r <br />i <br />z <br />e <br />d <br /> <br />r <br />e <br />u <br />s <br />e <br /> <br />o <br />f <br /> <br />t <br />h <br />e <br />s <br />e <br /> <br />p <br />l <br />a <br />n <br />s <br /> <br />o <br />t <br />h <br />e <br />r <br /> <br />t <br />h <br />a <br />n <br /> <br />f <br />o <br />r <br /> <br />t <br />h <br />e <br /> <br />p <br />r <br />o <br />j <br />e <br />c <br />t <br /> <br />a <br />n <br />d <br /> <br />l <br />o <br />c <br />a <br />t <br />i <br />o <br />n <br /> <br />s <br />h <br />o <br />w <br />n <br /> <br />i <br />s <br /> <br />p <br />r <br />o <br />h <br />i <br />b <br />i <br />t <br />e <br />d <br />. <br />JOB NO. <br />SUBMITTAL <br />DATE <br />SHEET TITLE <br />SHEET NO. <br />CLIENT: <br />REVISION <br />DATE <br />21 <br />3 <br />0 <br /> <br />E <br /> <br />4 <br />T <br />H <br /> <br />S <br />T <br /> <br /># <br />2 <br />0 <br />0 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />BSB: MR230056; Gouvis: 66467 <br />WATER REVISIONS <br />09/12/2025 <br />1ST PLAN CHECK SUBMITTAL 08/20/2024 <br />2ND PLAN CHECK SUBMITTAL 1/29/2025 <br />PC COMMENTS RESPONSE #2 04/17/2025B <br />3RD PLAN CHECK SUBMITTAL 04/17/2025 <br />PC COMMENTS RESPONSE #3 07/10/2025C <br />4TH PLAN CHECK SUBMITTAL 07/10/2025 <br />WATER REVISIONS 09/12/2025D <br />WATER REVISIONS 09/12/2025 <br />PC COMMENTS RESPONSE #4 10/10/2025E <br />CLIENT REVISIONS 10/10/20251 <br />OL <br />I <br />V <br />E <br /> <br />C <br />R <br />E <br />S <br />T <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />T <br />I <br />A <br />L <br />21 <br />5 <br />0 <br /> <br />E <br />. <br /> <br />F <br />O <br />U <br />R <br />T <br />H <br /> <br />A <br />N <br />D <br /> <br />2 <br />1 <br />6 <br />0 <br /> <br />E <br />. <br /> <br />F <br />O <br />U <br />R <br />T <br />H <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />OL <br />I <br />V <br />E <br /> <br />C <br />R <br />E <br />S <br />T <br />DATE SIGNED: 7/8/25 <br />PART 1: GENERAL <br />A.PROVIDE ALL WORK AND MATERIALS FOR THE INSTALLATION OF COMPLETE WIRING SYSTEMS <br />AS SPECIFIED HEREIN AND INDICATED ON THE DRAWINGS. <br />B.ALL ELECTRICAL PERMITS AND INSPECTION FEES SHALL BE OBTAINED AND PAID FOR BY THE <br />ELECTRICAL CONTRACTOR. <br />C.ELECTRICAL CONTRACTOR SHALL GUARANTEE ALL WORK AND MATERIALS FOR ONE YEAR <br />EFFECTIVE THE DAY THE PROJECT IS ACCEPTED BY THE OWNER. <br />D.WORK SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE, OSHA, STATE <br />BUILDING CODE AND ALL OTHER APPLICABLE LOCAL REQUIREMENTS. ALL WORK SHALL <br />COMPLY WITH THE LATEST ADDITION OF NECA STANDARDS OF INSTALLATION. <br />E.ALL MATERIALS, DEVICES, AND APPLIANCES SHALL BE NEW, EXCEPT WHERE OTHERWISE <br />NOTED, AND SHALL BE LISTED BY AN APPROVED TESTING AGENCY WHERE SUCH A LISTING IS <br />AVAILABLE. FACTORY ASSEMBLED EQUIPMENT SHALL BE LISTED AND LABELED AS AN <br />ASSEMBLY, ANY EQUIPMENT NOT LISTED SHALL HAVE PRIOR APPROVAL FROM THE LOCAL <br />AUTHORITY HAVING JURISDICTION. ALL MATERIALS SHALL COMPLY WITH APPLICABLE ANSI, <br />IEEE AND NEMA STANDARDS. <br />F.PROVIDE ALL CUTTING, PATCHING, CHANNELING AND CHASING FOR INSTALLATION OF WORK <br />AND REPAIR ANY DAMAGE OF EXISTING OR NEW INSTALLATIONS AT THE CONTRACTORS <br />EXPENSE. <br />G.SHOP DRAWINGS AND CATALOG DATA SHALL BE SUBMITTED FOR APPROVAL PRIOR TO <br />BEGINNING WORK. SUBMIT FOUR COPIES OF SHOP DRAWINGS FOR LIGHTING FIXTURES, <br />LAMPS, BALLASTS AND PANELBOARDS. SUBMIT FOUR COPIED OF CATALOG DATA FOR <br />DISCONNECT SWITCHES AND WIRING DEVICES. <br />H.PROVIDE ENGRAVED PHENOLIC NAMEPLATES FOR PANELBOARDS, WIRING TROUGHS, AND <br />FUSED SWITCHES, WHITE LETTERS ON BLACK FOR 120/208 VOLT SYSTEMS. LABEL ALL <br />BREAKERS INSIDE THE PANEL NEXT TO THE BREAKER USING THE NUMBER SCHEME <br />INDICATED ON THE DRAWINGS. <br />I.AN ELECTRICAL INSPECTION CERTIFICATE SHALL BE ISSUED BY THE LOCAL INSPECTION <br />AUTHORITIES BEFORE APPROVAL FOR FINAL PAYMENT. <br />J.THE CONDUIT AND NEUTRAL SYSTEM SHALL BE GROUNDED AT THE MAIN SERVICE <br />EQUIPMENT. GROUNDING ELECTRODE SYSTEM SHALL BE INSTALLED PER N.E.C. ARTICLE 250 <br />AND AS INDICATED ON THE DRAWINGS. <br />K.WIRING SHALL BE TESTED FOR CONTINUITY AND GROUNDS BEFORE BEING ENERGIZED. <br />FAULTY WIRING SHALL BE REPLACED AT NO ADDITIONAL EXPENSE TO THE OWNER. <br />L.IF, DURING THE COURSE OF WORK, THE ELECTRICAL CONTRACTOR DISCOVERS A PROBLEM <br />WITH THE PERFORMANCE OF THE INSTALLATION RELATIVE TO THE PLANS AND <br />SPECIFICATIONS OR NEC OR OTHER CODES, THE CONTRACTOR SHALL IMMEDIATELY BRING <br />THE PROBLEM TO THE ATTENTION OF THE ARCHITECT OR ENGINEER FOR RESOLUTION PRIOR <br />TO THE EXECUTION OF THE WORK. <br />M.THE ELECTRICAL CONTRACTOR SHALL CONNECT ALL EQUIPMENT REQUIRING ELECTRICAL <br />CONNECTIONS, UNLESS OTHERWISE NOTED, EXCEPT FOR CONTROL WIRING FOR EQUIPMENT <br />NOT PROVIDED BY THE ELECTRICAL CONTRACTOR. CONTROL WIRING FOR SUCH EQUIPMENT <br />SHALL BE PROVIDED BY THE RESPECTIVE DISCIPLINE. <br />N.COORDINATE LOCATION AND REQUIREMENTS FOR ELECTRICAL SERVICE WITH THE POWER <br />COMPANY. WHERE MORE THAN ONE SERVICE IS SUPPLIED TO A BUILDING, PROVIDE <br />IDENTIFICATION AT EACH SERVICE PER NEC 230-2(B) AND AS INDICATED ON THE DRAWINGS. <br />O.COORDINATE LOCATION AND REQUIREMENTS FOR TELEPHONE SERVICE WITH THE <br />TELEPHONE COMPANY AND AS INDICATED ON THE DRAWINGS. <br />P.THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING AND PROVIDING <br />TEMPORARY POWER. <br />PART 2: RACEWAY <br />A.CONDUIT SHALL BE ZINC-COATED EMT INDOORS. EMT FITTINGS SHALL BE STEEL SCREW. <br />MINIMUM SIZE SHALL BE ½"C, UNLESS OTHERWISE NOTED. USE SCHEDULE 40 PVC <br />OUTDOORS ABOVE 8'-0" OR BELOW GRADE. USE IMC WHERE REQUIRED BY CODE OR <br />EXPOSED BELOW 8'-0". <br />B.SUPPORT ALL CONDUITS WITH STRAPS AND CLAMPS. RUN ALL CONDUIT PARALLEL OR <br />PERPENDICULAR TO BUILDING WALLS. <br />C.JUNCTION AND PULL BOXES SHALL BE CODE GAUGE GALVANIZED SHEET METAL. <br />D.LIQUID-TIGHT FLEXIBLE METAL CONDUIT SHALL BE USED FOR EQUIPMENT CONNECTIONS, BUT <br />NOT AS A WIRING METHOD OTHERWISE. <br />E.MC CABLE MAY BE USED AS A WIRING METHOD WHERE ALLOWED BY CODE. <br />F.RACEWAY PENETRATIONS THROUGH FLOOR SLABS AND FIRE-RATED WALLS SHALL BE FILLED <br />WITH IMPERVIOUS, NON-SHRINK GROUT SUFFICIENTLY TIGHT TO PREVENT THE TRANSFER OF <br />SMOKE, WATER, AND DUST. ROOF PENETRATIONS SHALL BE WITHIN THE EQUIPMENT CURB <br />WHERE POSSIBLE. <br />G.CONDUIT INSTALLED UNDERGROUND OR IN CONCRETE SHALL HAVE JOINTS MADE <br />WATER-TIGHT BY USE OF POLYTETRA-FLUOROETHYLENE TAPE. AAPPROVED SEALS SHALL BE <br />PROVIDED IN HAZARDOUS LOCATIONS AS REQUIRED BY THE N.E.C. <br />PART 3: CONDUCTORS <br />A. ALL CONDUCTORS SHALL BE SINGLE CONDUCTOR COPPER. THHN/THWN, SOLID FOR SIZES <br />#14 THROUGH #10. THHN/THWN STRANDED FOR SIZES #8 AND LARGER. <br />B.BRANCH CIRCUITS SHALL NOT BE SMALLER THAN #12 AWG. CONTROL WIRING MAY BE #14 <br />AWG. <br />C.CONDUCTORS SHALL BE COLOR CODED BLACK/RED/BLUE FOR 120/208 VOLT SYSTEMS FOR A, <br />B, AND C PHASES, RESPECTIVELY. <br />D.WIRING TO LIGHTING FIXTURES SHALL BE AS REQUIRED BY UL LABEL. <br />E.ALL BRANCH CIRCUIT CONDUITS OR CABLE ASSEMBLIES SHALL CONTAIN AN INSULATED <br />GREEN GROUNDING CONDUCTOR SIZED PER NEC 250-122. <br />F.ALL CONDUCTORS INSTALLED IN VERTICAL RACEWAYS SHALL BE SUPPORTED AT INTERVALS <br />AS REQUIRED PER NEC ARTICLE 300-19. <br />G.ALL EQUIPMENT AND DEVICE TERMINATIONS SHALL BE UL LISTED FOR USE WITH 75°C <br />INSULATED CONDUCTORS AT THEIR 75°C AMPACITY. <br />H.PROVIDE A SEPARATE NEUTRAL FOR EACH PHASE CONDUCTOR IN ALL BRANCH CIRCUITS. <br />PART 4: WIRING DEVICES <br />A.WIRING DEVICES SHALL BE ALMOND WITH MATCHING PLASTIC COVER PLATES, <br />SPECIFICATION GRADE AS INDICATED BELOW, EQUAL TO THE COOPER QUALITY INDICATED. <br />VERIFY WITH ARCHITECT & BRAND STANDARDS PRIOR TO ORDERING. <br />TOGGLE SWITCHES SHALL BE AS FOLLOWS: <br />SINGLE POLE 20 AMP COOPER 1221 <br />THREE WAY 20 AMP COOPER 1223 <br />SINGLE POLE/KEY 20 AMP COOPER 1221L <br />THREE WAY/KEY 20 AMP COOPER 1223L <br />DUPLEX RECEPTACLES SHALL HAVE A NYLON FACE AND SHALL BE AS FOLLOWS: <br />15 AMP DUPLEX COOPER 5252 <br />20 AMP DUPLEX COOPER 5362 <br />15 AMP DUPLEX-GFCI COOPER GF5262 <br />20 AMP DUPLEX-GFCI COOPER GF5362 <br />20 AMP DUPLEX/USB/TAMPER COOPER TR7745 <br />15 AMP DUPLEX-IG COOPER IG5252 <br />20 AMP DUPLEX-IG COOPER IG5362 <br />15 AMP DUPLEX-IG/TVSS COOPER IG5252S <br />20 AMP DUPLEX-IG/TVSS COOPER IG5362S <br />B.DUPLEX RECEPTACLES ON DEDICATED CIRCUIT SHALL BE 20 AMP. OTHER DUPLEX <br />RECEPTACLES MAY BE 15 AMP, UNLESS OTHERWISE NOTED. <br />C. OUTLET BOXES SHALL NOT BE MOUNTED BACK-TO-BACK. <br />D. A MAXIMUM OF 10 RECEPTACLES SHALL BE ON EACH BRANCH CIRCUIT. <br />E. WEATHERPROOF COVERS SHALL HAVE A LID SO THAT PLUGS MAY BE INSTALLED WITHOUT <br />COMPROMISING THE WP FUNCTION, EQUAL TO INTERMATIC GUARDIAN ONE #WP102OC. <br />F.ALL OUTLETS (INCLUDING TELEPHONE, CABLE TV AND DATA) SHALL HAVE COVER PLATES, <br />BLANK IF NOT USED. <br />PART 5: DISCONNECT SWITCHES <br />A.DISCONNECT SWITCHES SHALL BE HEAVY-DUTY TYPE IN NEMA 1 ENCLOSURES (UNLESS <br />OTHERWISE INDICATED), FUSED OR NON-FUSED AS INDICATED. FUSED SWITCHES SHALL <br />HAVE REJECTION-TYPE FUSE CLIPS. SWITCHES SHALL BE SQUARE D, OR EQUAL. FUSES <br />SHALL BE CLASS R-5, TIME DELAY. A SET OF 3 SPARE FUSES OF EACH SIZE AND TYPE SHALL <br />BE FURNISHED TO THE OWNER. <br />PART 6: PANELBOARDS <br />A.PANELBOARDS SHALL BE DEAD-FRONT SAFETY TYPE. ALL CIRCUIT BREAKERS SHALL BE <br />MOLDED-CASE, AUTOMATIC THERMAL MAGNETIC TYPE, CALIBRATED FOR 40°C, OR <br />AMBIENT COMPENSATION. CABINET SHALL BE 20 INCHES WIDE MINIMUM, WITH NOT LESS <br />THAT 4-INCH WIRING GUTTERS AT TOP, SIDES, AND BOTTOM, SQUARE D "NF", "NQOD", OR <br />EQUAL. BUS SHALL BE ALUMINUM WITH RATINGS AS INDICATED ON DRAWINGS. LUGS SHALL <br />BE SIZED TO ACCOMMODATE CONDUCTORS INDICATED ON THE POWER RISER DIAGRAM. <br />B.PROVIDE HANDLE LOCK-ON DEVICES ON ALL CIRCUIT BREAKERS CONNECTED TO <br />EMERGENCY, EXIT, AND NIGHT LIGHTING, FIRE ALARM, TELEPHONE AND SECURITY SYSTEMS. <br />C.CIRCUIT BREAKERS USED FOR SWITCHING OF LIGHTING OR SIGN CIRCUITS SHALL BE <br />SWITCHING DUTY RATED AND SHALL BE MARKED "SWD". <br />PART 7: LIGHT FIXTURES <br />A.CATALOG NUMBERS GIVEN DENOTE MINIMUM QUALITY AND PERFORMANCE REQUIRED. <br />EQUAL EQUIPMENT BY OTHER MANUFACTURERS IS ACCEPTABLE AS INDICATED ON THE LIGHT <br />FIXTURE SCHEDULE. <br />B. H.I.D. BALLASTS SHALL BE HIGH POWER FACTOR WITH QUIETEST SOUND RATING. <br />C. LAY-IN FIXTURES SHALL BE SUSPENDED FROM STRUCTURE WITH 2 WIRES AT OPPOSITE <br />CORNERS. DO NOT SUPPORT FROM CEILING GRID. <br />D. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF LIGHT FIXTURES. <br />E. ALL RECESSED LIGHTING FIXTURES SHALL BE THERMALLY PROTECTED. <br />F.COMPACT FLUORESCENT BALLASTS SHALL BE ELECTRONIC WITH END OF LIFE PROTECTION. <br />G.LED FIXTURE SHALL HAVE 0-10V DIMMING DRIVERS AS SPECIFIED IN LIGHT FIXTURE <br />SCHEDULE. <br />H.LED FIXTURES SHALL BE SPECIFICATION GRADE AND DRIVERS SHALL HAVE INRUSH <br />PROTECTION <br />PART 8: TELEPHONE/DATA SYSTEM <br />A.FURNISH AND INSTALL A COMPLETE TELEPHONE/DATA CONDUIT SYSTEM AS INDICATED ON <br />THE DRAWINGS. ALL OUTLET BOXES FOR TELEPHONE AND/OR DATA JACKS SHALL BE DOUBLE <br />GANG WITH A SINGLE-GANG OPENING. <br />B.PULL AND LEAVE IN EACH CONDUIT ONE PULL CORD FOR PULLING IN CABLE. ALL WIRING, <br />OUTLETS AND EQUIPMENT SHALL BE PROVIDED AND INSTALLED BY THE OWNERS TELE/DATA <br />SUPPLIER. <br />C.TELEPHONE SERVICE CONDUITS SHALL BE PROVIDED TO THE PROPERTY LINE OR AS <br />INDICATED ON THE DRAWINGS. <br />D.THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL A #6 AWG GREEN COPPER WIRE <br />IN A 3/4" CONDUIT FROM THE NEAREST COLD WATER METAL MAIN TO A LUG AT THE <br />TELEPHONE/DATA BACKBOARD. <br />PART 9: LIGHTING CONTROLS <br />A.FURNISH AND INSTALL AN ELECTRONIC TIME CONTROLLER WHERE INDICATED. CONTROLLER <br />SHALL BE CAPABLE OF SWITCHING 40 AMPERES PER POLE CONTINUOUSLY AT 120 VOLTS AND <br />SHALL BE SPST (DPST, 3PST, DPTDT, SPDT, AS REQUIRED). <br />B. LIGHTING CONTACTORS SHALL SWITCH A LOAD AT 120 VOLTS, 60 HZ AND SHALL HAVE THE <br />NUMBER OF POLES INDICATED ON THE DRAWINGS. THE CONTACTOR SHALL BE <br />CONTINUOUSLY RATED 20 AMPERES PER POLE FOR ALL TYPES OF BALLAST AND TUNGSTEN <br />LIGHTING AND RESISTANCE LOADS. <br />C. ALL LIGHTING CONTACTORS SHALL BE ELECTRICALLY HELD AND HAVE A NEMA 1 ENCLOSURE <br />UNLESS OTHERWISE NOTED. <br />ELECTRICAL SPECIFICATIONS NOTE <br />PART 10: FIRE STOPPING <br />A.ALL PENETRATIONS OF NON-RATED PENETRATIONS SHALL BE SEALED WITH RATED <br />MATERIALS MEETING ASTM E-814. <br />B.PROVIDE FIRE STOPPING DEVICE(S) OR SYSTEM(S) WHICH HAVE BEEN TESTED AND LISTED AS <br />COMPLYING WITH ASTM E-814. INSTALL THE DEVICE(S) OR SYSTEM(S) IN ACCORDANCE WITH <br />THE CONDITIONS OF THEIR LISTING. PROVIDE THE APPROPRIATE DEVICE(S) OR SYSTEM(S) <br />WITH AN "F" RATING EQUAL TO THE RATING OF THE ASSEMBLY BEING PENETRATED. <br />C.DEVICE(S) AND/OR SYSTEM(S) SHALL BE BY HILTI, 3M OR EQUIVALENT. <br />D.WHERE OPENINGS FOR INSTALLATION OF ELECTRICAL BOXES EXCEEDS 16 SQUARE INCHES IN <br />RATED WALLS OR PARTITIONS, THE OPENING SHALL BE PROTECTED AS REQUIRED BY THE <br />APPROPRIATE WALL LISTING TYPE. <br />PART 11: RENOVATION OF EXISTING <br />A.EACH BIDDER SHALL VISIT THE PROJECT SITE PRIOR TO BID AND FAMILIARIZE HIMSELF WITH <br />THE EXISTING CONDITIONS. FAILURE TO VISIT THE SITE SHALL NOT EXCUSE THE <br />CONTRACTOR FROM PERFORMING THE REQUIRED WORK NOR SHALL IT BE AN ACCEPTABLE <br />REASON FOR REQUESTING ADDITIONS TO THE CONTRACT. <br />B.EXISTING PORTIONS OF THE FACILITY SHALL REMAIN IN OPERATION DURING THIS <br />RENOVATION AND/OR ADDITION. THE CONTRACTOR SHALL CAUSE AS LITTLE DISRUPTION AS <br />POSSIBLE TO MAINTAIN THE COMFORT AND SAFETY OF THE BUILDING OCCUPANTS. ALL <br />POWER OUTAGES SHALL BE CLOSELY COORDINATED WITH THE OWNER'S REPRESENTATIVE. <br />C.PROJECT INVOLVES WORK ON EXISTING ELECTRICAL PANELS AND FEEDERS REQUIRED IN <br />OPERATING THE FACILITY. TEMPORARY POWER ARRANGEMENTS SHALL BE MADE TO SERVE <br />THOSE AREAS AFFECTED BY THIS PROJECT. <br />SEISMIC RESTRAINT OF ELECTRICAL SYSTEMS - DESIGN/BUILD SPECIFICATION <br />THE ELECTRICAL CONTRACTOR SHALL RETAIN THE SERVICES OF A STRUCTURAL ENGINEER <br />TO DETERMINE SITE CLASSIFICATION AND SEISMIC RESTRAINT REQUIREMENTS FOR <br />ELECTRICAL EQUIPMENT, PIPING, DUCTWORK, ETC. REQUIRED FOR THIS PROJECT. WHERE <br />REQUIRED, THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING <br />RESTRAINTS TO RESIST THE EARTHQUAKE EFFECTS ON THE ELECTRICAL SYSTEM. THE <br />REQUIREMENTS FOR THESE RESTRAINTS ARE FOUND IN THE CALIFORNIA BUILDING CODE, <br />2022. <br />THE ELECTRICAL CONTRACTOR SHALL RETAIN THE SERVICES OF A PROFESSIONAL <br />STRUCTURAL ENGINEER REGISTERED IN THE STATE OF CALIFORNIA TO DESIGN SEISMIC <br />RESTRAINT ELEMENTS REQUIRED FOR THIS PROJECT. THE ENGINEER'S COMPUTATIONS, <br />BEARING HIS PROFESSIONAL SEAL, SHALL ACCOMPANY SHOP DRAWINGS WHICH SHOW <br />CALIFORNIA BUILDING CODE, 2022 COMPLIANCE. COMPUTATIONS AND SHOP DRAWINGS <br />SHALL BE SUBMITTED FOR REVIEW PRIOR TO THE PURCHASING OF MATERIALS, EQUIPMENT, <br />SYSTEMS AND ASSEMBLIES. <br />THE ELECTRICAL CONTRACTOR SHALL INCLUDE SHOP DRAWINGS OF THE SPECIFIC METHODS <br />OF SEISMIC RESTRAINT TO BE USED FOR THIS PROJECT PRIOR TO INSTALLATION OF PIPING, <br />DUCTWORK AND EQUIPMENT. <br />INTERNAL SEISMIC RESTRAINT ELEMENTS OF MANUFACTURED EQUIPMENT SHALL BE <br />CERTIFIED BY A PROFESSIONAL ENGINEER RETAINED BY THE MANUFACTURER. SUCH <br />CERTIFICATE APPLIES ONLY TO INTERNAL ELEMENTS OF THE EQUIPMENT. ALL EQUIPMENT <br />ANCHORAGE REQUIREMENTS SHALL BE COORDINATED WITH THE BUILDING STRUCTURE AND <br />SHALL BE COMPATIBLE THERETO. ALL SUCH ANCHORAGE SHALL BE REVIEWED BY THE <br />PROJECT'S ELECTRICAL ENGINEER PRIOR TO INSTALLATION. <br />THE PROFESSIONAL ENGINEER RETAINED BY THE ELECTRICAL CONTRACTOR FOR SEISMIC <br />RESTRAINT CALCULATIONS AND DESIGN SHALL VISIT THE JOB SITE UPON COMPLETION OF THE <br />SEISMIC RESTRAINT INSTALLATION. THIS ENGINEER SHALL PROVIDE IN WRITING, <br />VERIFICATION OF COMPLIANCE WITH THE APPROVED SEISMIC SUBMITTAL. THIS ENGINEER <br />SHALL ALSO PERFORM ANY SPECIAL INSPECTIONS REQUIRED BY THE CALIFORNIA <br />BUILDING CODE, 2022. THIS VERIFICATION SHALL BEAR THE ENGINEER'S PROFESSIONAL SEAL. <br />JOB SITE INSPECTION BY OTHER THAN THIS ENGINEER IS NOT ACCEPTABLE. <br />REVIEW OF THE SEISMIC DESIGN AND SHOP DRAWINGS BY THE PROJECT'S ELECTRICAL <br />ENGINEER, STRUCTURAL ENGINEER OR ARCHITECT SHALL NOT RELIEVE THE CONTRACTOR <br />OF THEIR RESPONSIBILITY TO COMPLY WITH THE SEISMIC OR ANY OTHER REQUIREMENTS OF <br />THE CALIFORNIA BUILDING CODE, 2022. <br />SPECIFICATIONS NOTES <br />E-0.1A <br />SPECIFICATIONS NOTES