Laserfiche WebLink
D-2 <br />TEA RESIDENCE <br />SHEET <br />REV DATE DESCRIPTION <br />02/22/24A <br />T H E R E S H A L L B E N O C H A N G E S O R D E V I A T I O N O N T H E S E P L A N S W I T H O U T T H E C O N S E N T O F P L A N A N D P E R M I T I N C . N O T E S A N D D E T A I L S O N T H E D R A W I N G S S H A L L T A K E P R E C E D E N C E O V E R G E N E R A L N O T E S A N D T Y P I C A L D E T A I L S . W H E R E N O D E T A I L S S H O W N O R N O T E D O N T H E D R A W I N G S , T H E D E T A I L S S H A L L B E T H E S A M E A S F O R O T H E R S I M I L A R W O R K .C O N T R A C T O R S H A L L V E R I F Y A L L P L A N S , E X I S T I N G D I M E N S I O N S A N D F I E L D C O N D I T I O N S O N T H E J O B S I T E A N D S H A L L I M M E D I A T E L Y N O T I F Y T O P L A N A N D P E R M I T I N C A N Y D I S C R E P A N C I E S I N W R I T I N G P R I O R T O T H E C O M M E N C E M E N T O F A N Y W O R K O R B E R E S P O N S I B L E F O R S A M E . <br />TH <br />E <br />S <br />E <br /> <br /> <br />D <br />E <br />S <br />I <br />G <br />N <br />S <br />, <br />D <br />R <br />A <br />W <br />I <br />N <br />G <br />S <br /> <br />A <br />N <br />D <br /> <br />S <br />P <br />E <br />C <br />I <br />F <br />I <br />C <br />A <br />T <br />I <br />O <br />N <br />S <br /> <br />A <br />R <br />E <br /> <br />T <br />H <br />E <br /> <br />P <br />R <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />A <br />N <br />D <br /> <br />C <br />O <br />P <br />Y <br />R <br />I <br />G <br />H <br />T <br /> <br />O <br />F <br /> <br />P <br />L <br />A <br />N <br /> <br />A <br />N <br />D <br /> <br />P <br />E <br />R <br />M <br />I <br />T <br /> <br />I <br />N <br />C <br /> <br />A <br />N <br />D <br /> <br />S <br />H <br />A <br />L <br />L <br /> <br />N <br />O <br />T <br /> <br />B <br />E <br /> <br />U <br />S <br />E <br />D <br /> <br />I <br />N <br /> <br />C <br />O <br />N <br />N <br />E <br />C <br />T <br />I <br />O <br />N <br /> <br />W <br />I <br />T <br />H <br /> <br />A <br />N <br />Y <br /> <br />O <br />T <br />H <br />E <br />R <br /> <br />W <br />O <br />R <br />K <br /> <br />E <br />X <br />C <br />E <br />P <br />T <br /> <br />B <br />Y <br /> <br />A <br />G <br />R <br />E <br />E <br />M <br />E <br />N <br />T <br /> <br />W <br />I <br />T <br />H <br /> <br />P <br />L <br />A <br />N <br /> <br />A <br />N <br />D <br /> <br />P <br />E <br />R <br />M <br />I <br />T <br /> <br />I <br />N <br />C <br />. <br /> <br />B <br />Y <br /> <br />U <br />S <br />I <br />N <br />G <br /> <br />T <br />H <br />E <br />S <br />E <br /> <br />P <br />L <br />A <br />N <br />S <br />, <br /> <br />T <br />H <br />E <br /> <br />U <br />S <br />E <br />R <br /> <br />A <br />G <br />R <br />E <br />E <br />S <br /> <br />T <br />O <br /> <br />R <br />E <br />L <br />E <br />A <br />S <br />E <br /> <br />P <br />L <br />A <br />N <br /> <br />A <br />N <br />D <br /> <br />P <br />E <br />R <br />M <br />I <br />T <br /> <br />I <br />N <br />C <br /> <br />F <br />R <br />O <br />M <br /> <br />A <br />N <br />Y <br /> <br />A <br />N <br />D <br /> <br />A <br />L <br />L <br /> <br />C <br />L <br />A <br />I <br />M <br />S <br />, <br /> <br />L <br />I <br />A <br />B <br />I <br />L <br />I <br />T <br />I <br />E <br />S <br />, <br /> <br />S <br />U <br />I <br />T <br />S <br />, <br /> <br />A <br />N <br />D <br /> <br />D <br />E <br />M <br />A <br />N <br />D <br />S <br /> <br />O <br />N <br /> <br />A <br />C <br />C <br />O <br />U <br />N <br />T <br /> <br />O <br />F <br /> <br />A <br />N <br />Y <br /> <br />I <br />N <br />J <br />U <br />R <br />Y <br />, <br /> <br />D <br />A <br />M <br />A <br />G <br />E <br /> <br />O <br />R <br /> <br />L <br />O <br />S <br />S <br /> <br />O <br />R <br /> <br />P <br />E <br />R <br />S <br />O <br />N <br />S <br /> <br />O <br />R <br /> <br />P <br />R <br />O <br />P <br />E <br />R <br />T <br />Y <br />, <br /> <br />I <br />N <br />C <br />L <br />U <br />D <br />I <br />N <br />G <br /> <br />I <br />N <br />J <br />U <br />R <br />Y <br /> <br />O <br />R <br /> <br />D <br />E <br />A <br />T <br />H <br />, <br /> <br />O <br />R <br /> <br />E <br />C <br />O <br />N <br />O <br />M <br />I <br />C <br /> <br />L <br />O <br />S <br />S <br />E <br />S <br />, <br /> <br />A <br />R <br />I <br />S <br />I <br />N <br />G <br /> <br />O <br />U <br />T <br /> <br />O <br />F <br /> <br />T <br />H <br />E <br /> <br />U <br />S <br />E <br /> <br />O <br />F <br /> <br />T <br />H <br />E <br />S <br />E <br /> <br />P <br />L <br />A <br />N <br />S <br />. <br />03/04/24B SKETCH FOR APPROVAL <br />SKETCH FOR REVIEW <br />90PD FOR REVIEWD <br />90PD FOR APPROVAL <br />G 100PD FOR SUBMITTAL <br />E <br />PROPERTY ADDRESS: <br />2233 W HALL AVE, <br />SANTA ANA, CA 92704 <br />PLAN AND PERMIT INC. <br />ARCHITECTURAL DESIGN SERVICES <br />9891 IRVINE CENTER DR #200 <br />IRVINE, CA 92618 <br />(714)-715-0923 <br />biz@planandpermit.com <br />LOCATION QR CODE: <br />STATE OF CAL IFORNIA <br />EXP. DATE <br />L <br />I <br />C <br />E <br />NS E D A R C H <br />I <br />T <br />E <br />C <br />T <br />C - 34643 <br />06/30/2027 <br />SIGNATURE <br />PAUL SAN GEMINO <br />04/18/24 <br />04/24/24 <br />07/24/24 <br />03/18/24C SKETCH FOR APPROVAL <br />PER STRUCTURALF05/23/24 <br />10/29/24 PER PLANNINGH <br />02/11/25PC1 <br />10/05/25 REV11 <br />CITY COMMENTS <br />DETAILS <br />CONCRETE FOOTING <br />GROUNDING ELECTRODE: <br />MIN. 20' #4 REBAR <br />BOND TO METAL COLD WATER PIPING <br />LISTED SYSTEM GROUND CLAMPS <br />LISTED SYSTEM GROUND CLAMPS <br />GROUNDED (NEUTRAL) SERVICE CONDUCTOR <br />GROUNDING ELECTRODE CONDUCTOR MIN. #4 <br />AWG BARE COPPER WIRE (PROTECTED) <br />PULL SECTION <br />IF NEUTRAL BUS IS INSULATED FROM THE <br />ENCLOSURE, INSTALL A MAIN BONDING <br />JUMPER OR SCREW WITH A GREEN FINISH. <br />DISCONNECT SECTION <br />METER <br />ELECTRICAL SERVICE ENTRANCE PANEL <br />1 N.T.S. <br />UFER GROUND DETAIL (OR APPROVED EQUAL) <br />3' <br />DRYER VENT <br />EXHAUST DUCT TERMINATION (502.2.1) <br />·SHALL TERMINATE TO THE OUTSIDE OF THE BUILDING <br />·EQUIPPED WITH A BACKDRAFT DAMPER <br />·NO SCREENS SHALL BE INSTALLED AT DUCT TERMINATION. <br />·NO DEVICE SUCH AS FIRE OR SMOKE DAMPERS THAT WILL <br />OBSTRUCT THE FLOW OF EXHAUST SHALL BE INSTALLED <br />TRANSITION DUCT <br />(504.4.2.2) <br />·LISTED AND LABELED IN <br />ACCORDANCE WITH UL 2158A <br />·SHALL BE A SINGLE LENGTH OF 6' <br />MAX. <br />·ONLY BETWEEN TYPE 1 DRYER <br />AND EXHAUST DUCT <br />·SHALL NOT BE CONCEALED <br />WITHIN CONSTRUCTION. <br />EXHAUST DUCT - TYPE 1 (504.4.2) <br />·MIN 0.016 INCH IN THICKNESS <br />·MIN 4" NOMINAL DIAMETER <br />·NOT TO EXCEED TOTAL COMBINED HORIZONTAL AND VERTICAL LENGTH OF 14', <br />INCLUDING TWO 90° ELBOWS. A LENGTH OF 2' SHALL BE DEDUCTED FOR EACH <br />90° ELBOW IN EXCESS OF TWO. <br />·DUCTS SHALL BE SUPPORTED IN ACCORDANCE WITH SMACNA HVAC DUCT <br />CONSTRUCTION STANDARDS - METAL AND FLEXIBLE <br />EXHAUST DUCT - TYPE 2 (504.4.3.2) <br />·CONSTRUCTED OF SHEET METAL OR OTHER NONCOMUBSTIBLE MATERIAL <br />EQUIVALENT IN STRENGTH AND CORROSION RESISTANCE TO GALVANIZED SHEET STEEL <br />NOT LESS THAN 0.0195 INCH THICK. <br />·EQUIPPED OR INSTALLED WITH LINT-CONTROLLING MEANS . <br />·INSTALLED WITH MINIMUM CLEARANCE OF 6" FROM ADJACENT COMBUSTIBLE <br />MATERIAL <br />·WHEN PASSING THROUGH WALLS, FLOOR, OR PARTITIONS, THE SPACE AROUND THE <br />DUCT SHALL BE SEALED WITH NONCOMBUSTIBLE MATERIAL. [NFPA 54: 10.4.5.5.] <br />COMMON EXHAUST DUCT (504.4.4) <br />WHERE PERMITTED BY MANUFACTURER'S INSTALLATION INSTRUCTIONS, <br />MULTIPLE CLOTHES DRYER SHALL BE PERMITTED TO BE INSTALLED WITH A <br />COMMON EXHAUST. <br />·SHALL BE CONSTRUCTED OF 24 GAUGE RIGID METAL (MIN. 0.020" <br />THICK) <br />·INSTALLED IN A FIRE RESISTANT RATED ENCLOSURE. <br />·ENCLOSURE SHALL BE PROVIDED WITH A CLEANOUT OPENING <br />AT THE BASE. MIN 12" x 12" <br />·EXHAUST FAN LOCATED DOWNSTREAM OF BRANCH <br />CONNECTIONS, OPERATED CONTINUOUSLY AND MONITORED BY <br />AN APPROVED MEANS. <br />CLOTHES WASHER <br />STANDPIPE <br />CLOTHES WASHER CONNECTION <br />N.T.S. <br />CLOTHES WASHER <br />DRAIN HOSE <br />INDIRECT CONNECTION <br />TRAP <br />WASTE STACK <br />WINDOW <br />DUCT TERMINATION <br />DUCT TERMINATIONS SHALL BE: <br />·3FT FROM PROPERTY LINE <br />·10FT MIN. FROM A FORCED AIR INLET <br />·3FT FROM OPENINGS INTO THE BUILDING <br />STEEL NAIL PLATE (316.6) <br />WHEN THE DUCT PENETRATES FRAMING MEMBERS TO WITHIN 1 <br />INCH OF THE EXPOSED FRAMING, STEEL NAIL PLATES, MIN. 18 <br />GAUGE IN THICKNESS, SHALL BE INSTALLED EXTENDING NOT LESS <br />THAN 1-1/2" BEYOND THE OUTSIDE DIAMETER OF THE DUCT. <br />1-1/2" <br /><1" <br />3/ <br />4 <br />" <br /> <br />MI <br />N <br />. <br /> <br />C <br />E <br />I <br />L <br />I <br />N <br />G <br /> <br />H <br />E <br />I <br />G <br />H <br />T <br /> <br />P <br />E <br />R <br /> <br />B <br />C <br /> <br />C <br />h <br /> <br />1 <br />2 <br />. <br />VENT TO <br />OUTDOOR <br />R90° ELBOW FITTING <br />CLOTHES DRYER EXHAUST3 N.T.S.2 <br />3' <br />FOUNDATION VENT <br />DUCT TERMINATION <br />DUCT TERMINATIONS SHALL BE: <br />·3' MIN FROM PROPERTY LINE <br />·10' FROM A FORCED AIR INLET <br />·10' ABOVE A PUBLIC WALKWAY <br />·3' FROM OPENINGS INTO THE BUILDING <br />7 548 <br />N.T.S. <br />INTERIOREXTERIOR <br />VENT FLANGE <br />VENT HOOD <br />APPLY URETHANE FOAM <br />SEALANT AROUND DUCT/PIPE <br />PENETRATION AT INSULATING <br />SHEATHING <br />EXTEND EXISTING DUCT/PIPE <br />IF WALL AIR CONTROL LAVER IS NOT <br />A FULLY-ADHERED MATERIAL, BED <br />IN A CONTINUOUS BEAD OF <br />SEALANT AROUND THE PERIMETER <br />OF THE SHEATHING PENETRATION <br />TAPE ALL SEAMS OF OUTERMOST <br />LAYER OF INSULATING SHEATHING <br />WITH COMPATIBLE SHEATHING TAPE <br />TO FORM WATER CONTROL LAYER <br />HOUSEWRAP WITH ALL SEAMS TAPED <br />AND EDGES SEALED, APPLIED OVER <br />EXISTING WALL SHEATHING TO FORM <br />CONTINUOUS AIR CONTROL LAYER. <br />OR <br />FULLY-ADHERED OR LIQUID APPLIED AIR <br />CONTROL MEMBRANE APPLIED OVER <br />EXISTING WALL SHEATHING TO FORM <br />CONTINUOUS AIR CONTROL LAYER <br />PIPE PENETRATION. TYP. <br />BLOCKING AS REQUIRED <br />(E) PARTITION <br />(E) SHEATHING <br />(2) LAYERS BUILDING PAPER <br />(WEATHER-RESISTANT TYPE <br />1 GRADE D STYLE 2) <br />GALVANIZED METAL LATH <br />6 N.T.S. <br />WINDOW <br />ROUGH OPENING <br />STEP 1 <br />LINTEL <br />STEP 2 STEP 3 STEP 4 <br />A <br />B <br />C <br />WINDOW FLASHING DETAIL <br />ATTACH A SILL STRIP OF ASPHALT- SATURATED ROOFING FELT PAPER, OR APPROVED <br />FLASHING MATERIAL AT LEAST 8" WIDE WITH THE TOP EDGE EVEN WITH THE TOP EDGE <br />OF THE ROUGH SILL. EXTEND THIS SILL STRIP AT LEAST 8" BEYOND THE EDGE OF THE <br />ROUGH OPENING OF THE WINDOW. <br />AFTER SILL STRIP IS IN PLACE, ATTACH JAMB STRIP (SIDE OF OPENING) AT LEAST 8" <br />WIDE WITH INSIDE EDGE EVEN WITH EDGE OF WINDOW OPENING. EXTEND JAMB <br />STRIP 4" ABOVE THE TOP OF WINDOW OPENING. <br />APPLY A BEAD OF CAULKING TO THE BACK SURFACES OF THE WINDOW, THEN PLACE THE <br />WINDOW INTO THE ROUGH OPENING, WITH FLANGES OVER THE INSTALLED FLASHING <br />FELT STRIP. AFTER WINDOW IS PLACED, INSTALL THE HEAD FLASHING OVER THE <br />WINDOW FLANGE. THIS IS ANOTHER STRIP OF FELT AT LEAST 4" WIDE. <br />STARTING AT THE BOTTOM OF THE WALL (SOLE PLATE), LAY WATER RESISTANT PAPER UNDER <br />THE SILL STRIP AND CUT TO FIT (A) INSTALL SUCCEEDING COURSES OF WATER RESISTANT <br />PAPER (B,C, ETC.) OVER JAMB AND HEAD FLANGES IN SHINGLE BOARD FASHION. <br />4 <br />MOLDING HATCH DOOR FRAMING <br />MOLDING HATCH DOOR FRAMING <br />ATTIC ACCESS DETAIL <br />GWB 1" RIGID INSULATION <br />SHEATH INTERIOR OF ATTIC ACCESS <br />TO +1" OF INSULATION LEVEL <br />N.T.S. <br />5 N.T.S. <br />GWB <br />ATTIC ACCESS DETAIL