Laserfiche WebLink
7 <br />CLOSED EXTENDED <br />8. Install O-rings on HLL cable. Then, take one end of 3/8” cable and create a loop around the thimble. See <br />Appendix A (pgs. 8-9) for fist grip installation instructions. Repeat on opposite end of system. <br />9. Tighten turnbuckle evenly on both ends so there is 6” of slack measured vertically at midpoint of span. <br />Qualified Person must make final determination regarding sufficient cable slack. <br />6. Attach one end of turnbuckle to Metal Energy Absorber at one end of <br />system as shown, and tighten until at least 1 full thread is visible. <br />7. Place wire rope thimble on other end of turnbuckle. Tighten bolt until at least 1 full thread is visible. Attach <br />second steel shackle and thimble to anchor point or Metal Energy Absorber at opposite end of system (second <br />turnbuckle is not used). <br />Slack: 6” <br />Tightening bolts on the Absorbinator system <br />YES NO <br />3. Attach Metal Energy Absorber to anchor point using provided steel <br />shackle as shown. If system is more than 60’, attach second Metal <br />Energy Absorber to anchor point at other end of system. Tighten <br />shackle until at least 1 full thread is visible. <br />4. Make any other necessary attachments to anchorage connectors. <br />*In the event that a 90° corner is needed, two HLL systems may be <br />attached to a single anchor point as shown. <br />5. Adjust turnbuckle(s) to extended position (see below).