My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
922 W Park Ln - Plan
PBA
>
Building
>
ProjectDox
>
P
>
Park Ln
>
922 W Park Ln
>
922 W Park Ln - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:02:30 AM
Creation date
2/13/2026 5:00:26 AM
Metadata
Fields
Template:
Plan
Permit Number
101124745
Full Address
922 W Park Ln
Street Number
922
Street Direction
W
Street Name
Park
Street Suffix
Ln
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) [Group] <br />Member Reaction (lbs)1264 @ 2"4922 (2.25")Passed (26%)--1.0 D + 1.0 Lr (Alt Spans) [5] <br />Shear (lbs)1052 @ 1' 3/4"4856 Passed (22%)1.25 1.0 D + 1.0 Lr (Alt Spans) [5] <br />Moment (Ft-lbs)3533 @ 6' 1/16"5615 Passed (63%)1.25 1.0 D + 1.0 Lr (Alt Spans) [5] <br />Live Load Defl. (in)0.157 @ 6' 7 1/8"0.438 Passed (L/999+)--1.0 D + 1.0 Lr (Alt Spans) [5] <br />Total Load Defl. (in)0.298 @ 6' 7 1/4"0.657 Passed (L/530)--1.0 D + 1.0 Lr (Alt Spans) [5] <br />Member Length : 14' 2 1/2" <br />System : Roof <br />Member Type : Flush Beam <br />Building Use : Residential <br />Building Code : IBC 2021 <br />Design Methodology : ASD <br />Member Pitch : 0/12 <br />•Deflection criteria: LL (L/360) and TL (L/240). <br />•Overhang deflection criteria: LL (2L/360) and TL (2L/240). <br />•Applicable calculations are based on NDS. <br />• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. <br />• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br />Bearing Length Loads to Supports (lbs) <br />Supports Total Available Required Dead Roof Live Wind Factored Accessories <br />1 - Column - DF 3.50"2.25"1.50"601 686 147/-1 1287 1 1/4" Rim Board <br />2 - Column - DF 3.50"3.50"1.50"537 580 -462 1116 Blocking <br />Lateral Bracing Bracing Intervals Comments <br />Top Edge (Lu)Continuous <br />Bottom Edge (Lu)End Bearing Points <br />• Side loads are assumed to not induce cross-grain tension. <br />Dead Roof Live Wind <br />Vertical Loads Location (Side)Tributary <br />Width <br />(0.90)(1.25)(1.60)Comments <br />0 - Self Weight (PLF)1 1/4" to 14' 3 3/4"N/A 8.2 ---- <br />1 - Uniform (PLF)0 to 14' 3 3/4" (Front)N/A 6.8 21.0/-9.8 25.5/-36.0 Linked from: <br />(N)RR4, Support 3 <br />2 - Uniform (PLF)5' 6" to 14' 3 3/4" (Front)N/A 50.3 48.0 -48.0 Linked from: <br />(N)RR6, Support 2 <br />3 - Uniform (PLF)0 to 5' 6" (Front)N/A 87.5 98.3 115.5 Linked from: <br />(N)RR7, Support 2 <br />Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties <br />related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is <br />responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at <br />Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br />and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ <br />document-library. <br />The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator <br />Weyerhaeuser Notes <br />Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). <br />MEMBER REPORT PASSED <br />Roof, (N)RB15 <br />1 piece(s) 4 x 10 DF No.2 <br />Page 103 of 290
The URL can be used to link to this page
Your browser does not support the video tag.