My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
109 E 4th St - Plan
PBA
>
Building
>
ProjectDox
>
F
>
Fourth St
>
109 E Fourth St
>
109 E 4th St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2026 5:00:13 AM
Creation date
1/30/2026 5:00:06 AM
Metadata
Fields
Template:
Plan
Permit Number
20186851
30149311
40140758
101124975
Full Address
109 E Fourth St
Street Number
109
Street Direction
E
Street Name
Fourth
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
C <br />TS <br />OVERRIDE SWITCH <br />TO LIGHTSA-1 <br />A-3 <br />TIME CLOCK <br />120V AC <br />2-HOUR <br />TIMER SWITCH <br />LIGHTING CONTROL DIAGRAM <br />TO SIGNAGE <br />LIGHTING FIXTURE SCHEDULE <br />TYPE DESCRIPTION LAMP VOLT WATT <br />L1 2X4 RECESSED LED TROFFER LIGHT, DIMMABLE <br />LITHONIA 2GTL4 SERIES OR APPROVED EQUAL LED 120 43 <br />L2 6" LED RECESSED DOWNLIGHT, DIMMABLE <br />LITHONIA LDN6 SERIES OR APPROVED EQUAL LED 120 18 <br />L3 LED PENDANT FIXTURE, DIMMABLE <br />WAC LIGHTING DWELED TIC TOC SERIES OR APPROVED EQUAL LED 120 15 <br />EE LIGHT FIXTURE WITH 90 MINUTES EMERGENCY BATTERY PACK <br />VERIFY WITH MANUFACTURER FOR OPTION/INVERTER IF NOT AVAILABLE ---120 --- <br />EM EMERGENCY LED LIGHT WITH 90 MINUTES BATTERY PACK <br />LITHONIA EU2L (WALL), ELR2 (CEILING), ELAQWP (OUTDOOR) SERIES OR EQUIVALENT ---120 --- <br />X LED EXIT SIGN WITH 90 MINUTES BATTERY PACK <br />LITHONIA EXR LED M6 OR EQUIVALENT ---120 --- <br />120V, SINGLE POLE, MAX 3% VOLTAGE DROP <br />LENGTH OF RUN <br />COPPER <br />COPPER <br />COPPER <br />COPPER <br />COPPER <br />ALUMINUM <br />ALUMINUM <br />AMP LOAD200'150'100'50'25' <br />14 <br />12 <br />10 <br />1 <br />1/0 <br />3/0 <br />250 <br />12 <br />12 <br />10 <br />1 <br />1/0 <br />3/0 <br />250 <br />10 <br />8 <br />6 <br />1 <br />2/0 <br />3/0 <br />300 <br />8 <br />6 <br />4 <br />2/0 <br />4/0 <br />300 <br />600 <br />6 <br />4 <br />4 <br />4/0 <br />300 <br />500 <br />900 <br />15 AMP <br />20AMP <br />30 AMP <br />100 AMP <br />100 AMP <br />200 AMP <br />200 AMP <br />NOTE: <br />THE MAXIMUM COMBINED VOLTAGE DROP ON BOTH INSTALLED FEEDER CONDUCTORS AND BRANCH CIRCUIT <br />CONDUCTORS TO THE FARTHEST CONNECTED LOAD OR OUTLET SHALL NOT EXCEED 5 PERCENT. <br />EMERGENCY EXIT ILLUMINATION NOTES <br />1.FIXTURES WITH 90 MIN. EMERGENCY BATTERY BACKUP SHALL BE WIRED <br />AHEAD OF ANY CONTROL IN COMPLIANCE WITH [2022 CEC 700.12(I)(2)(3)(A)]. <br />2.THE MEANS OF EGRESS SERVING A ROOM OR SPACE SHALL BE ILLUMINATED <br />AT ALL TIMES THAT THE ROOM OR SPACE IS OCCUPIED. [2022 CBC 1008.2] <br />3.THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR A DURATION <br />OF NOT LESS THAN 90 MINUTES AND SHALL CONSIST OF STORAGE <br />BATTERIES, UNIT EQUIPMENT OR AN ONSITE GENERATOR. [2022 CBC 1008.3.4] <br />4.EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL <br />ILLUMINATION THAT IS NOT LESS THAN AN AVERAGE OF 1 FC, AND A MIN AT <br />ANY POINT OF 0.1 FC MEASURED ALONG THE PATH OF EGRESS AT FLOOR <br />LEVEL. ILLUMINATION LEVELS SHALL BE PERMITTED TO DECLINE TO 0.6 FC <br />AVERAGE AND A MIN AT ANY POINT OF 0.06 FC AT THE END OF THE <br />EMERGENCY LIGHTING TIME DURATION. A MAX-TO-MIN ILLUMINATION <br />UNIFORMITY RATIO OF 40 TO 1 SHALL NOT BE EXCEEDED. [2022 CBC 1008.3.5] <br />5.EXITS AND EXIT ACCESS DOORS SHALL BE MARKED BY AN APPROVED EXIT <br />SIGN READILY VISIBLE FROM ANY DIRECTION OF EGRESS TRAVEL. EXIT SIGN <br />PLACEMENT SHALL BE SUCH THAT ANY POINT IN AN EXIT ACCESS CORRIDOR <br />OR EXIT PASSAGEWAY IS WITHIN 100 FT OR THE LISTED VIEWING DISTANCE <br />OF THE SIGN, WHICHEVER IS LESS, FROM THE NEAREST VISIBLE EXIT SIGN. <br />[2022 CBC 1013.1] <br />6.TACTILE EXIT SIGNS SHALL BE PROVIDED WITH APPROPRIATE WORDS AT <br />EXIT DOORS LEADING TO ENCLOSED EXIT STAIRWAYS AND EXIT DOORS <br />LEADING TO OUTSIDE. [2022 CBC 1013.4] <br />7.EMERGENCY LIGHTING UNITS SHALL BE EQUIPPED WITH FACTORY <br />INSTALLED INTEGRAL TEST SWITCHES. <br />NOTES: <br />1.FIXTURE SHALL HAVE MIN. OF 10 YEARS MANUFACTURER WARRANTY ON ALL COMPONENTS. <br />2.FIXTURES SHALL HAVE APPROPRIATE U.L. LABEL (i.c., DAMP OR WET) AS REQUIRED BY CODES AND ORDINANCES. <br />3.FIXTURES SHALL INCLUDE ALL ACCESSORIES FOR INSTALLATION ACCORDING TO MANUFACTURER'S SHOP <br />DRAWINGS AND AS REQUIRED BY CODES AND LOCAL ORDINANCES. <br />4.PRIOR TO ORDERING ANY LIGHTING EQUIPMENT, THE CONTRACT OR SHALL COORDINATE ALL FIXTURE <br />LOCATIONS WITH ARCHITECTURAL REFLECTED CEILING PLANS AND CEILING CAVITY DEPTHS. <br />5.ALL LAMPS SHALL BE PROVIDED AND INSTALLED ACCORDING TO THE ATTACHED FIXTURE SCHEDULE AND <br />SPECIFICATIONS. ENSURE COMPATIBILITY BETWEEN FIXTURE, LAMP(S) AND BALLAST(S). <br />6.CONTRACTOR SHALL VERIFY FIXTURE VOLTAGES AND CEILING TRIM COMPATIBILITY PRIOR TO ORDERING <br />FIXTURE. <br />7.PROVIDE APPROVED FIRE-RATED ENCLOSURES FOR ALL LIGHTING FIXTURES LOCATED IN FIRE-RATED CEILINGS. <br />8.LIGHTING FIXTURE CATALOG NUMBERS ARE SERIES TYPE ONLY. PROVIDE ALL NECESSARY HARDWARE AS <br />REQUIRED BY THE SPECIFICATIONS, DRAWINGS, AND PROJECT CONDITIONS FOR A COMPLETE INSTALLATION. <br />9.ALL FIXTURES SHALL BE ORDERED WITH APPROPRIATE BALLAST(S) THAT HAVE U.L. AND CBM LABELS. PROVIDE <br />MULTIPLE BALLASTS FOR DUAL-LEVEL SWITCHING AND WIRING AS INDICATED ON THE PLANS. <br />10.ENSURE COMPATIBILITY OF ALL LIGHTING SYSTEM COMPONENTS, ESPECIALLY DIMMED SYSTEMS. FIXTURES, <br />LAMPS, BALLAST(S), AND DIMMING SYSTEMS/INDIVIDUAL CONTROLS MUST BE FACTORY CERTIFIED COMPATIBLE <br />FOR FULL RANGE OF DIMMING COMPATIBILITY. <br />11.LIGHTING FIXTURE MANUFACTURER & MODEL IS FOR REFERENCE ONLY. FIXTURE SHALL BE SELECTED BY <br />ARCHITECT. POWER AND QUALITY SHALL BE SPECIFICATION GRADE. <br />SINGLE LINE DIAGRAM NOTES <br />1.CONTRACTOR/ELECTRICIAN TO FIELD VERIFY ACTUAL SITE CONDITION <br />/EXACT SERVICE ENTRANCE AND SHALL NOTIFY EOR(S) ANY DISCREPANCY <br />WITH THE PLAN PRIOR TO BIDDING. <br />2.CONTRACTOR TO VERIFY ALL EQUIPMENT DIMENSIONS AND CLEARANCES <br />WITH FIELD CONDITION PRIOR TO ORDERING EQUIPMENT. <br />3.ALL EQUIPMENT TO BE LISTED BY A RECOGNIZED TESTING AGENCY. <br />TERMINALS TO BE RATED FOR ALUMINUM AND COPPER WIRE. <br />4.CONTRACTOR TO OBTAIN A FAULT CURRENT LETTER FROM UTILITY <br />COMPANY PRIOR TO PURCHASE OF ANY EQUIPMENT (IF ANY) FOR AIC <br />VERIFICATION. EQUIPMENT CUTSHEETS AND FAULT CURRENT LETTER TO BE <br />PROVIDED UPON INSPECTION. <br />5.IF APPLICABLE, ALL NEW CIRCUIT BREAKERS INSTALLED ON EXISTING <br />PANEL/SWITCHBOARD SHALL MATCH THE HIGHEST EXISTING AIC RATED <br />BREAKER WITHIN THAT PANEL/BOARD. INSPECTOR TO VERIFY HIGHEST AIC <br />RATING AT THE SITE. <br />6.MAIN SERVICE DISCONNECT AMPERAGE MUST BE PERMANENTLY MARKED <br />7.ALL SYSTEM TO BE FULLY RATED SYSTEM. IF SYSTEM IS SERIES RATED, ALL <br />COMPONENTS MUST BE FROM THE SAME MANUFACTURER. LISTED BREAKER <br />COMBINATIONS SHALL BE AVAILABLE TO THE AUTHORITY HAVING <br />JURISDICTION UPON REQUEST. <br />8.IF APPLICABLE, ALL EQUIPMENT LABELED/IDENTIFIED AS EXISTING, ARE <br />SUBJECT TO FIELD VERIFICATION. <br />9.ARC-FLASH HAZARD WARNING FIELD MARKING TO BE PROVIDED ON <br />ELECTRICAL EQUIPMENT, SUCH AS SWITCHBOARDS, PANEL BOARDS, METER <br />SOCKET ENCLOSURES AND MCC THAT ARE IN OTHER THAN DWELLING UNITS. <br />[2022 CEC 110.16, 110.21(B)] <br />10.SERVICE EQUIPMENT SHALL BE FIELD MARKED WITH THE MAXIMUM <br />AVAILABLE FAULT CURRENT. [2022 CEC 110.24] <br />SINGLE LINE DIAGRAM <br />FEEDER CHART <br />(E)/(N)FEEDER SIZE <br />S1.2K (E)(4) 4#600, #350GND- 4"C <br />200 (N)4#350, #4GND- 3"C <br />NOTE: <br />(E) FEEDERS TO BE FIELD VERIFIED AND REMAIN AS-IS U.O.N. <br /># <br />S(Override) = LIGHTING OVERRIDE <br />SWITCH, AT FRONT DOOR. <br />TC = LIGHTS TIME CLOCK WITH <br />OVERRIDE ON/OFF CONTROL <br />SPECIFIC NOTES: <br />DESIGNATED NON EMERGENCY <br />LIGHTING CIRCUITS SHALL BE <br />CONTROLLED BY 24 HR TIME CLOCK <br />THROUGH MULTI-POLE CONTACTOR. <br />TIME CLOCK SHALL INCORPORATE AN <br />AUTOMATIC HOLIDAY "SHUT-OFF" <br />FEATURE. INTERMATIC ET2800 <br />SERIES (INDOOR)/ET8000 SERIES <br />(OUTDOOR) OR EQUIV. <br />(E) FROM MAIN <br />SWITCHBOARD "MSA2" <br />(ELECTRICAL ROOM) <br />(E) <br />200A <br />3P <br />(E) MAIN SWITCHBOARD "MSA3" <br />1200A, 120/208V, 3Ø, 4W <br />65K AIC RATING, NEMA 1 ENCLOSURE <br />(E) <br />1200A <br />3P <br />M <br />(N) PANEL <br />"A" <br />200 <br />SELF TAPPING <br />SCREWS <br />STANDARD COLORS: <br />1. NORMAL POWER - BLACK BACKGROUND, WHITE LETTERS <br />2. EMERGENCY POWER - RED BACKGROUND, WHITE LETTERING <br />NAMEPLATES ARE REQUIRED ON ALL PANELBOARDS, STARTERS <br />AND DISCONNECT SWITCHES. <br />PANELBOARD <br />PANEL "X" <br />PANELBOARD <br />DESIGNATION <br />ALL PANELS SHALL BE LABELED ON INSIDE OF DOOR WITH <br />LIST OF CIRCUITS AND THEIR APPROPRIATE NAMES. <br />3" <br />1" <br />EACH PANEL SCHEDULE TO INDICATE THE SOURCE OF POWER <br />TO THE PANEL. THE LABEL SHALL BE PERMANENTLY AFFIXED. <br />NAMEPLATE <br />(TYPICAL) <br />ENGRAVED LAMACOID, <br />5/32 INCH LETTERS <br />PANEL BOARD NAMEPLATE DETAIL <br />SCALE <br />NTS <br />1 OCCUPANCY SENSOR CONTROL DETAIL <br />SCALE <br />NTS <br />3120V GFCI BREAKER WIRING DIAGRAM <br />SCALE <br />NTS <br />2 <br />S1.2K <br />D=180' <br />%VD=1.70 <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />SHEET TITLE: <br />DATE: SCALE: <br />AR <br />T <br />E <br /> <br />R <br />E <br />S <br />T <br />A <br />U <br />R <br />A <br />N <br />T <br /> <br />03/03/2025 <br />PLOT DATE: 10/24/2025 2:42:50 PM <br />CD <br />I <br /> <br />Ci <br />r <br />c <br />a <br /> <br />D <br />o <br />m <br />i <br />n <br />i <br /> <br />I <br />n <br />t <br />e <br />r <br />n <br />a <br />t <br />i <br />o <br />n <br />a <br />l <br />, <br /> <br />I <br />n <br />c <br />. <br />En <br />g <br />i <br />n <br />e <br />e <br />r <br />i <br />n <br />g <br /> <br />- <br /> <br />C <br />o <br />n <br />s <br />u <br />l <br />t <br />i <br />n <br />g <br />98 <br />9 <br />0 <br /> <br />R <br />e <br />s <br />e <br />a <br />r <br />c <br />h <br /> <br />D <br />r <br />. <br /> <br />S <br />u <br />i <br />t <br />e <br /> <br />1 <br />0 <br />0 <br />, <br /> <br />I <br />r <br />v <br />i <br />n <br />e <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />6 <br />1 <br />8 <br />Ph <br />o <br />n <br />e <br /> <br />( <br />9 <br />4 <br />9 <br />) <br /> <br />3 <br />3 <br />6 <br />- <br />6 <br />6 <br />3 <br />6 <br /> <br />| <br /> <br />d <br />k <br />a <br />n <br />g <br />@ <br />c <br />d <br />i <br />e <br />n <br />g <br />. <br />c <br />o <br />m <br />10 <br />9 <br /> <br />E <br /> <br />4 <br />T <br />H <br /> <br />S <br />T <br />. <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />DRAWN: CHECKED: <br />PL <br />A <br />N <br /> <br />C <br />H <br />E <br />C <br />K <br /> <br />R <br />E <br />V <br />. <br /> <br />0 <br />5 <br />/ <br />1 <br />2 <br />/ <br />2 <br />0 <br />2 <br />5 <br />FI <br />E <br />L <br />D <br /> <br />C <br />H <br />A <br />N <br />G <br />E <br /> <br />0 <br />9 <br />/ <br />0 <br />5 <br />/ <br />2 <br />0 <br />2 <br />5 <br />PL <br />A <br />N <br /> <br />C <br />H <br />E <br />C <br />K <br /> <br />R <br />E <br />V <br />. <br /> <br />0 <br />9 <br />/ <br />2 <br />9 <br />/ <br />2 <br />0 <br />2 <br />5 <br />N.T.S. <br />E001 <br />SINGLE LINE <br />DIAGRAM/ <br />SCHEDULES <br />J.L.K.P.
The URL can be used to link to this page
Your browser does not support the video tag.