Laserfiche WebLink
UP <br />DNUP <br />95.5000 <br />131.0000 <br />126.0000 <br />109.7500 <br />82.0000 <br />58.0000 <br />189.0003 <br />77.0000 <br />83.0000 <br />457.0000 <br />180.0000 <br />5.9373FIRE AREA 1 - W2 <br />30.1873FIRE AREA 4 - W2 <br />11.1632 <br />DAYLIGHT CONTROL EXCEPTION NOTES: <br />DAYLIGHT CONTROL: COMBINED TOTAL GENERAL LIGHTING POWER IN <br />PRIMARY/SECONDARY SIDELIT DAYLIT ZONE IS LESS THAN 120 WATTS. NO <br />DAYLIGHT CONTROL REQUIRED. [2022 CENC130.1(D)EXCEPTION(3)] <br />LIGHTING PLAN <br />1.EMERGENCY/NL AND EXIT FIXTURES TO BE CONNECTED TO NEARBY ROOM <br />LIGHTING CIRCUIT AHEAD OF LOCAL SWITCH. [2022 CEC 700.12(I)(2)(3)(A)]. <br />2.CONTRACTOR TO VERIFY FINAL LOCATION OF SWITCH/DIMMER/CONTROL <br />PACK WITH THE ARCHITECT/OWNER PRIOR TO ROUGH-IN. <br />3.INTERLOCK RESTROOM LIGHT WITH EXHAUST FAN AND PROVIDE MANUAL <br />MOTOR SWITCH IF NOT PLUG/BUILT-IN. <br />4.WIRE THRU CONTACTOR & TIME CLOCK FOR SIGNAGE LIGHTING CONTROL. <br />#KEYED PLAN NOTES: <br />GENERAL NOTES: <br />1.ELECTRICAL EQUIPMENT SHALL BE LISTED BY U.L. OR CITY RECOGNIZED <br />ELECTRICAL TESTING LABORATORY OR APPROVED BY THE CITY <br />DEPARTMENT. <br />2.ALL ELECTRICAL WORK SHALL COMPLY WITH THE [2022 CEC]. <br />3.WIRE SIZE SHALL NOT BE LESS THAN CORRESPONDING CIRCUIT BREAKER <br />RATING AS REQUIRED. [2022 CEC TABLE 310.16] <br />4.CONDUIT SHALL BE SIZED IN ACCORDANCE WITH THE [2022 CEC ANNEX C]. <br />5.CONTRACTOR/ELECTRICIAN TO FIELD VERIFY ACTUAL SITE CONDITION <br />/EXACT SERVICE ENTRANCE AND SHALL NOTIFY EOR(S) ANY DISCREPANCY <br />WITH THE PLAN PRIOR TO BIDDING. <br />6.ALL ITEMS LABELED/IDENTIFIED AS EXISTING (IF ANY) ARE SUBJECT TO <br />FIELD VERIFICATION. VERIFY EXISTING CONDITION AND RE-USE. IF NOT <br />EXISTING, PROVIDE PER PLAN. <br />7.OBTAIN APPROVAL ON LOCATION OF SWITCH/DIMMER/SENSOR WITH <br />ARCHITECT/OWNER AT SITE PRIOR TO ROUGH-IN. <br />8.SIGNAGE WILL REQUIRE SEPARATE PERMIT AND SUBMITTAL. <br />9.REFER TO EMERGENCY EXIT ILLUMINATION NOTES FOR EMERGENCY <br />LIGHTING REQUIREMENTS. <br />10.IN OFFICES 250 SQUARE FEET OR SMALLER, MULTIPURPOSE ROOMS OF <br />LESS THAN 1,000 SQUARE FEET, CLASSROOMS OF ANY SIZE, CONFERENCE <br />ROOMS OF ANY SIZE, AND RESTROOMS OF ANY SIZE, LIGHTING SHALL BE <br />CONTROLLED WITH OCCUPANT SENSING CONTROLS TO AUTOMATICALLY <br />SHUT OFF ALL OF THE LIGHTING IN 20 MINUTES OR LESS AFTER THE <br />CONTROL ZONE IS UNOCCUPIED. [2022 CENC 130.1(C)(5)] <br />A.IN AREAS W/ MULTI-LEVEL LIGHTING CONTROLS, THE OCCUPANT <br />SENSING CONTROLS SHALL FUNCTION AS A PARTIAL-ON OCCUPANT <br />SENSING CONTROLS CAPABLE OF AUTOMATICALLY ACTIVATING <br />BETWEEN 50 AND 70 PERCENT OF CONTROLLED LIGHTING POWER <br />B.IN AREAS W/O MULTILEVEL LIGHTING CONTROLS, THE OCCUPANT <br />SENSING CONTROLS SHALL FUNCTION AS A VACANCY SENSING <br />CONTROLS, WHERE ALL LIGHTING RESPONDS TO A MANUAL ON INPUT <br />ONLY. <br />11.IN CORRIDORS AND STAIRWELLS, LIGHTING SHALL BE CONTROLLED BY <br />OCCUPANT SENSING CONTROLS THAT SEPARATELY REDUCE THE LIGHTING <br />POWER IN EACH SPACE BY AT LEAST 50 PERCENT WHEN THE SPACE IS <br />UNOCCUPIED. THE OCCUPANT SENSING CONTROLS SHALL BE CAPABLE OF <br />AUTOMATICALLY TURNING THE LIGHTING FULLY ON ONLY IN THE <br />SEPARATELY CONTROLLED SPACE, AND SHALL BE AUTOMATICALLY <br />ACTIVATED FROM ALL DESIGNED PATHS OF EGRESS. [2022 CENC <br />130.1(C)(6)(C)] <br />12.TIME CLOCK SHALL INCORPORATE A MANUAL OVERRIDE LIGHTING <br />CONTROL THAT COMPLIES WITH SECTION 130.1(A); AND ALLOWS THE <br />LIGHTING TO REMAIN ON FOR NO MORE THAN 2 HOURS WHEN AN <br />OVERRIDE IS INITIATED; AND SHALL INCORPORATE AN AUTOMATIC <br />HOLIDAY "SHUT-OFF" FEATURE THAT TURNS OFF ALL LOADS FOR AT LEAST <br />24 HOURS, AND THEN RESUMES THE NORMALLY SCHEDULED OPERATION. <br />[2022 CENC 130.1(C)(3)&(4)] <br />PATIO <br />KEY PLAN <br />SCOPE OF <br />WORK <br />108 <br />OUTDOOR DINING PATIO <br /> <br />106 <br />MEN'S RR <br /> <br />105 <br />WOMEN'S RR <br /> <br />104 <br />STORAGE <br /> <br />101 <br />DINNING AREA <br /> <br />107 <br />KITCHEN AREA <br /> <br />103 <br />HALLWAY <br /> <br />102 <br />SERVICE AREA <br /> <br />X1 <br />L2 L2 L2 L2 <br />L3 L3 <br />L3 <br />L3 <br />L3 <br />L3 L3 L3 L3 L3 L3 <br />L3 <br />L3 <br />L3 <br />L3 L3 L3 <br />L3 L3 <br />L3 <br />L3 <br />L3 <br />L3L3L3 <br />L3L3L3 <br />L3L3L3 <br />X 1 <br />WP <br />SIGNAGE <br />J <br />4 A-3 <br />EM 1 <br />EM <br />1 <br />EM1 <br />OS OS 33 <br />L1 <br />EM <br />1 <br />EM <br />1 <br />X1 <br />X <br />1 <br />OS <br />D 2 <br />Dim a,b <br />A-1 <br />Dim a1 <br />A-1 <br />Dim a2 <br />A-1 <br />Dim a3 <br />A-1 <br />Dim a4 <br />A-1 <br />Dim b1 <br />A-1 <br />Dim b2 <br />A-1 <br />Dim b3 <br />D <br />A-1 <br />A-1 <br />EM <br />1 <br />A-1 A-1 <br />OS <br />EE <br />L1L1 <br />L1 <br />L1 <br />L1 <br />EE <br />2 <br />EF <br />1 <br />EF <br />15'-3" <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />SHEET TITLE: <br />DATE: SCALE: <br />AR <br />T <br />E <br /> <br />R <br />E <br />S <br />T <br />A <br />U <br />R <br />A <br />N <br />T <br /> <br />03/03/2025 <br />PLOT DATE: 10/24/2025 2:42:54 PM <br />CD <br />I <br /> <br />Ci <br />r <br />c <br />a <br /> <br />D <br />o <br />m <br />i <br />n <br />i <br /> <br />I <br />n <br />t <br />e <br />r <br />n <br />a <br />t <br />i <br />o <br />n <br />a <br />l <br />, <br /> <br />I <br />n <br />c <br />. <br />En <br />g <br />i <br />n <br />e <br />e <br />r <br />i <br />n <br />g <br /> <br />- <br /> <br />C <br />o <br />n <br />s <br />u <br />l <br />t <br />i <br />n <br />g <br />98 <br />9 <br />0 <br /> <br />R <br />e <br />s <br />e <br />a <br />r <br />c <br />h <br /> <br />D <br />r <br />. <br /> <br />S <br />u <br />i <br />t <br />e <br /> <br />1 <br />0 <br />0 <br />, <br /> <br />I <br />r <br />v <br />i <br />n <br />e <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />6 <br />1 <br />8 <br />Ph <br />o <br />n <br />e <br /> <br />( <br />9 <br />4 <br />9 <br />) <br /> <br />3 <br />3 <br />6 <br />- <br />6 <br />6 <br />3 <br />6 <br /> <br />| <br /> <br />d <br />k <br />a <br />n <br />g <br />@ <br />c <br />d <br />i <br />e <br />n <br />g <br />. <br />c <br />o <br />m <br />10 <br />9 <br /> <br />E <br /> <br />4 <br />T <br />H <br /> <br />S <br />T <br />. <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />DRAWN: CHECKED: <br />PL <br />A <br />N <br /> <br />C <br />H <br />E <br />C <br />K <br /> <br />R <br />E <br />V <br />. <br /> <br />0 <br />5 <br />/ <br />1 <br />2 <br />/ <br />2 <br />0 <br />2 <br />5 <br />FI <br />E <br />L <br />D <br /> <br />C <br />H <br />A <br />N <br />G <br />E <br /> <br />0 <br />9 <br />/ <br />0 <br />5 <br />/ <br />2 <br />0 <br />2 <br />5 <br />PL <br />A <br />N <br /> <br />C <br />H <br />E <br />C <br />K <br /> <br />R <br />E <br />V <br />. <br /> <br />0 <br />9 <br />/ <br />2 <br />9 <br />/ <br />2 <br />0 <br />2 <br />5 <br />E100 <br />1/4" = 1'-0" <br />LIGHTING PLAN <br />J.L.K.P.