Laserfiche WebLink
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) <br />Member Reaction (lbs)2046 @ 2' 5"8177 (3.50")Passed (25%)--1.0 D + 1.0 Lr (All Spans) <br />Shear (lbs)980 @ 3' 3 7/16"4856 Passed (20%)1.25 1.0 D + 1.0 Lr (All Spans) <br />Moment (Ft-lbs)2130 @ 7' 10 5/8"5615 Passed (38%)1.25 1.0 D + 1.0 Lr (Alt Spans) <br />Live Load Defl. (in)0.043 @ 0 0.200 Passed (2L/999+)--1.0 D + 0.6 W (Alt Spans) <br />Total Load Defl. (in)0.154 @ 8' 2 1/4"0.620 Passed (L/964)--1.0 D + 1.0 Lr (Alt Spans) <br />Member Length : 15' 3 3/16" <br />System : Roof <br />Member Type : Flush Beam <br />Building Use : Residential <br />Building Code : IBC 2021 <br />Design Methodology : ASD <br />Member Pitch : 4.5/12 <br />•Deflection criteria: LL (L/360) and TL (L/240). <br />•Overhang deflection criteria: LL (0.2") and TL (2L/240). <br />•Applicable calculations are based on NDS. <br />• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br />• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger <br />• ¹ See Connector grid below for additional information and/or requirements. <br />Bearing Length Loads to Supports (lbs) <br />Supports Total Available Required Dead Roof Live Wind Factored Accessories <br />1 - Column - DF 3.50"3.50"1.50"1085 961 -961 2046 Blocking <br />2 - Hanger on 9 1/4" DF beam 3.50"Hanger¹1.50"286 281 39/-302 567/-10 See note ¹ <br />•Dimensions for lateral bracing intervals are measured along the length of the member for sloped conditions. <br />Lateral Bracing Bracing Intervals Comments <br />Top Edge (Lu)Continuous <br />Bottom Edge (Lu)End Bearing Points <br />Connector: Simpson Strong-Tie <br />Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories <br />2 - Face Mount Hanger LSSR410Z 1.88"N/A 22-16dx2.5 18-16dx2.5 <br />•Refer to manufacturer notes and instructions for proper installation and use of all connectors. <br />• Distributed wind loads are applied perpendicular to the slope of the member. <br />• Side loads are assumed to not induce cross-grain tension. <br />Dead Roof Live Wind <br />Vertical Loads Location (Side)Tributary <br />Width <br />(0.90)(1.25)(1.60)Comments <br />0 - Self Weight (PLF)0 to 14' 1/4"N/A 8.2 ---- <br />1 - Tapered (PSF)0 to 9'11' to 3'16.0 16.0 -16.0 ROOF LOAD <br />2 - Tapered (PSF)9' to 14' 3 3/4"5' to 0 12.0 16.0 -16.0 ROOF LOAD <br />Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties <br />related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is <br />responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at <br />Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br />and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ <br />document-library. <br />The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator <br />Weyerhaeuser Notes <br />Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). <br />MEMBER REPORT PASSED <br />Roof, (N)VB1 <br />1 piece(s) 4 x 10 DF No.2 <br />Page 104 of 290