Laserfiche WebLink
CONDUIT K12 <br />ELECTRICAL CONDUIT BEYOND. <br />SEE ELECTRICAL PLANS <br />6' <br />( <br />M <br />I <br />N <br />) <br />CONCRETE PAD <br />1 2 3 <br />4 <br />1' <br />(T <br />Y <br />P <br />) <br />7SEE NOTE <br />2 (TYP) <br />5 6 <br />1' <br />- <br />6 <br />" <br />( <br />M <br />I <br />N <br />) <br />24 <br />" <br />( <br />M <br />I <br />N <br />) <br />AA <br />IN PLANTER <br />AREAS = 3" <br />FINISHED <br />SURFACE <br />CONDUIT C1 <br />NOTES: <br />1.TERMINAL BLOCK AND TEMPORARY SUPPORT WILL BE REMOVED ONCE CHARGERS <br />ARE INSTALLED. <br />2.SECURELY FASTEN PVC CONDUIT TO CONDUIT SUPPORT WITH 1/4" WIDE UV <br />STABILIZED NYLON CABLE TIES. PROVIDE 1 TIE EVERY 12". FIELD FIT CONDUIT <br />ATTACHMENT AND CONFIGURATION AS NEEDED TO FIT WITHIN THE 3.2'' X 3.2'' <br />OPENING AS SHOWN IN SECTION A-A <br />3.PARTS INCLUDED IN THE BILL OF MATERIALS ARE FOR 1 TEMPORARY TERMINAL <br />BLOCK ONLY. SEE ELECTRICAL CONDUIT PLAN FOR LOCATION AND COUNT. <br />BILL OF MATERIALS (1 UNIT) <br />REFERENCE <br />NUMBER ITEM QUANTITY <br />1 VYNCKIER VM554 ENCLOSURE 1 EA <br />2 VYNCKIER BACKING PLATE VMBP55A 1 EA <br />3 TERMINAL BLOCK BUSSMANN 14004-6, 90A, #4-14 AWG <br />CU, 600 VAC 1 EA <br />4 EATON B-LINE B22SH120 HDG, 12GA, 10' LENGTHS 1 EA <br />5 B-LINE 1/4 X 1.25" 20 HHCS ZINC 2 EA <br />6 B-LINE SPRING NUT, N224, 1/4 - 20 2 EA <br />7 UV STABILIZED NYLON CABLE TIES (1/4" WIDTH)5 EA <br />10 <br />" <br />2' <br />4 <br />2' <br />2' <br />1' <br />11" <br />C1 RISER <br />PAYMENT KIOSK <br />SECTION A-A <br />(K12) <br />1'-1" <br />BASEPLATE TO BE <br />INSTALLED BY OTHERS <br />SEE DETAIL [B/R1.1] <br />1" <br />FINISHED <br />SURFACE <br />PVC ELECTRICAL <br />CONDUIT RISER <br />ELECTRICAL CONDUIT BEYOND. <br />SEE ELECTRICAL PLANS <br />6' <br />( <br />M <br />I <br />N <br />) <br />CONCRETE PAD <br />1 2 3 <br />4 <br />NOTES: <br />1.TERMINAL BLOCK AND TEMPORARY SUPPORT WILL BE REMOVED ONCE CHARGERS <br />ARE INSTALLED. <br />2.SECURELY FASTEN PVC CONDUIT TO CONDUIT SUPPORT WITH 1/4" WIDE UV <br />STABILIZED NYLON CABLE TIES. PROVIDE 1 TIE EVERY 12". <br />3.PARTS INCLUDED IN THE BILL OF MATERIALS ARE FOR 1 TEMPORARY TERMINAL <br />BLOCK ONLY. SEE ELECTRICAL CONDUIT PLAN FOR LOCATION AND COUNT. <br />1' <br />(T <br />Y <br />P <br />) <br />7SEE NOTE <br />2 (TYP) <br />5 6 <br />1' <br />- <br />6 <br />" <br />( <br />M <br />I <br />N <br />) <br />24 <br />" <br />( <br />M <br />I <br />N <br />) <br />10 <br />" <br />2' <br />AA <br />IN PLANTER <br />AREAS = 3" <br />CONCRETE CURB, <br />WHEN APPLICABLE, <br />SEE PLAN <br />BILL OF MATERIALS (1 UNIT) <br />REFERENCE <br />NUMBER ITEM QUANTITY <br />1 VYNCKIER VM554 ENCLOSURE 1 EA <br />2 VYNCKIER BACKING PLATE VMBP55A 1 EA <br />3 TERMINAL BLOCK BUSSMANN 14004-6, 90A, #4-14 AWG <br />CU, 600 VAC 1 EA <br />4 EATON B-LINE B22SH120 HDG, 12GA, 10' LENGTHS 1 EA <br />5 B-LINE 1/4 X 1.25" 20 HHCS ZINC 2 EA <br />6 B-LINE SPRING NUT, N224, 1/4 - 20 2 EA <br />7 UV STABILIZED NYLON CABLE TIES (1/4" WIDTH)5 EA <br />FINISHED <br />SURFACE <br />(3) #4 EACH WAY <br />CENTERED IN <br />SLAB <br />4 <br />2' <br />2' <br />1' <br />SECTION A-A <br />EV CHARGER <br />1' <br />PVC <br />ELECTRICAL <br />CONDUIT <br />RISER <br />CONDUIT K1 <br />ELECTRICAL CONDUIT BEYOND. <br />SEE ELECTRICAL PLANS <br />6' <br />( <br />M <br />I <br />N <br />) <br />CONCRETE PAD <br />1 2 3 <br />4 <br />1' <br />(T <br />Y <br />P <br />) <br />7SEE NOTE <br />2 (TYP) <br />5 6 <br />1' <br />- <br />6 <br />" <br />( <br />M <br />I <br />N <br />) <br />24 <br />" <br />( <br />M <br />I <br />N <br />) <br />AA <br />IN PLANTER <br />AREAS = 3" <br />CONCRETE CURB, <br />WHEN APPLICABLE, <br />SEE PLAN <br />FINISHED <br />SURFACE <br />CONDUIT C2 <br />NOTES: <br />1.TERMINAL BLOCK AND TEMPORARY SUPPORT WILL BE REMOVED ONCE CHARGERS <br />ARE INSTALLED. <br />2.SECURELY FASTEN PVC CONDUIT TO CONDUIT SUPPORT WITH 1/4" WIDE UV <br />STABILIZED NYLON CABLE TIES. PROVIDE 1 TIE EVERY 12". FIELD FIT CONDUIT <br />ATTACHMENT AND CONFIGURATION AS NEEDED TO FIT WITHIN THE 3.2'' X 3.2'' <br />OPENING AS SHOWN IN SECTION A-A <br />3.PARTS INCLUDED IN THE BILL OF MATERIALS ARE FOR 1 TEMPORARY TERMINAL <br />BLOCK ONLY. SEE ELECTRICAL CONDUIT PLAN FOR LOCATION AND COUNT. <br />BILL OF MATERIALS (1 UNIT) <br />REFERENCE <br />NUMBER ITEM QUANTITY <br />1 VYNCKIER VM554 ENCLOSURE 1 EA <br />2 VYNCKIER BACKING PLATE VMBP55A 1 EA <br />3 TERMINAL BLOCK BUSSMANN 14004-6, 90A, #4-14 AWG <br />CU, 600 VAC 1 EA <br />4 EATON B-LINE B22SH120 HDG, 12GA, 10' LENGTHS 1 EA <br />5 B-LINE 1/4 X 1.25" 20 HHCS ZINC 2 EA <br />6 B-LINE SPRING NUT, N224, 1/4 - 20 2 EA <br />7 UV STABILIZED NYLON CABLE TIES (1/4" WIDTH)5 EA <br />10 <br />" <br />2' <br />2' <br />2' <br />1' <br />11" <br />C2 RISER <br />PAYMENT KIOSK <br />SECTION A-A <br />(K1) <br />1'-1" <br />4 <br />PVC <br />ELECTRICAL <br />CONDUIT <br />RISER <br />SHEETSOF <br />SHEET NO. <br />SCALE AS NOTED <br />DATE: <br />CH. BY: <br />DR. BY: <br />REF. & REV. <br />CONSULTANT <br />06-17-2025 12 <br />CR <br />GSKAISER FOUNDATION HEALTH PLAN <br />CHARGE READY PROGRAM <br />SOUTHERN CALIFORNIA EDISON <br />Dr <br />a <br />w <br />i <br />n <br />g <br />: <br /> <br />P: <br />\ <br />2 <br />2 <br />1 <br />\ <br />2 <br />2 <br />1 <br />- <br />0 <br />2 <br />2 <br />3 <br />\ <br />S <br />i <br />t <br />e <br />\ <br />0 <br />0 <br />0 <br />0 <br />2 <br />1 <br />1 <br />2 <br />3 <br />0 <br />9 <br />_ <br />K <br />F <br />H <br />P <br />\ <br />C <br />D <br /> <br />P <br />h <br />a <br />s <br />e <br />\ <br />P <br />r <br />o <br />d <br />u <br />c <br />t <br />i <br />o <br />n <br />D <br />r <br />a <br />w <br />i <br />n <br />g <br />s <br />\ <br />21 <br />1 <br />2 <br />3 <br />0 <br />9 <br />_ <br />K <br />F <br />H <br />P <br />_ <br />d <br />t <br />0 <br />2 <br />. <br />d <br />w <br />g <br />; <br />La <br />y <br />o <br />u <br />t <br />1 <br /> <br />( <br />2 <br />) <br /> - <br /> <br />BC <br />F <br />. <br />c <br />t <br />b <br />Pl <br />o <br />t <br /> <br />b <br />y <br />: <br /> <br />dp <br />a <br />r <br />t <br />i <br />d <br />a <br /> <br /> <br />Oc <br />t <br /> <br />2 <br />3 <br />, <br /> <br /> <br />2 <br />0 <br />2 <br />5 <br /> <br />- <br /> <br />1 <br />: <br />5 <br />6 <br />p <br />m <br />00002112309 <br />Date Signed: <br />06-17-2025 <br />PROJECT LOCATION: 3401 S HARBOR BLVD., SANTA ANA, CA 92704 <br />8CONDUIT SECTIONS AND DETAILS <br />E2.1 <br />A <br />E2.1 <br />PAYMENT KIOSK CONCRETE PAD AND TEMPORARY TERMINAL BLOCK <br />NOT TO SCALE <br />NOTE: <br />1.SEE NOTES ON SHEET E2.0 <br />B <br />E2.1 <br />EV CHARGER CONCRETE PAD AND TEMPORARY TERMINAL BLOCK <br />NOT TO SCALE <br />C <br />E2.1 <br />EV CHARGER CONCRETE PAD AND TEMPORARY TERMINAL BLOCK WITH ADDED WIRELESS ACCESS POINT <br />NOT TO SCALE